scholarly journals Delayed neutralizing antibody response in the acute phase correlates with severe progression of COVID-19

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Hitoshi Kawasuji ◽  
Yoshitomo Morinaga ◽  
Hideki Tani ◽  
Miyuki Kimura ◽  
Hiroshi Yamada ◽  
...  

AbstractAdaptive immunity to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) dynamics remain largely unknown. The neutralizing antibody (NAb) levels in patients with coronavirus disease 2019 (COVID-19) are helpful for understanding the pathology. Using SARS-CoV-2 pseudotyped virus, serum sample neutralization values in symptomatic COVID-19 patients were measured using the chemiluminescence reduction neutralization test (CRNT). At least two sequential serum samples collected during hospitalization were analyzed to assess NAbs neutralizing activity dynamics at different time points. Of the 11 patients, four (36.4%), six (54.5%), and one (9.1%) had moderate, severe, and critical disease, respectively. Fifty percent neutralization (N50%-CRNT) was observed upon admission in 90.9% (10/11); all patients acquired neutralizing activity 2–12 days after onset. In patients with moderate disease, neutralization was observed at earliest within two days after symptom onset. In patients with severe-to-critical disease, neutralization activity increased, plateauing 9–16 days after onset. Neutralization activity on admission was significantly higher in patients with moderate disease than in patients with severe-to-critical disease (relative % of infectivity, 6.4% vs. 41.1%; P = .011). Neutralization activity on admission inversely correlated with disease severity. The rapid NAb response may play a crucial role in preventing the progression of COVID-19.

2021 ◽  
Author(s):  
Hitoshi Kawasuji ◽  
Yoshitomo Morinaga ◽  
Hideki Tani ◽  
Miyuki Kimura ◽  
Hiroshi Yamada ◽  
...  

AbstractIntroductionAdaptive immunity to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) dynamics remain largely unknown. The neutralizing antibody (NAb) levels in patients with coronavirus disease 2019 (COVID-19) are helpful for understanding the pathology.Patients and MethodsUsing SARS-CoV-2 pseudotyped virus, serum sample neutralization values in symptomatic COVID-19 patients were measured using the chemiluminescence reduction neutralization test (CRNT). At least two sequential serum samples collected during hospitalization were analyzed to assess NAbs neutralizing activity dynamics at different time points.ResultsOf the 11 patients, four (36.4%), six (54.5%), and one (9.1%) had moderate, severe, and critical disease, respectively. Fifty percent neutralization (N50%-CRNT) was observed upon admission in 90.9% (10/11); all patients acquired neutralizing activity 2–12 days after onset. In patients with moderate disease, neutralization was observed at earliest within two days after symptom onset. In patients with severe-to-critical disease, neutralization activity increased, plateauing 9–16 days after onset. Neutralization activity on admission was significantly higher in patients with moderate disease than in patients with severe-to-critical disease (relative % of infectivity, 6.4% vs. 41.1%; P=.0011).ConclusionsNeutralization activity on admission inversely correlated with disease severity. The rapid NAb response may play a crucial role in preventing the progression of COVID-19.


2020 ◽  
Vol 222 (10) ◽  
pp. 1620-1628 ◽  
Author(s):  
Steven B Bradfute ◽  
Ivy Hurwitz ◽  
Alexandra V Yingling ◽  
Chunyan Ye ◽  
Qiuying Cheng ◽  
...  

Abstract Background Convalescent plasma (CP) is a potentially important therapy for coronavirus disease 2019 (COVID-19). However, knowledge regarding neutralizing antibody (NAb) titers in donor plasma and their impact in patients with acute COVID-19 remains largely undetermined. We measured NAb titers in CP and in patients with acute COVID-19 before and after transfusion through the traditional Food and Drug Administration investigational new drug pathway. Methods We performed a single-arm interventional trial measuring NAb and total antibody titers before and after CP transfusion over a 14-day period in hospitalized patients with laboratory-confirmed severe acute respiratory syndrome coronavirus 2 infection. Results NAb titers in the donor CP units were low (<1:40 to 1:160) and had no effect on recipient neutralizing activity 1 day after transfusion. NAb titers were detected in 6 of 12 patients on enrollment and in 11 of 12 at ≥2 time points. Average titers peaked on day 7 and declined toward day 14 (P = .004). Nab titers and immunoglobulin G levels were correlated in donor plasma units (ρ = 0.938; P < .001) and in the cumulative patient measures (ρ = 0.781; P < .001). Conclusions CP infusion did not alter recipient NAb titers. Prescreening of CP may be necessary for selecting donors with high titers of neutralizing activity for infusion into patients with COVID-19. Clinical Trials Registration NCT04434131.


Viruses ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1347
Author(s):  
Claudia Maria Trombetta ◽  
Serena Marchi ◽  
Simonetta Viviani ◽  
Alessandro Manenti ◽  
Linda Benincasa ◽  
...  

The recent spreading of new SARS-CoV-2 variants, carrying several mutations in the spike protein, could impact immune protection elicited by natural infection or conferred by vaccination. In this study, we evaluated the neutralizing activity against the viral variants that emerged in the United Kingdom (B.1.1.7), Brazil (P.1), and South Africa (B.1.351) in human serum samples from hospitalized patients infected by SARS-CoV-2 during the first pandemic wave in Italy in 2020. Of the patients studied, 59.5% showed a decrease (≥2 fold) in neutralizing antibody titer against B.1.1.7, 83.3% against P.1, and 90.5% against B.1.351 with respect to the original strain. The reduction in antibody titers against all analyzed variants, and in particular P.1 and B.1.351, suggests that previous symptomatic infection might be not fully protective against exposure to SARS-CoV-2 variants carrying a set of relevant spike mutations.


2005 ◽  
Vol 12 (1) ◽  
pp. 135-140 ◽  
Author(s):  
Biao Di ◽  
Wei Hao ◽  
Yang Gao ◽  
Ming Wang ◽  
Ya-di Wang ◽  
...  

ABSTRACT Accurate and timely diagnosis of severe acute respiratory syndrome coronavirus (SARS-CoV) infection is a critical step in preventing another global outbreak. In this study, 829 serum specimens were collected from 643 patients initially reported to be infected with SARS-CoV. The sera were tested for the N protein of SARS-CoV by using an antigen capture enzyme-linked immunosorbent assay (ELISA) based on monoclonal antibodies against the N protein of SARS-CoV and compared to 197 control serum samples from healthy donors and non-SARS febrile patients. The results of the N protein detection analysis were directly related to the serological analysis data. From 27 SARS patients who tested positive with the neutralization test, 100% of the 24 sera collected from 1 to 10 days after the onset of symptoms were positive for the N protein. N protein was not detected beyond day 11 in this group. The positive rates of N protein for sera collected at 1 to 5, 6 to 10, 11 to 15, and 16 to 20 days after the onset of symptoms for 414 samples from 298 serologically confirmed patients were 92.9, 69.8, 36.4, and 21.1%, respectively. For 294 sera from 248 serological test-negative patients, the rates were 25.6, 16.7, 9.3, and 0%, respectively. The N protein was not detected in 66 patients with cases of what was initially suspected to be SARS but serologically proven to be negative for SARS and in 197 serum samples from healthy donors and non-SARS febrile patients. The specificity of the assay was 100%. Furthermore, of 16 sera collected from four patients during the SARS recurrence in Guangzhou, 5 sera collected from 7 to 9 days after the onset of symptoms were positive for the N protein. N protein detection exhibited a high positive rate, 96 to 100%, between day 3 and day 5 after the onset of symptoms for 27 neutralization test-positive SARS patients and 298 serologically confirmed patients. The N protein detection rate continually decreased beginning with day 10, and N protein was not detected beyond day 19 after the onset of symptoms. In conclusion, an antigen capture ELISA reveals a high N protein detection rate in acute-phase sera of patients with SARS, which makes it useful for early diagnosis of SARS.


1976 ◽  
Vol 4 (5) ◽  
pp. 437-442
Author(s):  
G Gerna ◽  
R W Chambers

A new plaque assay for the quantitation of varicella-zoster virus and a plaque reduction neutralization test for the determination of neutralizing antibody titer have been developed using the indirect immunoperoxidase technique. As compared with the classical plaque assay using a solid overlay, the test gives earlier results since plaque counting can be performed on day 3 after the inoculation of cell cultures. In six patients with zoster infection, neutralizing antibody titers ranged from 1:20 to 1:40 before the onset of infection and reached high levels (1:320 to 1:5,120) during the convalescent phase of the disease. Complement-fixing (CF) titers were all negative (less than 1:8) in prezoster serum samples from the same patients and ranged from 1:128 to 1:2,048 in the convalescent-phase sera. In the two cases in which late serum samples were available, neutralizing antibody titers matched the preillness levels, whereas CF titers dropped to undetectable levels. Neither neutralizing nor CF antibody was detected in two sera from individuals with no history of varicella-zoster infection. No differences in virus titers or neutralizing antibody titers were observed between the immunoperoxidase and the classical plaque assays. The appropriate characterization of reagent specificity is required before routine application of the test.


2021 ◽  
Vol 156 (Supplement_1) ◽  
pp. S32-S32
Author(s):  
Y R Luo ◽  
C Yun ◽  
A H Wu ◽  
K L Lynch ◽  
I Chakraborty

Abstract Introduction/Objective Since the start of the COVID-19 pandemic, much research has focused on the kinetics and magnitude of humoral immune response. With the advantages of monitoring real-time immunoreactions, label-free immunoassay (LFIA) is becoming a powerful tool in serology studies. We have developed LFIAs to measure SARS- CoV-2 antibody avidity and neutralization activity in a cohort of COVID-19 patients and determine if they correlate with antibody concentration. Serial serum samples collected from mild to severe COVID-19 patients were measured out to 8 months post-symptom onset to determine the durability of the neutralizing antibody response. Methods/Case Report Based on thin-film interferometry technology, we established a label-free IgG avidity assay and a label-free surrogate virus neutralization test (LF-sVNT). For measurement, sensing probes pre-coated with receptor-binding domain (RBD) of SARS-CoV-2 spike protein are applied to serum samples containing SARS-CoV-2 antibodies. The label-free IgG avidity assay measures the binding strength between RBD and IgG under urea dissociation. The LF-sVNT analyzes the binding ability of RBD to ACE2 after neutralizing RBD with antibodies. Results (if a Case Study enter NA) IgG avidity indices and neutralizing antibody titers (IC50) were determined from serum samples (n=246) from COVID-19 patients (n=113). IgG concentrations were measured using a fluorescent immunoassay. The neutralizing antibody titers showed a weak correlation with IgG concentrations and no correlation with IgG avidity indices. Over the time course up to 8 months post-symptom onset, IgG concentrations and neutralizing antibody titers presented similar trends: an initial rise, plateau and then in some cases a gradual decline after 40 days. The IgG avidity indices, in the same cases, plateaued after the initial rise. Conclusion The results demonstrated that LFIA could be used an excellent solution in the determination of SARS- CoV-2 antibody characteristics. The study found that IgG concentration and neutralizing antibody titer declined over time, while IgG avidity index remained constant after reaching a plateau. The decline of antibody neutralization activity can be attributed to the reduction in antibody quantity rather than the deterioration of antibody quality, as measured by antibody avidity.


2021 ◽  
Author(s):  
Nasamon Wanlapakorn ◽  
Nungruthai Suntronwong ◽  
Harit Phowatthanasathian ◽  
Ritthideach Yorsang ◽  
Thanunrat Thongmee ◽  
...  

Abstract Limited data are available on the responses to heterologous vaccine regimens for SARS-CoV-2, especially among countries using inactivated and adenoviral-vectored vaccines. A total of 77 participants who received heterologous prime/booster-inactivated COVID-19 vaccine (CoronaVac) and adenoviral-vectored vaccine (AZD1222) were enrolled in our study. There were two comparison groups vaccinated with the homologous CoronaVac (N = 80) and AZD1222 (N = 80) regimen. All sera samples were tested for SARS-CoV-2 spike receptor-binding-domain (RBD) IgG using a chemiluminescent microparticle immunoassay (CMIA). The neutralizing activity in a subset of serum samples was tested against the original Wuhan strain and variants of concern, B.1.1.7, B.1.617.2 and B.1.351, using an enzyme-linked immunosorbent assay (ELISA)-based surrogate virus neutralization test (sVNT). The heterologous CoronaVac/AZD1222 vaccine induced higher levels of spike RBD-specific IgG than that of two-dose homologous CoronaVac or AZD1222 vaccines (p < 0.001). Sera samples of the CoronaVac/AZD1222 vaccine recipients elicited higher neutralizing antibody activity against the original Wuhan and all variants of concern than in the recipients of the two-dose CoronaVac. Nevertheless, there were no difference in neutralizing activity against the original Wuhan and B.1.1.7 strain among heterologous CoronaVac/AZD1222 and homologous AZD1222 vaccine recipients.


2020 ◽  
Author(s):  
Arantxa Valdivia ◽  
Ignacio Torres ◽  
Victor Latorre ◽  
Carla Frances-Gomez ◽  
Eliseo Albert ◽  
...  

Background: Whether antibody levels measured by commercially-available enzyme or chemiluminescent immunoassays targeting the SARS-CoV-2 spike (S) protein can act as a proxy for serum neutralizing activity remains to be established for many of these assays. Objectives: To evaluate the degree of correlation between neutralizing antibodies (NtAb) binding the SARS-CoV-2 Spike (S) protein and SARS-CoV-2-S-IgG levels measured by four commercial immunoassays in sera drawn from hospitalized COVID-19 patients. Patients and Methods: Ninety sera from 51 hospitalized COVID-19 patients were assayed by a pseudotyped virus neutralization assay, the LIAISON SARS-CoV-2 S1/S2 IgG, the Euroimmun SARS-CoV-2 IgG ELISA, the MAGLUMI 2019-nCoV IgG and the COVID-19 ELISA IgG assays. Results: Overall, the results obtained with the COVID-19 ELISA IgG test showed the highest agreement with the NtAb assay (κ, 0.85; 95% CI, 0.63-1). The most sensitive tests were the pseudotyped virus NtAb assay and the COVID-19 ELISA IgG assay (92.2% for both). Overall, the degree correlation between antibody titers resulting in 50% virus neutralization (NtAb50) in the pseudotyped virus assay and SARS-CoV-2 IgG levels was strong for the Euroimmun SARS-CoV-2 IgG ELISA (Rho=0.73) and moderate for the remaining assays (Rho=0.48 to 0.59). The kinetic profile of serum NtAb50 titers could not be reliably predicted by any of the SARS-CoV-2 IgG immunoassays. Conclusions: the suitability of SARS-CoV-2-S-IgG commercial immunoassays for inferring neutralizing activity of sera from hospitalized COVID-19 patients varies widely across tests and is influenced by the time of sera collection after the onset of symptoms.


2021 ◽  
Author(s):  
Yiqi Ruben Luo ◽  
Cassandra Yun ◽  
Indrani Chakraborty ◽  
Alan H.B. Wu ◽  
Kara L. Lynch

AbstractBackgroundThe laboratory-based methods to measure the SARS-CoV-2 humoral response include virus neutralization tests (VNTs) to determine antibody neutralization potency. For ease of use and universal applicability, surrogate virus neutralization tests (sVNTs) based on antibody-mediated blockage of molecular interactions have been proposed.MethodsA surrogate virus neutralization test established on a label-free immunoassay platform (LF-sVNT). The LF-sVNT analyzes the binding ability of RBD to ACE2 after neutralizing RBD with antibodies in serum.ResultsThe LF-sVNT neutralizing antibody titers (IC50) were determined from serum samples (n=246) from COVID-19 patients (n=113), as well as the IgG concentrations and the IgG avidity indices. Although there is variability in the kinetics of the IgG concentrations and neutralizing antibody titers between individuals, there is an initial rise, plateau and then in some cases a gradual decline at later timepoints after 40 days post-symptom onset. The IgG avidity indices, in the same cases, plateau after the initial rise and did not show a decline.ConclusionsThe LF-sVNT can be a valuable tool in clinical laboratories for the assessment of the presence of neutralizing antibodies to COVID-19. This study is the first to provide longitudinal neutralizing antibody titers beyond 200 days post-symptom onset. Despite the decline of IgG concentration and neutralizing antibody titer, IgG avidity index increases, reaches a plateau and then remains constant up to 8 months post-infection. The decline of antibody neutralization potency can be attributed to the reduction in antibody quantity rather than the deterioration of antibody avidity, a measure of antibody quality.SummaryA surrogate virus neutralization test established on a label-free immunoassay platform (LF-sVNT). Using the LF-sVNT and other assays, 246 serum samples from 113 COVID-19 patients were measured. We observed the time course of antibody characteristics beyond 200 days post-symptom onset.


2011 ◽  
Vol 18 (11) ◽  
pp. 1889-1894 ◽  
Author(s):  
Minetaro Arita ◽  
Masae Iwai ◽  
Takaji Wakita ◽  
Hiroyuki Shimizu

ABSTRACTIn the Global Polio Eradication Initiative, laboratory diagnosis plays a critical role by isolating and identifying poliovirus (PV) from the stool samples from acute flaccid paralysis (AFP) cases. In recent years, reestablishment of PV circulation in countries where PV was previously eliminated has occurred because of decreased herd immunity, possibly due to poor vaccination coverage. To monitor the vulnerability of countries to PV circulation, surveillance of neutralizing-antibody titers against PV in susceptible populations is essential in the end game of the polio eradication program. In this study, we have developed a PV neutralization test with type 1, 2, and 3 PV pseudoviruses to determine the neutralizing-antibody titer against PV in human serum samples. With this test, the neutralizing-antibody titer against PV could be determined within 2 days by automated interpretation of luciferase signals without using infectious PV strains. We validated the pseudovirus PV neutralization test with 131 human serum samples collected from a wide range of age groups (ages 1 to >60 years) by comparison with a conventional neutralization test. We found good correlation in the neutralizing-antibody titers determined by these tests. These results suggest that a pseudovirus PV neutralization test would serve as a safe and simple procedure for the measurement of the neutralizing-antibody titer against PV.


Sign in / Sign up

Export Citation Format

Share Document