RESISTIVITY OF LIQUID Ga BETWEEN 303 K AND 573 K FROM STRUCTURE FACTOR MEASURENENTS

1980 ◽  
Vol 41 (C8) ◽  
pp. C8-262-C8-265 ◽  
Author(s):  
M. C. Bellissent-Funel ◽  
R. Bellissent ◽  
G. Tourand
Keyword(s):  
1990 ◽  
Vol 51 (20) ◽  
pp. 2373-2385 ◽  
Author(s):  
F. Schosseler ◽  
M. Daoud ◽  
L. Leibler

1985 ◽  
Vol 46 (C8) ◽  
pp. C8-281-C8-286 ◽  
Author(s):  
C. Tête ◽  
D. Boumazouza ◽  
G. Marchal ◽  
Ph. Mangin ◽  
J. Bouillot ◽  
...  

2021 ◽  
Vol 23 (15) ◽  
pp. 9061-9064
Author(s):  
Ralph A. Wheeler ◽  
Emily E. Dalbey

Fitting X-ray structure factor lineshapes from experiment or simulation quantifies the nanoscale range of charge alternation in the title compound.


Polymers ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 167
Author(s):  
Weiguang An ◽  
Lujun Peng ◽  
Minglun Cai ◽  
Kaiyang Hu ◽  
Song Li ◽  
...  

Polymethyl methacrylate plates are widely applied to buildings, producing significant fire hazards. It lacks a theoretical basis for the fire risk assessment of polymethyl methacrylate in concave building facades. Therefore, experimental methods are used to investigate combustion characteristics of discrete polymethyl methacrylate plates in a concave building facade. Influences of fuel coverage and structure factor are investigated, which is scant in previous works. When structure factor is invariable, average flame height increases first and then decreases as fuel coverage increases, and the turning point is between 0.64 and 0.76. In total, three different patterns of pyrolysis front propagation are first observed for different fuel coverages. Flame spread rate first increases and then decreases as fuel coverage rises, and the turning point is also between 0.64 and 0.76. When fuel coverage is invariable, the flame spread rate first increases and then decreases with increasing structure factor, and the turning point is 1.2. A model for predicting the flame spread rate of discrete polymethyl methacrylate is also developed. The predicted values are consistent with experimental results. Fuel spread rate of discrete polymethyl methacrylate rises as the fuel coverage increases. The above results are beneficial for thermal hazard evaluation and fire safety design of polymethyl methacrylate used in buildings.


1980 ◽  
Vol 40 (6) ◽  
pp. 1517-1521 ◽  
Author(s):  
C.S. Murthy ◽  
K. Singer ◽  
M.L. Klein ◽  
I.R. McDonald

2016 ◽  
Vol 49 (6) ◽  
pp. 2354-2364 ◽  
Author(s):  
Arantxa Arbe ◽  
José A. Pomposo ◽  
Isabel Asenjo-Sanz ◽  
Debsindhu Bhowmik ◽  
Oxana Ivanova ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document