Total reflection X-ray fluorescence analysis of aerosol particles with direct dissolution of the collection filter on a substrate

Author(s):  
Tsugufumi Matsuyama ◽  
Hiroki Yamaguchi ◽  
Kouichi Tsuji

In this study, a novel method based on total reflection X-ray analysis was developed for determining the trace elements in aerosol particles.

2013 ◽  
Vol 93 (10) ◽  
pp. 1043-1051 ◽  
Author(s):  
Ralitsa Georgieva ◽  
Albena Detcheva ◽  
Methody Karadjov ◽  
Juri Jordanov ◽  
Elisaveta Ivanova

1993 ◽  
Vol 39 (6) ◽  
pp. 1037-1041 ◽  
Author(s):  
P Dogan ◽  
M Dogan ◽  
R Klockenkämper

Abstract The distribution of trace elements Fe, Cu, Zn, Se, and Rb was determined in sera from patients with the complete type of Behçet disease in the active stage and from healthy controls. Total reflection x-ray fluorescence was used for quantitative analysis; in general, atomic absorption spectrometry was used only for control of the Se values. Zn, Se, and Rb concentrations were significantly (P < 0.0001) lower for patients than for control subjects. No significant difference was determined in the Fe content. However, there was a significant increase in Cu in the patients so that the ratios Cu/Zn, Cu/Se, and Cu/Rb were significantly higher for the patients than for the control subjects (P < 0.0001).


2010 ◽  
Vol 65 (6) ◽  
pp. 499-503 ◽  
Author(s):  
T. Martinez ◽  
J. Lartigue ◽  
G. Zarazua ◽  
P. Avila-Perez ◽  
M. Navarrete ◽  
...  

Author(s):  
D. A. Carpenter ◽  
Ning Gao ◽  
G. J. Havrilla

A monolithic, polycapillary, x-ray optic was adapted to a laboratory-based x-ray microprobe to evaluate the potential of the optic for x-ray micro fluorescence analysis. The polycapillary was capable of collecting x-rays over a 6 degree angle from a point source and focusing them to a spot approximately 40 µm diameter. The high intensities expected from this capillary should be useful for determining and mapping minor to trace elements in materials. Fig. 1 shows a sketch of the capillary with important dimensions.The microprobe had previously been used with straight and with tapered monocapillaries. Alignment of the monocapillaries with the focal spot was accomplished by electromagnetically scanning the focal spot over the beveled anode. With the polycapillary it was also necessary to manually adjust the distance between the focal spot and the polycapillary.The focal distance and focal spot diameter of the polycapillary were determined from a series of edge scans.