Highly stretchable and anti-freezing silk-based conductive hydrogel for applications as a self-adhesive and transparent ionotronic skin

Author(s):  
Bohua Zhao ◽  
Qianying Chen ◽  
Gaohuan Da ◽  
Zhengzhong Shao ◽  
Jinrong Yao ◽  
...  

Soft electronic devices have rapidly developed and gained increasing attention in the past few years. Herein, a conductive silk-based hydrogel is prepared by crosslinking regenerated silk fibroin (RSF) aqueous solution...

1968 ◽  
Vol 24 (9) ◽  
pp. 449-450 ◽  
Author(s):  
Kiyoshi Hirabayashi ◽  
Hiroshi Ishikawa

2013 ◽  
Vol 28 (20) ◽  
pp. 2897-2902 ◽  
Author(s):  
Yuan Jin ◽  
Yaopeng Zhang ◽  
Yichun Hang ◽  
Huili Shao ◽  
Xuechao Hu

Abstract


2006 ◽  
Vol 20 (25n27) ◽  
pp. 3878-3883 ◽  
Author(s):  
FANG XIE ◽  
HUILI SHAO ◽  
XUECHAO HU

Concentrated regenerated silk fibroin (RSF) aqueous solutions with concentration close to that of the native silk fibroin (15.5%, 25.5% and 31%) were prepared. The effect of storage time and concentration on the conformational transition of the concentrated RSF aqueous solution was studied by Raman spectroscopy and circular dichroism (CD) spectroscopy. At the same time, the conformational change of RSF aqueous solution in flowing state was also investigated. It was found that the conformation of silk fibroin was changed gradually from random coil/α-helix to β-sheet structure during the storage. And the conformational transformation was accelerated with the increasing of the RSF aqueous solution concentration. When the solution was in flowing state, the conformational transformation was also accelerated.


2013 ◽  
Vol 788 ◽  
pp. 174-177 ◽  
Author(s):  
Hao Liu ◽  
Ju Wei ◽  
Lai Jiu Zheng ◽  
Yu Ping Zhao

Waste silk fibers were dissolved in calcium chloride aqueous solution. Effect of calcium chloride concentration on silk solubility was studied. Dialysis method was used to purify the dissolved silk fibroin. The purified silk fibroin was characterized by FTIR and thermoanalysis technique. Results showed that the purified silk fibroin mainly had irregular curly conformation. The glass transition temperature of the regenerated silk fibroin reached 90.6°C-135°C, higher than 78.9°C-135°C before purification. Thermal weight loss temperature by 50% was 490.3°C differing from 429.7°C before purification.


2011 ◽  
Vol 31 (7) ◽  
pp. 1602-1608 ◽  
Author(s):  
Wei Wei ◽  
Yaopeng Zhang ◽  
Yingmei Zhao ◽  
Jie Luo ◽  
Huili Shao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document