scholarly journals Raman spectroscopy as a potential tool for label free therapeutic drug monitoring in human serum: the case of busulfan and methotrexate

The Analyst ◽  
2019 ◽  
Vol 144 (17) ◽  
pp. 5207-5214 ◽  
Author(s):  
Drishya Rajan Parachalil ◽  
Deirdre Commerford ◽  
Franck Bonnier ◽  
Igor Chourpa ◽  
Jennifer McIntyre ◽  
...  

A methodology is proposed, based on Raman spectroscopy coupled with multivariate analysis, to determine the Limit of Detection (LOD) and Limit of Quantification (LOQ) for therapeutic drug monitoring in human serum, using the examples of Busulfan and Methotrexate.

2021 ◽  
Vol 15 (Supplement_1) ◽  
pp. S396-S397
Author(s):  
A Ametzazurra ◽  
J Pascual ◽  
L Del Rio ◽  
A Maguregui ◽  
D Nagore ◽  
...  

Abstract Background Promonitor Quick IFX is a lateral flow test (LFT) for the quantification of infliximab (IFX) in human whole blood (finger prick or venous) or serum in 20 minutes. This LFT is based on a sandwich immunoassay to quantify either the reference IFX or biosimilars. This abstract describes the studies performed to establish the analytical specifications of the product. Methods Clinical and Laboratory Standards Institute (CLSI) guidelines were followed for the evaluation of the analytical specifications of the LFT in whole blood and serum matrices: Linearity (EP-06-A), Detection capability (EP17-A2), Interfering substances (EP07, 3rd Edition), Intermediate precision (EP05-A3) and Bias evaluation study for Biosimilars (EP10-A3). Results were obtained in combination with the automated portable reader PQreader. A Datamatrix provided with each Promonitor Quick IFX kit contains the calibration information required for the PQreader to measure the Control and Test lines and report the IFX concentration. Results The linear assay range was determined to be 1-58 µg/mL in whole-blood and 0.6-67 µg/mL in serum according to the processes indicated in the Package Insert. The Limit of Blank is 0.8 μg/mL, the Limit of Detection and Lower Limit of Quantification (LLoQ) are 1.1 μg/mL, and the Upper Limit of Quantification (ULoQ) is 15.4 μg/mL. There was no effect on assay performance when each of the following substances were added to samples with 0, 3, and 7 μg/mL of IFX: Haemoglobin (>1000 mg/dL), Bilirubin (>40 mg/dL), Triglycerides (>1500 mg/dL), HAMA (160 AU/mL), Rheumatoid factor (200 IU/mL), EDTA (5.4 mg/mL), Heparin (51 U/mL), Citrate (11.4%), Vedolizumab (60 μg/mL) and Adalimumab (20.25 μg/mL). Repeatability and within-device precision results obtained for the positive samples are shown in the table below. The negative samples showed a negative result in all the measurements. A bias study showed that Promonitor Quick IFX can quantify CT-P13, SB2 and GP1111 biosimilars throughout the measurement range with a maximum bias of 14%. Conclusion Promonitor Quick IFX is the first LFT available for true Point of Care testing of patients treated with IFX with just a finger prick sample. It provides quick turnaround time to facilitate therapeutic drug monitoring and aid immediate decision making in the doctor office or hospitals with an excellent analytical performance.


mSphere ◽  
2018 ◽  
Vol 3 (6) ◽  
Author(s):  
Gregory R. Wiedman ◽  
Yanan Zhao ◽  
David S. Perlin

ABSTRACT Clinicians need a better way to accurately monitor the concentration of antimicrobials in patient samples. In this report, we describe a novel, low-sample-volume method to monitor the azole-class antifungal drug posaconazole, as well as certain other long-chain azole-class antifungal drugs in human serum samples. Posaconazole represents an important target for therapeutic drug monitoring (TDM) due to its widespread use in treating invasive fungal infections and well-recognized variability of pharmacokinetics. The current “gold standard” requires trough and peak monitoring through high-pressure liquid chromatography (HPLC) or liquid chromatography-tandem mass spectroscopy (LC-MS/MS). Other methods include bioassays that use highly susceptible strains of fungi in culture plates or 96-well formats to monitor concentrations. Currently, no method exists that is both highly accurate in detecting free drug concentrations and is also rapid. Herein, we describe a new method using reduced graphene oxide (rGO) and a fluorescently labeled aptamer, which can accurately assess clinically relevant concentrations of posaconazole and other long-chain azole-class drugs in little more than 1 h in a total volume of 100 µl. IMPORTANCE This work describes an effective assay for TDM of long-chain azole-class antifungal drugs that can be used in diluted human serum samples. This assay will provide a quick, cost-effective method for monitoring concentrations of drugs such as posaconazole that exhibit well-documented pharmacokinetic variability. Our rGO-aptamer assay has the potential to improve health care for those struggling to treat fungal infections in rural or resource-limited setting.


2022 ◽  
pp. ejhpharm-2021-003036
Author(s):  
Stefan Günther ◽  
Andreas Reimer ◽  
Horst Vogl ◽  
Stephan Spenke ◽  
Hanns-Christian Dinges ◽  
...  

Talanta ◽  
2020 ◽  
Vol 218 ◽  
pp. 121138 ◽  
Author(s):  
Sandeep Surendra Panikar ◽  
Nehla Banu ◽  
Elia-Reza Escobar ◽  
Gonzalo-Ramírez García ◽  
Jesús Cervantes-Martínez ◽  
...  

1996 ◽  
Vol 42 (12) ◽  
pp. 1943-1948 ◽  
Author(s):  
K L Napoli ◽  
B D Kahan

Abstract During phase I/II clinical trials of sirolimus (rapamycin; SRL), therapeutic drug monitoring was performed with a multistep liquid-liquid extraction of 1-mL aliquots of whole blood followed by reversed-phase HPLC with ultraviolet detection. Blood was sampled according to a standardized protocol and clinical status. SRL concentrations were interpolated from calibration curves with a linear range of 0-50 micrograms/L and 1 microgram/L lower limit of quantification. Quality control was monitored over 68 consecutive analytical runs by using frozen aliquots of SRL-supplemented pooled whole blood at 4, 12, and 32 micrograms/L. These samples showed mean concentrations of 3.7 +/- 0.6, 10.9 +/- 1.1, and 29.6 +/- 2.6 micrograms/L, respectively. This method for therapeutic drug monitoring of SRL permits one full-time technician to analyze 100 clinical specimens per week with a 24-h turnaround time. With this method, a strong linear relation (r2 = 0.946, Sy/x = 0.41, n = 115) between the average SRL concentration over a 24-h period and the SRL concentration at the 24th h was revealed.


2018 ◽  
Vol 91 (3) ◽  
pp. 2100-2111 ◽  
Author(s):  
Sandeep Surendra Panikar ◽  
Gonzalo Ramírez-García ◽  
Siraj Sidhik ◽  
Tazara Lopez-Luke ◽  
Claramaria Rodriguez-Gonzalez ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document