chloride concentration
Recently Published Documents


TOTAL DOCUMENTS

1474
(FIVE YEARS 309)

H-INDEX

63
(FIVE YEARS 7)

2022 ◽  
Vol 6 (1) ◽  
Author(s):  
Qing Li ◽  
Xiaojian Xia ◽  
Zibo Pei ◽  
Xuequn Cheng ◽  
Dawei Zhang ◽  
...  

AbstractIn this work, the atmospheric corrosion of carbon steels was monitored at six different sites (and hence, atmospheric conditions) using Fe/Cu-type atmospheric corrosion monitoring technology over a period of 12 months. After analyzing over 3 million data points, the sensor data were interpretable as the instantaneous corrosion rate, and the atmospheric “corrosivity” for each exposure environment showed highly dynamic changes from the C1 to CX level (according to the ISO 9223 standard). A random forest model was developed to predict the corrosion rate and investigate the impacts of ten “corrosive factors” in dynamic atmospheres. The results reveal rust layer, wind speed, rainfall rate, RH, and chloride concentration, played a significant role in the corrosion process.


2022 ◽  
pp. 074873042110597
Author(s):  
Nathan J. Klett ◽  
Olga Cravetchi ◽  
Charles N. Allen

Both inhibitory and excitatory GABA transmission exist in the mature suprachiasmatic nucleus (SCN), the master pacemaker of circadian physiology. Whether GABA is inhibitory or excitatory depends on the intracellular chloride concentration ([Cl−]i). Here, using the genetically encoded ratiometric probe Cl-Sensor, we investigated [Cl−]i in AVP and VIP-expressing SCN neurons for several days in culture. The chloride ratio (RCl) demonstrated circadian rhythmicity in AVP + neurons and VIP + neurons, but was not detected in GFAP + astrocytes. RCl peaked between ZT 7 and ZT 8 in both AVP + and VIP + neurons. RCl rhythmicity was not dependent on the activity of several transmembrane chloride carriers, action potential generation, or the L-type voltage-gated calcium channels, but was sensitive to GABA antagonists. We conclude that [Cl−]i is under circadian regulation in both AVP + and VIP + neurons.


2022 ◽  
Vol 9 ◽  
Author(s):  
Mayumi Kawase ◽  
Masato Ogawa ◽  
Takayuki Hoshina ◽  
Masumi Kojiro ◽  
Miyuki Nakakuki ◽  
...  

Cystic fibrosis (CF) is a rare disease in the Japanese. The most common CFTR variant in Japanese CF patients is a large heterozygous deletion that can easily avoid detection by standard gene sequencing methods. We herein report a novel large heterozygous deletion in the CFTR gene in Japanese siblings with CF. A genetic analysis was performed in two patients (9-year-old boy and 5-month-old girl) who were clinically diagnosed with CF because of the positive result for the rapid fecal pancreatic elastase antigen test and the elevation of the sweat chloride concentration. In addition to conventional polymerase chain reaction (PCR) and direct sequencing, multiplex ligation-dependent probe amplification (MLPA) was performed to check for a large deletion and duplication of the CFTR gene. Based on MLPA findings, the breakpoint of heterozygous deletion was identified by real-time quantitative PCR followed by the sequence of the amplified junction fragment. In MLPA, the numbers of the fragments corresponding to exons 1, 16, 17a, and 17b and 234 nt and 747 nt upstream from the translation initiation codon of exon 1 in the CFTR gene and exon 3 in the ASZ1 gene were reduced by almost half. The c.2908+1085_3367+260del7201 variant (exon 16-17b deletion) was identified in one allele. The other allele had a large 137,567-bp deletion from g.117,361,112 (ASZ1 3′ flanking region) to g.117,498,678 (CFTR intron 1) on chromosome 7. Since the deletion variant lacked the entire promoter region of CFTR, CFTR mRNA would not be transcribed from the allele, indicating it to be a novel pathogenic variant causing CF. As large mutations are frequently detected in Japanese CF patients, MPLA can be useful when searching for variants.


2022 ◽  
Author(s):  
Mohd Sayeed Ul Hasan ◽  
Abhishek Kumar Rai

Abstract The north Indian Ganga basin is one of the densely populated basins of the world. Most agricultural and industrial contaminants drained throughout the river length are likely to be accumulated in the lower part of the Ganga basin. We used ten derived irrigation suitability parameters, which are obtained from 495 sampling points locations, besides using long term climate data (GLDAS_NOAH025_M) using “Technique for Order of Preference by Similarity to Ideal Solution” (TOPSIS) model to get the irrigation suitability map. Multi-Criteria Decision Making (MCDM) using TOPSIS helps make the best choices from the available finite number of alternatives based on their ranking. The obtained entropy weight for irrigation suitability parameters such as Electrical Conductivity (Ec), Sodium Adsorption Ratio (SAR), Magnesium Hardness (MH), Sodium Percent (Na%), Total Hardness (TH), Kelly’s ratio (KR), Permeability Index (PI), Chloride concentration (Cl−), Groundwater Level Fluctuation (GWLF), and lang factor (Df) are found to be 0.08, 0.14, 0.02, 0.02, 0.04, 0.08, 0.01, 0.32, 0.29 and 0.01 respectively. We find that SAR, Cl−, and GWLF controls the water quality for irrigation in the Lower Ganga basin since these parameters have relatively higher entropy weights (more than 0.10). The results obtained from the computed performance index or the closeness coefficient show that the area percent having very good, good, and very poor groundwater quality in the Lower Ganga basin is 34.67%,42.36%, and 22.97%, respectively. The LULC change pattern indicates that the percentage change of water and agricultural land was -11.96 and -0.86%, whereas an increase in the settlement area of 131.42% for the period between 2000 and 2015.


Electroless nickel-boron binary coatings were obtained with various bath compositions to investigate the effect of bath parameters on tribological and mechanical behaviours of the coating. Characterisation of the coating for surface morphology and phase structure is done using Scanning Electron Microscopy (SEM) and X-ray Diffraction (XRD), respectively, whereas tribological behaviour of coatings is evaluated on a pin-on-disc tribo-tester. Elastic modulus and surface hardness of coatings have been obtained using nano-indentation technique, while the scratch behaviour of the coatings has been determined using micro-scratch test. Corrosion resistance of coatings is also determined. It is observed that surface roughness of the coatings increased with increase in sodium borohydride concentration but decreased slightly with increase in nickel chloride concentration. Friction and wear characteristics are found to increase with surface roughness which occurs due to increased boron content. Surface hardness and scratch hardness are also seen to vary with coating bath parameters.


Author(s):  
Vinícius de Barros Souza ◽  
Edson Denner Leonel

Abstract Reinforcement corrosion is a concern in the structural engineering domain, since it triggers several pathological manifestations, reducing the structural service life. Chloride diffusion has been considered one of main causes of reinforcements' corrosion in reinforced concrete. Corrosion starts when the chloride concentration at the reinforcements interface reaches the threshold content, leading to depassivation, whose assessment of its time of starts is a major challenge. This study applied the transient Boundary Element Method (BEM) approach for modelling chloride diffusion in concrete pores. The subregion BEM technique effectively represented the cracks inherent to the material domain, and environmental effects were also considered. Because of the inherent randomness of the problem, the service life was evaluated within the probabilistic context; therefore, Monte Carlo Simulation (MCS) assessed the probabilistic corrosion time initiation. Three applications demonstrated the accuracy and robustness of the model, in which the numerical results achieved by BEM were compared against numerical, analytical, and experimental responses from the literature. The probabilistic modelling substantially reduced the structural service life when the cracks length was longer than half of concrete cover thickness in highly aggressive environments.


RSC Advances ◽  
2022 ◽  
Vol 12 (3) ◽  
pp. 1855-1861
Author(s):  
Duohua Xu ◽  
Jidan Li ◽  
Chunyuan Liang ◽  
Jincheng Liu ◽  
Hongtao Wang ◽  
...  

Electroless deposition of metallic Cr on an Al substrate proves the thermodynamic feasibility of Cr electroplating.


2022 ◽  
Vol 16 ◽  
pp. 175346662110701
Author(s):  
Marcella Burghard ◽  
Tim Takken ◽  
Merel M. Nap-van der Vlist ◽  
Sanne L. Nijhof ◽  
C. Kors van der Ent ◽  
...  

Objectives: [1] To investigate the cardiorespiratory fitness (CRF) levels in children and adolescents with cystic fibrosis (CF) with no ventilatory limitation (ventilatory reserve ⩾ 15%) during exercise, and [2] to assess which physiological factors are related to CRF. Methods: A cross-sectional study design was used in 8- to 18-year-old children and adolescents with CF. Cardiopulmonary exercise testing was used to determine peak oxygen uptake normalized to body weight as a measure of CRF. Patients were defined as having ‘low CRF’ when CRF was less than 82%predicted. Physiological predictors used in this study were body mass index z-score, P. Aeruginosa lung infection, impaired glucose tolerance (IGT) including CF-related diabetes, CF-related liver disease, sweat chloride concentration, and self-reported physical activity. Backward likelihood ratio (LR) logistic regression analysis was used. Results: Sixty children and adolescents (51.7% boys) with a median age of 15.3 years (25th–75th percentile: 12.9–17.0 years) and a mean percentage predicted forced expiratory volume in 1 second of 88.5% (±16.9) participated. Mean percentage predicted CRF (ppVO2peak/kg) was 81.4% (±12.4, range: 51%–105%). Thirty-three patients (55.0%) were classified as having ‘low CRF’. The final model that best predicted low CRF included IGT ( p = 0.085; Exp(B) = 6.770) and P. Aeruginosa lung infection (p = 0.095; Exp(B) = 3.945). This model was able to explain between 26.7% and 35.6% of variance. Conclusions: CRF is reduced in over half of children and adolescents with CF with normal ventilatory reserve. Glucose intolerance and P. Aeruginosa lung infection seem to be associated to low CRF in children and adolescents with CF.


Materials ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 144
Author(s):  
Jamal Choucri ◽  
Andrea Balbo ◽  
Federica Zanotto ◽  
Vincenzo Grassi ◽  
Mohamed Ebn Touhami ◽  
...  

Duplex α + β’ brasses are widely used in drinking water distribution systems for tube fittings, valves, and ancillaries because they are low cost, easy to fabricate, and exhibit high mechanical strength. However, depending on application conditions and alloy composition, they may undergo dealloying and stress corrosion cracking. In this research, three different brass types, two leaded (CW617N and CW602N) alloys and one lead-free brass (CW724R), were investigated to assess their corrosion behavior and susceptibility to stress corrosion cracking (SCC) in simulated drinking water (SDW) solutions containing different chloride concentrations, compatible with drinking water composition requirements according to Moroccan standard NM 03.7.001. The corrosion behavior was assessed by electrochemical tests such as polarization curve recording and electrochemical impedance spectroscopy (EIS) monitoring, coupled to SEM-EDS surface observations. The susceptibility to SCC was investigated by slow strain rate tests (SSRT). The tests showed that corrosion was mainly under diffusion control and chlorides slightly accelerated corrosion rates. All alloys, and particularly CW617N, were affected by SCC under the testing conditions adopted and in general the SCC susceptibility increased at increasing chloride concentration.


Sign in / Sign up

Export Citation Format

Share Document