scholarly journals X-ray phase-contrast tomography for high-spatial-resolution zebrafish muscle imaging

2015 ◽  
Vol 5 (1) ◽  
Author(s):  
William Vågberg ◽  
Daniel H. Larsson ◽  
Mei Li ◽  
Anders Arner ◽  
Hans M. Hertz
1999 ◽  
Vol 590 ◽  
Author(s):  
F. Beckmann ◽  
U. Bonse

ABSTRACTAttenuation- and phase-contrast microtomography using synchrotron radiation is applied to different samples demonstrating the advantages and limits of the two different contrast mechanism. Photon energies in the range of 8-25 keV and 60-100 keV are used. Scanning techniques employing a 2-dim. x-ray detector allow for investigation of larger specimens at high spatial resolution.


2016 ◽  
Vol 6 (1) ◽  
Author(s):  
I. Bukreeva ◽  
A. Mittone ◽  
A. Bravin ◽  
G. Festa ◽  
M. Alessandrelli ◽  
...  

Abstract A collection of more than 1800 carbonized papyri, discovered in the Roman ‘Villa dei Papiri’ at Herculaneum is the unique classical library survived from antiquity. These papyri were charred during 79 A.D. Vesuvius eruption, a circumstance which providentially preserved them until now. This magnificent collection contains an impressive amount of treatises by Greek philosophers and, especially, Philodemus of Gadara, an Epicurean thinker of 1st century BC. We read many portions of text hidden inside carbonized Herculaneum papyri using enhanced X-ray phase-contrast tomography non-destructive technique and a new set of numerical algorithms for ‘virtual-unrolling’. Our success lies in revealing the largest portion of Greek text ever detected so far inside unopened scrolls, with unprecedented spatial resolution and contrast, all without damaging these precious historical manuscripts. Parts of text have been decoded and the ‘voice’ of the Epicurean philosopher Philodemus is brought back again after 2000 years from Herculaneum papyri.


Radiology ◽  
2021 ◽  
Vol 298 (1) ◽  
pp. 135-146
Author(s):  
Giacomo E. Barbone ◽  
Alberto Bravin ◽  
Alberto Mittone ◽  
Sergio Grosu ◽  
Jens Ricke ◽  
...  

Radiology ◽  
2015 ◽  
Vol 275 (1) ◽  
pp. 310-310 ◽  
Author(s):  
Richard M. Morris ◽  
Lang Yang ◽  
Miguel A. Martín-Fernández ◽  
Jose M. Pozo ◽  
Alejandro F. Frangi ◽  
...  

2021 ◽  
Vol 20 ◽  
pp. 153303382110101
Author(s):  
Thet-Thet Lwin ◽  
Akio Yoneyama ◽  
Hiroko Maruyama ◽  
Tohoru Takeda

Phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer provides high sensitivity and high spatial resolution, and it has the ability to depict the fine morphological structures of biological soft tissues, including tumors. In this study, we quantitatively compared phase-contrast synchrotron-based X-ray computed tomography images and images of histopathological hematoxylin-eosin-stained sections of spontaneously occurring rat testicular tumors that contained different types of cells. The absolute densities measured on the phase-contrast synchrotron-based X-ray computed tomography images correlated well with the densities of the nuclear chromatin in the histological images, thereby demonstrating the ability of phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer to reliably identify the characteristics of cancer cells within solid soft tissue tumors. In addition, 3-dimensional synchrotron-based phase-contrast X-ray computed tomography enables screening for different structures within tumors, such as solid, cystic, and fibrous tissues, and blood clots, from any direction and with a spatial resolution down to 26 μm. Thus, phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer shows potential for being useful in preclinical cancer research by providing the ability to depict the characteristics of tumor cells and by offering 3-dimensional information capabilities.


Nanomaterials ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 1721
Author(s):  
Heon Yong Jeong ◽  
Hyung San Lim ◽  
Ju Hyuk Lee ◽  
Jun Heo ◽  
Hyun Nam Kim ◽  
...  

The effect of scintillator particle size on high-resolution X-ray imaging was studied using zinc tungstate (ZnWO4) particles. The ZnWO4 particles were fabricated through a solid-state reaction between zinc oxide and tungsten oxide at various temperatures, producing particles with average sizes of 176.4 nm, 626.7 nm, and 2.127 μm; the zinc oxide and tungsten oxide were created using anodization. The spatial resolutions of high-resolution X-ray images, obtained from utilizing the fabricated particles, were determined: particles with the average size of 176.4 nm produced the highest spatial resolution. The results demonstrate that high spatial resolution can be obtained from ZnWO4 nanoparticle scintillators that minimize optical diffusion by having a particle size that is smaller than the emission wavelength.


2005 ◽  
Author(s):  
Michael R. Squillante ◽  
Richard A. Myers ◽  
Mitchell Woodring ◽  
James F. Christian ◽  
Frank Robertson ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document