scholarly journals High-sensitivity, fast-response flexible pressure sensor for electronic skin using direct writing printing

RSC Advances ◽  
2020 ◽  
Vol 10 (44) ◽  
pp. 26188-26196 ◽  
Author(s):  
Xiaojun Chen ◽  
Xitong Lin ◽  
Deyun Mo ◽  
Xiaoqun Xia ◽  
Manfeng Gong ◽  
...  

Bionic electronic skin with human sensory capabilities has attracted extensive research interest, which has been applied in the fields of medical health diagnosis, wearable electronics, human–computer interaction, and bionic prosthetics.

Nanomaterials ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 716
Author(s):  
Xiao-Quan Shen ◽  
Ming-Ding Li ◽  
Jun-Peng Ma ◽  
Qun-Dong Shen

Multi-functional electronic skin is of paramount significance for wearable electronics in health monitoring, medical analysis, and human-machine interfacing systems. In order to achieve the function of natural skin, mechanical sensing with high sensitivity is an important feature of electronic skin. Inspired by the spinosum structure under the skin, herein, we fabricate a new capacitive pressure sensor with two-dimensional transition-metal carbides and nitrides (MXene) and ferroelectric polymer (P(VDF-TrFE-CFE)) as an active layer and micropatterned Cr-Au deposited on polydimethylsiloxane as flexible electrodes. Such a method is facile, effective, easily operated, and low-cost. The device design provides great capacitive change as a consequence of large deformation under pressure. Benefiting from the randomly distributed microstructure and high dielectric constant of the active layer, the device demonstrates high sensitivity with great linearity (16.0 kPa−1 for less than 10 kPa), that is, a low detection limit of 8.9 Pa, and quick response. A series of dynamic physiological signals, including typing, knuckle motion, and voice recognition can be facilely detected, making it a competitive candidate in the field of wearable electronics.


2020 ◽  
Vol 12 (1) ◽  
Author(s):  
Jung Joon Lee ◽  
Srinivas Gandla ◽  
Byeongjae Lim ◽  
Sunju Kang ◽  
Sunyoung Kim ◽  
...  

Abstract Conformal and ultrathin coating of highly conductive PEDOT:PSS on hydrophobic uneven surfaces is essential for resistive-based pressure sensor applications. For this purpose, a water-based poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) solution was successfully exchanged to an organic solvent-based PEDOT:PSS solution without any aggregation or reduction in conductivity using the ultrafiltration method. Among various solvents, the ethanol (EtOH) solvent-exchanged PEDOT:PSS solution exhibited a contact angle of 34.67°, which is much lower than the value of 96.94° for the water-based PEDOT:PSS solution. The optimized EtOH-based PEDOT:PSS solution exhibited conformal and uniform coating, with ultrathin nanocoated films obtained on a hydrophobic pyramid polydimethylsiloxane (PDMS) surface. The fabricated pressure sensor showed high performances, such as high sensitivity (−21 kPa−1 in the low pressure regime up to 100 Pa), mechanical stability (over 10,000 cycles without any failure or cracks) and a fast response time (90 ms). Finally, the proposed pressure sensor was successfully demonstrated as a human blood pulse rate sensor and a spatial pressure sensor array for practical applications. The solvent exchange process using ultrafiltration for these applications can be utilized as a universal technique for improving the coating property (wettability) of conducting polymers as well as various other materials.


Author(s):  
Jiang Zhao ◽  
Jiahao Gui ◽  
Jinsong Luo ◽  
Jing Gao ◽  
Caidong Zheng ◽  
...  

Abstract Graphene-based pressure sensors have received extensive attention in wearable devices. However, reliable, low-cost, and large-scale preparation of structurally stable graphene electrodes for flexible pressure sensors is still a challenge. Herein, for the first time, laser-induced graphene (LIG) powder are prepared into screen printing ink, and shape-controllable LIG patterned electrodes can be obtained on various substrates using a facile screen printing process, and a novel asymmetric pressure sensor composed of the resulting screen-printed LIG electrodes has been developed. Benefit from the 3D porous structure of LIG, the as-prepared flexible LIG screen-printed asymmetric pressure sensor has super sensing properties with a high sensitivity of 1.86 kPa−1, low detection limit of about 3.4 Pa, short response time, and long cycle durability. Such excellent sensing performances give our flexible asymmetric LIG screen-printed pressure sensor the ability to realize real-time detection of tiny body physiological movements (such as wrist pulse and pronunciation action). Besides, the integrated sensor array has a multi-touch function. This work could stimulate an appropriate approach to designing shape-controllable LIG screen-printed patterned electrodes on various flexible substrates to adapt the specific needs of fulfilling compatibility and modular integration for potential application prospects in wearable electronics.


2019 ◽  
Vol 294 ◽  
pp. 45-53 ◽  
Author(s):  
Shengnan Chang ◽  
Jin Li ◽  
Yin He ◽  
Hao Liu ◽  
Bowen Cheng

Nanomaterials ◽  
2020 ◽  
Vol 10 (4) ◽  
pp. 664 ◽  
Author(s):  
Junsong Hu ◽  
Junsheng Yu ◽  
Ying Li ◽  
Xiaoqing Liao ◽  
Xingwu Yan ◽  
...  

The reasonable design pattern of flexible pressure sensors with excellent performance and prominent features including high sensitivity and a relatively wide workable linear range has attracted significant attention owing to their potential application in the advanced wearable electronics and artificial intelligence fields. Herein, nano carbon black from kerosene soot, an atmospheric pollutant generated during the insufficient burning of hydrocarbon fuels, was utilized as the conductive material with a bottom interdigitated textile electrode screen printed using silver paste to construct a piezoresistive pressure sensor with prominent performance. Owing to the distinct loose porous structure, the lumpy surface roughness of the fabric electrodes, and the softness of polydimethylsiloxane, the piezoresistive pressure sensor exhibited superior detection performance, including high sensitivity (31.63 kPa−1 within the range of 0–2 kPa), a relatively large feasible range (0–15 kPa), a low detection limit (2.26 pa), and a rapid response time (15 ms). Thus, these sensors act as outstanding candidates for detecting the human physiological signal and large-scale limb movement, showing their broad range of application prospects in the advanced wearable electronics field.


Sign in / Sign up

Export Citation Format

Share Document