Disposition and metabolism of the flavonoid chrysin in normal volunteers

2001 ◽  
Vol 51 (2) ◽  
pp. 143-146 ◽  
Author(s):  
T. Walle, ◽  
Y. Otake, ◽  
J. A. Brubaker, ◽  
U. K. Walle ◽  
P. V. Halushka
Keyword(s):  
1980 ◽  
Vol 43 (02) ◽  
pp. 131-132 ◽  
Author(s):  
Barbara Bain ◽  
T Forster

SummaryThe bleeding time by a modified Ivy technique was estimated on 128 normal volunteers, 59 men and 69 women. The bleeding time was found to be significantly longer in women than men (p<.001). This was not attributable to a difference in platelet count nor to any detectable difference in platelet aggregability. It is likely that a difference in blood vessels or supporting tissues is responsible for the observed difference.


1966 ◽  
Vol 16 (01/02) ◽  
pp. 038-050 ◽  
Author(s):  
Ulla Hedner ◽  
Inga Marie Nilsson ◽  
B Robertson

SummaryThe plasminogen content was determined by a casein method in plasma and serum from 20 normal volunteers. The mean plasminogen content was found to be 10.1 ACU (the arbitrary caseinolytic unit defined in such a way that using a 3% casein solution and a digestion time of 20 min. at 37°C, 10 ACU gave an extinction of 0.300). No difference between serum and plasma regarding the plasminogen content was found.Plasminogen was determined in drained and drained plus washed clots prepared from 2 ml plasma. The highest values found in the drained clots were 0.9 ACU/clot and 0.2 ACU/clot in the drained plus washed clots.Plasminogen was also determined in drained and drained plus washed clots prepared from plasma with added purified plasminogen. The plasminogen was recovered in the washing fluid. According to these tests, then, purified added plasminogen is washed out of the clots.The plasminogen content of 20 thrombi obtained post mortem was also determined. The mean value was found to be 0.7 ACU/cm thrombus. Judging from our results, the “intrinsic clot lysis theory” is not the main mechanism of clot dissolution.


2008 ◽  
Vol 21 (2) ◽  
pp. 126
Author(s):  
Joon Ho Lee ◽  
Jae Hwa Yoo ◽  
Sung Hwan Cho ◽  
Yong Ik Kim

1987 ◽  
Vol 115 (2) ◽  
pp. 235-242 ◽  
Author(s):  
Y. Reznik ◽  
B. P. Winiger ◽  
M. L. Aubert ◽  
P. C. Sizonenko

Abstract. The disappearance rate of [D-Ser(t-bu)6,des-Gly10]GnRH ethylamide (Buserelin®, HOE 766) was studied in plasma and urine after intranasal (300 μg) or sc (10 μg/kg) administration. A radioimmunoassay for HOE 766 was developed using 125I[D-Trp6,Des-Gly10]GnRH ethylamide as tracer and an antiserum raised against HOE 766. Cross-reaction with native GnRH was only 1.7%. Sensitivity was 1 pg/tube. In 6 male adolescents, the mean plasma HOE 766 concentration (± sem) was 0.46 ± 0.08, 0.50 ± 0.10, 0.28 ± 0.04, 0.24 ± 0.04, 0.13 ± 0.03, and 0.08 ± 0.02 μg/l 30, 60, 90, 120 and 180 min after the intranasal administration, respectively. Concomitant urinary excretion of HOE 766-like material was 9.43 ± 1.96 μg/4 h. There was a good correlation between integrated plasma levels and urinary excretion (r = 0.92). In the same 6 volunteers, the plasma HOE 766 levels were 21.2 ± 3.0, 25.9 ± 0.8, 21.2 ± 0.9, 17.1 ± 0.7, 12.8 ± 1.1, 8.9 ± 0.4, and 5.9 ± 0.8 μg/l 20, 40, 60, 90, 120, 180 and 240 min after sc injection, respectively. The mean urinary excretion was 543 ± 61 μg/4 h. In two girls with precocious puberty treated during 12 to 15 months with intranasal administration of HOE 766, urinary excretion of HOE 766-like material was shown to correlate well with the degree of inhibition of plasma 17β-E2and of plasma LH and FSH responses to a GnRH challenge. Thus, monitoring of HOE 766 in urine appears to be helpful for evaluating of intranasal therapy with a GnRH analog in precocious puberty.


1978 ◽  
Vol 24 (12) ◽  
pp. 2155-2157 ◽  
Author(s):  
T L Peeters ◽  
Y R Depraetere ◽  
G R Vantrappen

Abstract We present a radioimmunoassay for lysozyme in human serum, based upon human lysozyme isolated from the urine of leukemic patients and antiserum prepared against this lysozyme in the goat. In the separation step, a second antibody is used. By properly adjusting the concentrations of unlabeled and 125I-labeled lysozyme and of the antibodies, maximal precision (SD, 0.04 mg/litre) was obtained in the range 0.00 to 2.00 mg/litre. In 20 normal volunteers the lysozyme concentration was 4.6 +/- 0.8 mg/litre (mean +/- SD), in 13 patients with monocytic leukemia 34.4 +/- 8.6 mg/litre. Correlation with lysoplate determinations was excellent in leukemic sera (r = 0.97) but was poor in normal sera (r = 0.35), possibly owing to the existence of isoenzymes.


Sign in / Sign up

Export Citation Format

Share Document