scholarly journals Effects of endothelial defects and venous interposition grafts on the acute incidence of thrombus formation within microvascular procedures

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Lucas M. Ritschl ◽  
Marie-Kristin Hofmann ◽  
Constantin T. Wolff ◽  
Leonard H. Schmidt ◽  
Klaus-Dietrich Wolff ◽  
...  

AbstractEndothelial defects (ED) and the usage of interposition vein grafts (IVG) are known risk factors for free flap failure. This experimental study aimed to compare both situations of thrombus formation and fluorescence angiographic behavior. Indocyanine green videoangiography (ICGVA) with the FLOW 800 tool was systematically performed in groups I = ED, II = IVG, and III = ED and IVG (each n = 11). ICGVA was able to detect thrombosis in five animals and safely ruled it out in 26 with two false-positive cases (sensitivity, specificity, and positive and negative predictive values were 100%, 90%, 62%, and 100%, respectively). The difference between visually and ICGVA-assisted ED measurements was significant (p = 0.04). The areas of thrombosis showed no significant difference. Moreover, ICGVA detected a decrease of all parameters at the ED area and/or within the IVG section in all groups. The presence of an endothelial defect had a higher impact on thrombus formation than the IVG usage. ICGVA is qualitatively able to detect endothelial defects and clinically evident thrombosis. However, the quantitative values are not yet attributable to one of the clinical scenarios that may jeopardize free flap transfer.

2016 ◽  
Vol 45 (2) ◽  
pp. 76
Author(s):  
Suprawita Sari ◽  
Supriatmo Supriatmo ◽  
S L Margaretha ◽  
S Nafianti ◽  
B Hasibuan ◽  
...  

Objective To evaluate the diagnostic accuracy and agreementbetween the 1980 and 1990 WHO criteria for determining the de-gree of dehydration in children with acute diarrhea.Methods This prospective study was conducted in two hospitalsfrom October 2002 to February 2003. Clinical signs of dehydrationall patients were recorded. The degree of dehydration based onthe 1980 and 1990 WHO criteria was determined and comparedwith fluid deficit measured by the difference of body weight on ad-mission and on discharge. Chi-square test and kappa value analy-ses were performed. Sensitivity, specificity, predictive values, andaccuracy of each WHO criteria were assessed. The prevalence ofdehydration was also determined.Results Sixty-five patients, comprising 40 boys and 25 girls, werestudied. There was a significant difference between the two WHOcriteria in differentiating between dehydration and non-dehydra-tion (P<0.05). Based on the 1980 WHO criteria the prevalence ofdehydration was 62.2%. Its sensitivity, specificity, and accuracy indiagnosing dehydration were 100.0%, 55.5%, and 86.2%, respec-tively. Based on the 1990 WHO criteria, the prevalence of dehy-dration was 60.0%. Its sensitivity, specificity, and accuracy in diag-nosing dehydration were 94.9%, 46.1%, and 75.4%, respectively.There was also a significant difference between both criteria indetermining severe dehydration (P<0.05). Based on the 1980 cri-teria, the prevalence of severe dehydration was 15.4%. Its sensi-tivity, specificity, and accuracy in diagnosing severe dehydrationwere 30.0%, 94.5%, and 84.6%, respectively. Based on the 1990criteria, these results were 40.0%, 94.5%, and 86.2%, respectively.The prevalence was 15.4%. Kappa value comparing the two WHOcriteria was 0.852 in diagnosing dehydration and 0.915 in diag-nosing severe dehydration. There was no significant differencebetween the two criteria in their sensitivity and specificity (P>0.05).Conclusion Both WHO criteria can be applied to determine de-hydration in patients with acute diarrhea, although we feel that the1990 criteria is simpler


1983 ◽  
Vol 10 (1) ◽  
pp. 21-36 ◽  
Author(s):  
Douglas H. Harrison ◽  
Marjorie Girling ◽  
Godfrey Mott

Author(s):  
George A. Beyer ◽  
Karan Dua ◽  
Neil V. Shah ◽  
Joseph P. Scollan ◽  
Jared M. Newman ◽  
...  

Abstract Introduction We evaluated the demographics, flap types, and 30-day complication, readmission, and reoperation rates for upper extremity free flap transfers within the National Surgical Quality Improvement Program (NSQIP) database. Materials and Methods Upper extremity free flap transfer patients in the NSQIP from 2008 to 2016 were identified. Complications, reoperations, and readmissions were queried. Chi-squared tests evaluated differences in sex, race, and insurance. The types of procedures performed, complication frequencies, reoperation rates, and readmission rates were analyzed. Results One-hundred-eleven patients were selected (mean: 36.8 years). Most common upper extremity free flaps were muscle/myocutaneous (45.9%) and other vascularized bone grafts with microanastomosis (27.9%). Thirty-day complications among all patients included superficial site infections (2.7%), intraoperative transfusions (7.2%), pneumonia (0.9%), and deep venous thrombosis (0.9%). Thirty-day reoperation and readmission rates were 4.5% and 3.6%, respectively. The mean time from discharge to readmission was 12.5 days. Conclusion Upper extremity free flap transfers could be performed with a low rate of 30-day complications, reoperations, and readmissions.


2020 ◽  
pp. 1-2
Author(s):  
Michael Alperovich ◽  
Eric Park ◽  
Michael Alperovich ◽  
Omar Allam ◽  
Paul Abraham

Although sickle cell disease has long been viewed as a contraindication to free flap transfer, little data exist evaluating complications of microsurgical procedures in the sickle cell trait patient. Reported is the case of a 55-year-old woman with sickle cell trait who underwent a deep inferior epigastric perforator (DIEP) microvascular free flap following mastectomy. The flap developed signs of venous congestion on postoperative day two but was found to have patent arterial and venous anastomoses upon exploration in the operating room. On near-infrared indocyanine green angiography, poor vascular flow was noted despite patent anastomoses and strong cutaneous arterial Doppler signals. Intrinsic microvascular compromise or sickling remains a risk in the sickle cell trait population as it does for the sickle cell disease population. Just like in sickle cell disease patients, special care should be taken to optimize anticoagulation and minimize ischemia-induced sickling for patients with sickle cell trait undergoing microsurgery.


Author(s):  
Giuseppe Vetrugno ◽  
Daniele Ignazio La Milia ◽  
Floriana D’Ambrosio ◽  
Marcello Di Pumpo ◽  
Roberta Pastorino ◽  
...  

Healthcare workers are at the forefront against COVID-19, worldwide. Since Fondazione Policlinico Universitario A. Gemelli (FPG) IRCCS was enlisted as a COVID-19 hospital, the healthcare workers deployed to COVID-19 wards were separated from those with limited/no exposure, whereas the administrative staff were designated to work from home. Between 4 June and 3 July 2020, an investigation was conducted to evaluate the seroprevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) immunoglobulin (IgG) antibodies among the employees of the FPG using point-of-care (POC) and venous blood tests. Sensitivity, specificity, and predictive values were determined with reverse-transcription polymerase chain reaction on nasal/oropharyngeal swabs as the diagnostic gold standard. The participants enrolled amounted to 4777. Seroprevalence was 3.66% using the POC test and 1.19% using the venous blood test, with a significant difference (p < 0.05). The POC test sensitivity and specificity were, respectively, 63.64% (95% confidence interval (CI): 62.20% to 65.04%) and 96.64% (95% CI: 96.05% to 97.13%), while those of the venous blood test were, respectively, 78.79% (95% CI: 77.58% to 79.94%) and 99.36% (95% CI: 99.07% to 99.55%). Among the low-risk populations, the POC test’s predictive values were 58.33% (positive) and 98.23% (negative), whereas those of the venous blood test were 92.86% (positive) and 98.53% (negative). According to our study, these serological tests cannot be a valid alternative to diagnose COVID-19 infection in progress.


Author(s):  
W. Leontiev ◽  
E. Magni ◽  
C. Dettwiler ◽  
C. Meller ◽  
R. Weiger ◽  
...  

Abstract Objectives The aim of the present study was to compare the accuracy of the conventional illumination method (CONV) and the fluorescence-aided identification technique (FIT) for distinguishing between composite restorations and intact teeth using different fluorescence-inducing devices commonly used for FIT. Materials and methods Six groups of six dentists equipped with one of six different FIT systems each independently attempted to identify composite restorations and intact teeth on a full-mouth model with 22 composite restorations using CONV and, 1 h later, FIT. The entire procedure was repeated 1 week later. Sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values, including 95% confidence intervals (CI), were calculated for CONV and FIT overall and for each device. The influence of examiner age, method, and device on each parameter was assessed by multivariate analysis of variance. Results The sensitivity (84%, CI 81–86%), specificity (94%, CI 93–96%), PPV (92%, CI 90–94%), and NPV (90%, CI 88–91%) of FIT was significantly higher than that of CONV (47%, CI 44–50%; 82%, CI 79–84%; 66%, CI 62–69%, and 69%, CI 68–71%, respectively; p<0.001). The differences between CONV and FIT were significant for all parameters and FIT systems except VistaCam, which achieved no significant difference in specificity. Examiners younger than 40 years attained significantly higher sensitivity and negative predictive values than older examiners. Conclusions FIT is more reliable for detecting composite restorations than the conventional illumination method. Clinical relevance FIT can be considered an additional or alternative tool for improving the detection of composite restorations.


2018 ◽  
Vol 6 (11) ◽  
pp. e1913 ◽  
Author(s):  
Mohammad S. Radwan ◽  
Ammar Z. Barakat ◽  
Mohammad M. Jaber ◽  
Ashraf A. Mashal

Microsurgery ◽  
1984 ◽  
Vol 5 (2) ◽  
pp. 102-104 ◽  
Author(s):  
Leonard K. Ruby ◽  
Mark Greene ◽  
Giovanni Risitand ◽  
Ricardo Torrejon ◽  
Mark R. Belsky

Microsurgery ◽  
1992 ◽  
Vol 13 (4) ◽  
pp. 208-213 ◽  
Author(s):  
Xiaolu Li ◽  
Brian C. Cooley ◽  
Suzann M. Gruel ◽  
Zhong Ye ◽  
John S. Gould

Sign in / Sign up

Export Citation Format

Share Document