Depth-selective photothermal IR spectroscopy of skin: potential application for non-invasive glucose measurement

The Analyst ◽  
2017 ◽  
Vol 142 (3) ◽  
pp. 495-502 ◽  
Author(s):  
Otto Hertzberg ◽  
Alexander Bauer ◽  
Arne Küderle ◽  
Miguel A. Pleitez ◽  
Werner Mäntele

Photothermal depth profiling is applied to total internal reflection enhanced photothermal deflection spectroscopy (TIR-PTDS) in order to study skin characteristicsin vivoand to improve the sensing technique for non-invasive glucose monitoring.

2017 ◽  
Vol 11 (1) ◽  
pp. e201600261 ◽  
Author(s):  
Alexander Bauer ◽  
Otto Hertzberg ◽  
Arne Küderle ◽  
Dominik Strobel ◽  
Miguel A. Pleitez ◽  
...  

Biosensors ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 189
Author(s):  
David Bamgboje ◽  
Iasonas Christoulakis ◽  
Ioannis Smanis ◽  
Gaurav Chavan ◽  
Rinkal Shah ◽  
...  

Diabetes mellitus (DM) is a chronic disease that must be carefully managed to prevent serious complications such as cardiovascular disease, retinopathy, nephropathy and neuropathy. Self-monitoring of blood glucose is a crucial tool for managing diabetes and, at present, all relevant procedures are invasive while they only provide periodic measurements. The pain and measurement intermittency associated with invasive techniques resulted in the exploration of painless, continuous, and non-invasive techniques of glucose measurement that would facilitate intensive management. The focus of this review paper is the existing solutions for continuous non-invasive glucose monitoring via contact lenses (CLs) and to carry out a detailed, qualitative, and comparative analysis to inform prospective researchers on viable pathways. Direct glucose monitoring via CLs is contingent on the detection of biomarkers present in the lacrimal fluid. In this review, emphasis is given on two types of sensors: a graphene-AgNW hybrid sensor and an amperometric sensor. Both sensors can detect the presence of glucose in the lacrimal fluid by using the enzyme, glucose oxidase. Additionally, this review covers fabrication procedures for CL biosensors. Ever since Google published the first glucose monitoring embedded system on a CL, CL biosensors have been considered state-of-the-art in the medical device research and development industry. The CL not only has to have a sensory system, it must also have an embedded integrated circuit (IC) for readout and wireless communication. Moreover, to retain mobility and ease of use of the CLs used for continuous glucose monitoring, the power supply to the solid-state IC on such CLs must be wireless. Currently, there are four methods of powering CLs: utilizing solar energy, via a biofuel cell, or by inductive or radiofrequency (RF) power. Although, there are many limitations associated with each method, the limitations common to all, are safety restrictions and CL size limitations. Bearing this in mind, RF power has received most of the attention in reported literature, whereas solar power has received the least attention in the literature. CLs seem a very promising target for cutting edge biotechnological applications of diagnostic, prognostic and therapeutic relevance.


Author(s):  
Herbert Fink ◽  
Tim Maihöfer ◽  
Jeffrey Bender ◽  
Jochen Schulat

Abstract Blood glucose monitoring (BGM) is the most important part of diabetes management. In classical BGM, glucose measurement by test strips involves invasive finger pricking. We present results of a clinical study that focused on a non-invasive approach based on volatile organic compounds (VOCs) in exhaled breath. Main objective was the discovery of markers for prediction of blood glucose levels (BGL) in diabetic patients. Exhaled breath was measured repeatedly in 60 diabetic patients (30 type 1, 30 type 2) in fasting state and after a standardized meal. Proton Transfer Reaction Time of Flight Mass Spectrometry (PTR-ToF-MS) was used to sample breath every 15 minutes for a total of six hours. BGLs were tested in parallel via BGM test strips. VOC signals were plotted against glucose trends for each subject to identify correlations. Exhaled indole (a bacterial metabolite of tryptophan) showed significant mean correlation to BGL (with negative trend) and significant individual correlation in 36 patients. The type of diabetes did not affect this result. Additional experiments of one healthy male subject by ingestion of lactulose and 13C-labeled glucose (n=3) revealed that exhaled indole does not directly originate from food digestion by intestinal microbiota. As indole has been linked to human glucose metabolism, it might be a tentative marker in breath for non-invasive BGM. Clinical studies with greater diversity are required for confirmation of such results and further investigation of metabolic pathways.


2007 ◽  
Vol 353 (47-51) ◽  
pp. 4515-4517 ◽  
Author(s):  
Mark S. Talary ◽  
François Dewarrat ◽  
Daniel Huber ◽  
Andreas Caduff

2019 ◽  
Vol 8 (4) ◽  
pp. 6437-6441

Diabetes has shown to be a chronic disease world over, mainly caused due to reduced physical activity and increased obesity. World health organization statistics show diabetes as a leading cause of disability universally. To avoid extreme medical conditions of subjects, regular monitoring of their glucose levels has been suggested. The most common method that has been in use is the pinprick method for glucose monitoring which carries the risk of contamination as well as irritation. One possible approach called noninvasive technique can be adopted to avoid this major concern. This paper presents designing Inter-Digital-Sensor (IDS) for non-invasive sensing of the glucose level. The sensor-based chip once mounted onto the upper arm or pinkie finger of diabetes subject, is able to sense different glucose levels concentration as impedance plots. A set of several simulation results has been obtained using COMSOL for getting optimized dimensions of the sensor digits. This research has presented the generation of an electric field and intensity by using electrode of known length with element spacing varying from 250µm to 600µm developed over 15mm x 20mm sensor area. An ID of 475µm width spacing with ten (10) digits producing 2.33 pF of capacitance value with impedance resonating at 13 GHz of frequency is reported in this paper


2021 ◽  
Vol 2008 (1) ◽  
pp. 012003
Author(s):  
B G Pedro ◽  
P Bertemes-Filho

Abstract Continuous glucose monitoring is essential to reduce the damages caused by diabetes and for choosing the right treatment approach. In most cases, non-invasive glucose measurement devices generate their results through statistical tools (e.g., artificial neural networks) with an error that increases the further away from the training sample the measurement is. An analytical model would contain only propagated errors. Impedance measurements of lactate ringer’s solutions with egg albumin containing different concentrations of sugar were performed to validate the model proposed for measuring glycemia in human blood using the electrical bioimpedance meter AD5933. The curve fitting showed errors lower than 1.5%. Chemical phenomena, such as reduced sugar, fructosamine and solvation, might explain the behaviors observed in the experiments. The results suggest that the relaxation coefficient has significant changes with the increase of sugar in the solutions. The findings encourage future research with bovine blood for a more realistic analytical model.


Sign in / Sign up

Export Citation Format

Share Document