scholarly journals Non-destructive mid-IR spectroscopy with quantum cascade laser can detect ethylene gas dynamics of apple cultivar ‘Fuji’ in real time

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Masaki Yumoto ◽  
Yasushi Kawata ◽  
Tetsuya Abe ◽  
Tomoki Matsuyama ◽  
Satoshi Wada

AbstractMany plants, including fruits and vegetables, release biogenic gases containing various volatile organic compounds such as ethylene (C2H4), which is a gaseous phytohormone. Non-destructive and in-situ gas sampling technology to detect trace C2H4 released from plants in real time would be attractive for visualising the ageing, ripening, and defence reactions of plants. In this study, we developed a C2H4 detection system with a detection limit of 0.8 ppb (3σ) using laser absorption spectroscopy. The C2H4 detection system consists of a mid-infrared quantum cascade laser oscillated at 10.5 µm, a multi-pass gas cell, a mid-IR photodetector, and a gas sampling system. Using non-destructive and in-situ gas sampling, while maintaining the internal pressure of the multi-pass gas cell at low pressure, the change in trace C2H4 concentration released from apples (Malus domestica Borkh.) can be observed in real time. We succeeded in observing C2H4 concentration changes with a time resolution of 1 s, while changing the atmospheric gas and surface temperature of apples from the ‘Fuji’ cultivar. This technique allows the visualisation of detailed C2H4 dynamics in plant environmental response, which may be promising for further progress in plant physiology, agriculture, and food science.

2014 ◽  
Vol 7 (1) ◽  
pp. 81-93 ◽  
Author(s):  
D. J. Miller ◽  
K. Sun ◽  
L. Tao ◽  
M. A. Khan ◽  
M. A. Zondlo

Abstract. We demonstrate a compact, open-path, quantum cascade-laser-based atmospheric ammonia sensor operating at 9.06 μm for high-sensitivity, high temporal resolution, ground-based measurements. Atmospheric ammonia (NH3) is a gas-phase precursor to fine particulate matter, with implications for air quality and climate change. Currently, NH3 sensing challenges have led to a lack of widespread in situ measurements. Our open-path sensor configuration minimizes sampling artifacts associated with NH3 surface adsorption onto inlet tubing and reduced pressure sampling cells, as well as condensed-phase partitioning ambiguities. Multi-harmonic wavelength modulation spectroscopy allows for selective and sensitive detection of atmospheric pressure-broadened absorption features. An in-line ethylene reference cell provides real-time calibration (±20% accuracy) and normalization for instrument drift under rapidly changing field conditions. The sensor has a sensitivity and noise-equivalent limit (1σ) of 0.15 ppbv NH3 at 10 Hz, a mass of ~ 5 kg and consumes ~ 50 W of electrical power. The total uncertainty in NH3 measurements is 0.20 ppbv NH3 ± 10%, based on a spectroscopic calibration method. Field performance of this open-path NH3 sensor is demonstrated, with 10 Hz time resolution and a large dynamic response for in situ NH3 measurements. This sensor provides the capabilities for improved in situ gas-phase NH3 sensing relevant for emission source characterization and flux measurements.


The Analyst ◽  
2014 ◽  
Vol 139 (9) ◽  
pp. 2047 ◽  
Author(s):  
Mark C. Phillips ◽  
Matthew S. Taubman ◽  
Bruce E. Bernacki ◽  
Bret D. Cannon ◽  
Robert D. Stahl ◽  
...  

2019 ◽  
Vol 48 (10) ◽  
pp. 1010001
Author(s):  
唐峰 TANG Feng ◽  
刘顺桂 LIU Shun-gui ◽  
吕启深 L Qi-shen ◽  
李新田 LI Xin-tian ◽  
赫树开 HE Shu-kai ◽  
...  

2018 ◽  
Vol 47 (4) ◽  
pp. 423001
Author(s):  
LIN Bai-yang ◽  
DANG Jing-min ◽  
ZHENG Chuan-tao ◽  
ZHANG Yu ◽  
WANG Yi-ding

2019 ◽  
Vol 58 (SC) ◽  
pp. SC1013
Author(s):  
Daisuke Hayashi ◽  
Yoko Sato ◽  
Masakazu Minami ◽  
Noboru Muramatsu ◽  
Motoaki Iwaya

2018 ◽  
Vol 232 ◽  
pp. 04053
Author(s):  
Cheng-xing Miao ◽  
Qing Li ◽  
Sheng-yao Jia

In order to get ridded of the non real-time detection methods of artificial site sampled and laboratory instrument analyzed in the field of methane detection in the offshore shallow gas, real-time in-situ detection system for methane in offshore shallow gas was designed by the film interface.The methane in the offshore shallow gas through the gas-liquid separation membrane of polymer permeation into the system internal detection probe, analog infrared micro gas sensor sensed the methane concentration and the corresponded output value, data acquisition and communication node fitted into standard gas concentration.Based on the experimental data compared with the traditional detection method, and further analyzed the causes of error produced by the case experiment. The application results show that the system can achieve a single borehole layout, long-term on-line in-situ on-line detection, and improve the detection efficiency and the timeliness of the detection data.


Sign in / Sign up

Export Citation Format

Share Document