scholarly journals Integrated all-solid-state sulfite sensors modified with two different ion-to-electron transducers: rapid assessment of sulfite in beverages

RSC Advances ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 3783-3791
Author(s):  
Hisham S. M. Abd-Rabboh ◽  
Abd El-Galil E. Amr ◽  
Ayman H. Kamel ◽  
Mohamed A. Al-Omar ◽  
Ahmed Y. A. Sayed

An integrated all-solid-state screen-printed ion-selective potentiometric sensor for rapid assessment of sulfite ion in beverages, based on analytical transduction, is described.

2021 ◽  
Author(s):  
Manar Omar Heragy ◽  
Azza Mustafa ◽  
Eman Elzanfaly ◽  
Ahmed Sayed Saad

Food additives are chemicals added to enhance appearance, taste, or lifetime of food products. Authorities continuously update lists of the allowed additives and their daily intake limits. Thus, authorities and...


1996 ◽  
Vol 33 (1-3) ◽  
pp. 168-172 ◽  
Author(s):  
R.W. Hower ◽  
J.H. Shin ◽  
G.S. Cha ◽  
R.K. Meruva ◽  
M.E. Meyerhoff ◽  
...  

1994 ◽  
pp. 142
Author(s):  
Bemhard P.H Schaffar ◽  
Andreas M. Dolezal ◽  
Wolfgang P. Kienberger ◽  
Helmut Offenbacher ◽  
Josef Riegebauer ◽  
...  

2020 ◽  
Vol 44 (35) ◽  
pp. 15260-15269
Author(s):  
Khadiga M. Kelani ◽  
Eman S. Elzanfaly ◽  
Michael K. Halim ◽  
Ahmed S. Saad

The DOE optimization of a solid-state potentiometric sensor for isoxsuprine assay in the presence of its photothermal degradation products within complex matrices.


Materials ◽  
2019 ◽  
Vol 12 (18) ◽  
pp. 2924 ◽  
Author(s):  
Samar Ezzat ◽  
Mona A. Ahmed ◽  
Abd El-Galil E. Amr ◽  
Mohamed A. Al-Omar ◽  
Ayman H. Kamel ◽  
...  

A novel single-piece all-solid-state ion-selective electrode (SC/ISE) based on carbon-screen printed is introduced. Polyaniline (PANI) is dissolved in a membrane cocktail that contains the same components used for making a conventional ion-selective polyvinyl chloride (PVC) matrix membrane. The membrane, having the PANI, is directly drop-casted on a carbon substrate (screen-printed-carbon electrode). PANI was added to act as an intermediary between the substrate and the membrane for the charge transfer process. Under non-equilibrium sensing mechanism, the sensors revealed high sensitivity towards 2,4-dichlorophenol (DCP) over the linearity range 0.47 to 13 µM and a detection limit 0.13 µm. The selectivity was measured by the modified separate solution method (MSSM) and showed good selectivity towards 2,4-DCP over the most commonly studied ions. All measurements were done in 30 mm Tris buffer solution at a pH 5.0. Using constant-current chronopotentiometry, the potential drift for the proposed electrodes was checked. Improvement in the potential stability of the SPE was observed after the addition of PANI in the sensing membrane as compared to the corresponding coated-wire electrode (membrane without PANI). The applicability of the sensor has been checked by measuring 2,4-DCP in different water samples and the results were compared with the standard HPLC method.


Sign in / Sign up

Export Citation Format

Share Document