Dynamic screening and printing of single cells using a microfluidic chip with dual microvalves

Lab on a Chip ◽  
2020 ◽  
Vol 20 (7) ◽  
pp. 1227-1237 ◽  
Author(s):  
Chang Chen ◽  
Dong Xu ◽  
Siwei Bai ◽  
Zhihang Yu ◽  
Yonggang Zhu ◽  
...  

Inoculation of single cells into separate chambers is one of the key requirements in single-cell analysis. Here we report a three-layer microfluidic platform integrated with dual-pneumatic valves for dynamic screening and printing of single cells.

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Jeremy A. Lombardo ◽  
Marzieh Aliaghaei ◽  
Quy H. Nguyen ◽  
Kai Kessenbrock ◽  
Jered B. Haun

AbstractTissues are complex mixtures of different cell subtypes, and this diversity is increasingly characterized using high-throughput single cell analysis methods. However, these efforts are hindered, as tissues must first be dissociated into single cell suspensions using methods that are often inefficient, labor-intensive, highly variable, and potentially biased towards certain cell subtypes. Here, we present a microfluidic platform consisting of three tissue processing technologies that combine tissue digestion, disaggregation, and filtration. The platform is evaluated using a diverse array of tissues. For kidney and mammary tumor, microfluidic processing produces 2.5-fold more single cells. Single cell RNA sequencing further reveals that endothelial cells, fibroblasts, and basal epithelium are enriched without affecting stress response. For liver and heart, processing time is dramatically reduced. We also demonstrate that recovery of cells from the system at periodic intervals during processing increases hepatocyte and cardiomyocyte numbers, as well as increases reproducibility from batch-to-batch for all tissues.


2020 ◽  
Author(s):  
Jeremy Lombardo ◽  
Marzieh Aliaghaei ◽  
Quy Nguyen ◽  
Kai Kessenbrock ◽  
Jered Haun

Abstract Tissues are composed of highly heterogeneous mixtures of cell subtypes, and this diversity is increasingly being characterized using high-throughput single cell analysis methods. However, these efforts are hindered by the fact that tissues must first be dissociated into single cell suspensions that are viable and still accurately represent phenotypes from the original tissue. Current methods for breaking down tissues are inefficient, labor-intensive, subject to high variability, and potentially biased towards cell subtypes that are easier to release. Here, we present a microfluidic platform consisting of three different tissue processing technologies that can perform the complete tissue to single cell workflow, including digestion, disaggregation, and filtration. First, we developed a new microfluidic digestion device that can be loaded with minced tissue specimens quickly and easily, and then use the combination of proteolytic enzyme activity and fluid shear forces to accelerate tissue breakdown. Next, we integrated dissociation and filter technologies into a single device, which enhanced single cell numbers and fully prepared the sample for single cell analysis. The final multi-device platform was then evaluated using a diverse array of tissue types that exhibited a wide range of properties. For murine kidney and mammary tumor, we found that microfluidic processing produced 2.5-fold more single, viable cells. Single cell RNA sequencing (scRNA-seq) further revealed that device processing enriched for endothelial cells, fibroblasts, and basal epithelium, and did not increase stress responses. For murine liver and heart, which are softer tissues containing fragile cell types, processing time could be reduced to 15 min, and even as short as 1 min. We also demonstrated that periodic recovery at defined time intervals produced substantially more hepatocytes and cardiomyocytes than continuous operation, most likely by preventing damage to fragile cell types. In future work, we will seek to integrate additional operations such as upstream tissue preparation and downstream microfluidic cell sorting and detection to create powerful point-of-care single cell diagnostic platforms.


Micromachines ◽  
2019 ◽  
Vol 10 (6) ◽  
pp. 409 ◽  
Author(s):  
Bing Deng ◽  
Heyi Wang ◽  
Zhaoyi Tan ◽  
Yi Quan

The single-cell capture microfluidic chip has many advantages, including low cost, high throughput, easy manufacturing, integration, non-toxicity and good stability. Because of these characteristics, the cell capture microfluidic chip is increasingly becoming an important carrier on the study of life science and pharmaceutical analysis. Important promises of single-cell analysis are the paring, fusion, disruption and analysis of intracellular components for capturing a single cell. The capture, which is based on the fluid dynamics method in the field of micro fluidic chips is an important way to achieve and realize the operations mentioned above. The aim of this study was to compare the ability of three fluid dynamics-based microfluidic chip structures to capture cells. The effects of cell growth and distribution after being captured by different structural chips and the subsequent observation and analysis of single cells on the chip were compared. It can be seen from the experimental results that the microfluidic chip structure most suitable for single-cell capture is a U-shaped structure. It enables single-cell capture as well as long-term continuous culture and the single-cell observation of captured cells. Compared to the U-shaped structure, the cells captured by the microcavity structure easily overlapped during the culture process and affected the subsequent analysis of single cells. The flow shortcut structure can also be used to capture and observe single cells, however, the shearing force of the fluid caused by the chip structure is likely to cause deformation of the cultured cells. By comparing the cell capture efficiency of the three chips, the reagent loss during the culture process and the cell growth state of the captured cells, we are provided with a theoretical support for the design of a single-cell capture microfluidic chip and a reference for the study of single-cell capture in the future.


2019 ◽  
Author(s):  
Wu Liu ◽  
Mehmet U. Caglar ◽  
Zhangming Mao ◽  
Andrew Woodman ◽  
Jamie J. Arnold ◽  
...  

SUMMARYDevelopment of antiviral therapeutics emphasizes minimization of the effective dose and maximization of the toxic dose, first in cell culture and later in animal models. Long-term success of an antiviral therapeutic is determined not only by its efficacy but also by the duration of time required for drug-resistance to evolve. We have developed a microfluidic device comprised of ~6000 wells, with each well containing a microstructure to capture single cells. We have used this device to characterize enterovirus inhibitors with distinct mechanisms of action. In contrast to population methods, single-cell analysis reveals that each class of inhibitor interferes with the viral infection cycle in a manner that can be distinguished by principal component analysis. Single-cell analysis of antiviral candidates reveals not only efficacy but also properties of the members of the viral population most sensitive to the drug, the stage of the lifecycle most affected by the drug, and perhaps even if the drug targets an interaction of the virus with its host.


2020 ◽  
Author(s):  
Tyler N. Chen ◽  
Anushka Gupta ◽  
Mansi Zalavadia ◽  
Aaron M. Streets

AbstractSingle-cell RNA sequencing (scRNA-seq) enables the investigation of complex biological processes in multicellular organisms with high resolution. However, many phenotypic features that are critical to understanding the functional role of cells in a heterogeneous tissue or organ are not directly encoded in the genome and therefore cannot be profiled with scRNA-seq. Quantitative optical microscopy has long been a powerful approach for characterizing diverse cellular phenotypes including cell morphology, protein localization, and chemical composition. Combining scRNA-seq with optical imaging has the potential to provide comprehensive single-cell analysis, allowing for functional integration of gene expression profiling and cell-state characterization. However, it is difficult to track single cells through both measurements; therefore, coupling current scRNA-seq protocols with optical measurements remains a challenge. Here, we report Microfluidic Cell Barcoding and Sequencing (μCB-seq), a microfluidic platform that combines high-resolution imaging and sequencing of single cells. μCB-seq is enabled by a novel fabrication method that preloads primers with known barcode sequences inside addressable reaction chambers of a microfluidic device. In addition to enabling multi-modal single-cell analysis, μCB-seq improves gene detection sensitivity, providing a scalable and accurate method for information-rich characterization of single cells.


2020 ◽  
Vol 52 (10) ◽  
pp. 468-477
Author(s):  
Alexander C. Zambon ◽  
Tom Hsu ◽  
Seunghee Erin Kim ◽  
Miranda Klinck ◽  
Jennifer Stowe ◽  
...  

Much of our understanding of the regulatory mechanisms governing the cell cycle in mammals has relied heavily on methods that measure the aggregate state of a population of cells. While instrumental in shaping our current understanding of cell proliferation, these approaches mask the genetic signatures of rare subpopulations such as quiescent (G0) and very slowly dividing (SD) cells. Results described in this study and those of others using single-cell analysis reveal that even in clonally derived immortalized cancer cells, ∼1–5% of cells can exhibit G0 and SD phenotypes. Therefore to enable the study of these rare cell phenotypes we established an integrated molecular, computational, and imaging approach to track, isolate, and genetically perturb single cells as they proliferate. A genetically encoded cell-cycle reporter (K67p-FUCCI) was used to track single cells as they traversed the cell cycle. A set of R-scripts were written to quantify K67p-FUCCI over time. To enable the further study G0 and SD phenotypes, we retrofitted a live cell imaging system with a micromanipulator to enable single-cell targeting for functional validation studies. Single-cell analysis revealed HT1080 and MCF7 cells had a doubling time of ∼24 and ∼48 h, respectively, with high duration variability in G1 and G2 phases. Direct single-cell microinjection of mRNA encoding (GFP) achieves detectable GFP fluorescence within ∼5 h in both cell types. These findings coupled with the possibility of targeting several hundreds of single cells improves throughput and sensitivity over conventional methods to study rare cell subpopulations.


The Analyst ◽  
2019 ◽  
Vol 144 (10) ◽  
pp. 3226-3238 ◽  
Author(s):  
Jitraporn Vongsvivut ◽  
David Pérez-Guaita ◽  
Bayden R. Wood ◽  
Philip Heraud ◽  
Karina Khambatta ◽  
...  

Coupling synchrotron IR beam to an ATR element enhances spatial resolution suited for high-resolution single cell analysis in biology, medicine and environmental science.


2011 ◽  
Vol 32 (22) ◽  
pp. 3094-3100 ◽  
Author(s):  
Floris T. G. van den Brink ◽  
Elmar Gool ◽  
Jean-Philippe Frimat ◽  
Johan Bomer ◽  
Albert van den Berg ◽  
...  

2017 ◽  
Vol 49 (9) ◽  
pp. 491-495
Author(s):  
Hilary A. Coller

Emerging technologies for the analysis of genome-wide information in single cells have the potential to transform many fields of biology, including our understanding of cell states, the response of cells to external stimuli, mosaicism, and intratumor heterogeneity. At Experimental Biology 2017 in Chicago, Physiological Genomics hosted a symposium in which five leaders in the field of single cell genomics presented their recent research. The speakers discussed emerging methodologies in single cell analysis and critical issues for the analysis of single cell data. Also discussed were applications of single cell genomics to understanding the different types of cells within an organism or tissue and the basis for cell-to-cell variability in response to stimuli.


Sign in / Sign up

Export Citation Format

Share Document