Peak power detection of PS solar PV panel by using WPSCO

2017 ◽  
Vol 11 (4) ◽  
pp. 480-489 ◽  
Author(s):  
Nishant Kumar ◽  
Ikhlaq Hussain ◽  
Bhim Singh ◽  
Bijay Ketan Panigrahi
Keyword(s):  
Solar Pv ◽  
2018 ◽  
Vol 7 (2.17) ◽  
pp. 70
Author(s):  
Jaiganesh K ◽  
Karuppiah N ◽  
Ravivarman S ◽  
Md Asif

The maximum electrical energy conversion efficiency of the Solar PV panel is up to 22% in normal conventional roof- top system under the temperature of 25˚C on Standard Test Condition (STC). In Indian climatic conditions, the atmospheric temperature is mostly above 35˚C to 45˚C, it incites 35˚C to 80˚C temperature on the PV panel. The black body of the PV panel absorbs more heat. This temperature affects the electrical efficiency of the panel significantly. This paper proposes the mathematical modelling of the solar PV panel for different solar irradiation and the temperature. The experimental evaluation is conducted in the latitude of 11.36 (N) and longitude 77.82 (E). The testing and monitoring was done with LabVIEW based National Instruments hardware such as NI cDAQ-9178, NI DAQ - 9227 and NI DAQ 9225. The comparative study between the simulated result and real time hardware results are discussed in this paper. The test result shows that the output of the proposed model mismatches with the experimental output of the solar PV panel due to the negative correlation between the efficiency and temperature for variable irradiation condition. It shows a power difference of 9.41W between the output of the proposed model and the experimental setup.  


Implementation of modified AHP coupled with MOORA methods for modeling and optimization of solar photovoltaic (PV)-pumped hydro energy storage (PHS) system parameter is presented in this chapter. Work optimized the parameters, namely unmet energy (UE), size of PV-panel, and volume of upper reservoir (UR), to get economic cost of energy (COE) and excess energy (EE). The trail no.11 produces the highest assessment values compared to the other trails and provides EE as 16.19% and COE as 0.59 $/kWh for PV-PHS. ANOVA and parametric study is also performed to determine the significance of the parameters for PV-PHS performance. Investigation results indicate the effectiveness and significant potential for modeling and optimization of PV-PHS system and other solar energy systems.


2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Ridwone Hossain ◽  
Al Jumlat Ahmed ◽  
Sheik Md Kazi Nazrul Islam ◽  
Nirupam Saha ◽  
Preetom Debnath ◽  
...  

Solar photovoltaic (PV) and solar thermal systems are most widely used renewable energy technologies. Theoretical study indicates that the energy conversion efficiency of solar photovoltaic gets reduced about 0.3% when its temperature increases by 1°C. In this regard, solar PV and thermal (PVT) hybrid systems could be a solution to draw extra heat from the solar PV panel to improve its performance by reducing its temperature. Here, we have designed a new type of heat exchanger for solar PV and thermal (PVT) hybrid systems and have studied the performance of the system. The PVT system has been investigated in comparison with an identical solar PV panel at outdoor condition at Dhaka, Bangladesh. The experiments show that the average improvement of open circuit voltage (Voc) is 0.97 V and the highest improvement of Voc is 1.3 V. In addition, the overall improvement of output power of solar PV panel is 2.5 W.


Author(s):  
G Anilkumar ◽  
K Naveen ◽  
M T V S H K Pavan Kumar ◽  
G V Brahmendra Kumar ◽  
K Palanisamy ◽  
...  

2018 ◽  
Vol 225 ◽  
pp. 04008 ◽  
Author(s):  
Shaharin A. Sulaiman ◽  
M. Rosman M. Razif ◽  
Tan Dei Han ◽  
Samson M. Atnaw ◽  
S. Norazilah A. Tamili

There are some weaknesses of using solar PV system especially when there is issue of soiling on the surface of solar PV panel. The consequences for absence of this such study can cause unanticipated cost in the operation of solar PV panel. The objective of this project is to study the trend of soiling rate over different time period and its effect on the performance of solar PV panel in Malaysia and to develop a simple prediction model for cleaning interval of solar PV system in Malaysia. The study was conducted on real-time basis on a building’s roof. Measurements of solar irradiance, voltage, current and the mass of dust collected were performed from both clean and dirty panels. It was discovered that the Monthly Test was significant with 4.53% of performance drop. Further analysis was conducted by running prediction model for cleaning interval. Intersection of graph plotting and fixed cleaning cost gives answer of cleaning interval that can be performed. It can be concluded that for every two and half month is the recommended time interval to perform regular cleaning to maximise electrical power generation by solar PV system in Malaysia.