scholarly journals Improvement of 93mNb and 103mRh activity measurement methodology for reactor dosimetry

2017 ◽  
Vol 153 ◽  
pp. 07009 ◽  
Author(s):  
J. Riffaud ◽  
M.-C. Lépy ◽  
C. Domergue ◽  
H. Philibert ◽  
C. Destouches ◽  
...  
Sports ◽  
2021 ◽  
Vol 9 (5) ◽  
pp. 69
Author(s):  
Yi-Shin Lee ◽  
John Komar ◽  
Michael Yong Hwa Chia

Non-communicable diseases (NCDs) are a preventable threat to livelihood and longevity in the Association of South East Asian Nations (ASEAN) and insufficient physical activity (PA) is a primary cause of NCDs. A PRISMA-based systematic review of measurement methodologies used to assess PA was conducted. 564 studies published between 1978 and 2020 were reviewed. The majority of the PA measurement employed subjective methodologies and were observational and cross-sectional, with disproportionately fewer studies conducted in economically-challenged member nations, except for Brunei. PA research in Brunei, Cambodia, Laos and Myanmar constituted 0.4–1.1% while Malaysia, Singapore, Thailand and Indonesia contributed 12–37% of all PA research within ASEAN. A decision matrix can be used to determine the measurement methodology of choice to assess PA. Joint research across ASEAN using a common assessment or measurement template that is co-curated by ASEAN researchers that incorporates multi-level and whole-of-society criteria in terms of PA enablers is a recommendation. This could be co-led by more experienced and better-resourced countries so as to produce a unified and universal ‘report card’ for PA measurement within ASEAN.


1983 ◽  
Vol 50 (02) ◽  
pp. 563-566 ◽  
Author(s):  
P Hellstern ◽  
K Schilz ◽  
G von Blohn ◽  
E Wenzel

SummaryAn assay for rapid factor XIII activity measurement has been developed based on the determination of the ammonium released during fibrin stabilization. Factor XIII was activated by thrombin and calcium. Ammonium was measured by an ammonium-sensitive electrode. It was demonstrated that the assay procedure yields accurate and precise results and that factor XIII-catalyzed fibrin stabilization can be measured kinetically. The amount of ammonium released during the first 90 min of fibrin stabilization was found to be 7.8 ± 0.5 moles per mole fibrinogen, which is in agreement with the findings of other authors. In 15 normal subjects and in 15 patients suffering from diseases with suspected factor XIII deficiency there was a satisfactory correlation between the results obtained by the “ammonium-release-method”, Bohn’s method, and the immunological assay (r1 = 0.65; r2= 0.70; p<0.01). In 3 of 5 patients with paraproteinemias the values of factor XIII activity determined by the ammonium-release method were markedly lower than those estimated by the other methods. It could be shown that inhibitor mechanisms were responsible for these discrepancies.


TAPPI Journal ◽  
2012 ◽  
Vol 11 (8) ◽  
pp. 51-58
Author(s):  
ANTTI HAAPALA ◽  
MIKA KÖRKKÖ ◽  
ELISA KOIVURANTA ◽  
JOUKO NIINIMÄKI

Analysis methods developed specifically to determine the presence of ink and other optically active components in paper machine white waters or other process effluents are not available. It is generally more interest¬ing to quantify the effect of circulation water contaminants on end products. This study compares optical techniques to quantify the dirt in process water by two methods for test media preparation and measurement: direct process water filtration on a membrane foil and low-grammage sheet formation. The results show that ink content values obtained from various analyses cannot be directly compared because of fundamental issues involving test media preparation and the varied methodologies used to formulate the results, which may be based on different sets of assumptions. The use of brightness, luminosity, and reflectance and the role of scattering measurements as a part of ink content analysis are discussed, along with fine materials retention and measurement media selection. The study concludes with practical tips for case-dependent measurement methodology selection.


2013 ◽  
Vol 18 (2-3) ◽  
pp. 33-41
Author(s):  
Dominik Sankowski ◽  
Marcin Bakala ◽  
Rafał Wojciechowski

Abstract The good quality of several manufactured components frequently depends on solidliquid interactions existing during processing. Nowadays, the research in material engineering focuses also on modern, automatic measurement methods of joining process properties, i.a. wetting force and surface tension, which allows for quantitative determination of above mentioned parameters. In the paper, the brazes’ dynamic properties in high-temperatures’ measurement methodology and the stand for automatic determination of braze’s properties, constructed and implmented within the research grant nr KBN N N519 441 839 - An integrated platform for automatic measurement of wettability and surface tension of solders at high temperatures, are widely described


Sign in / Sign up

Export Citation Format

Share Document