scholarly journals Design and Implementation of Electronically Controlled On-off Prism based on WSNs

2018 ◽  
Vol 173 ◽  
pp. 01031
Author(s):  
Wei Guo ◽  
Yun Bai ◽  
Peng Zhang ◽  
Xiaolu Liu

Aiming at the problem of multiple prisms recognition in a narrow field angle in the application of TPS automatic measurement, a novel prism node is designed and implemented. Based on WSNs, measuring prism and electrically controlled dimming glass are grouped together as a prism node. It can easily switch between the fuzzy or the transparent state, to help TPS search and observe the correct prism automatically. Its feasibility is verified by experiments, which greatly simplifies the complexity of engineering installation and operation.

2017 ◽  
Vol 37 (1) ◽  
pp. 75
Author(s):  
Asdrubal Antonio Ramirez Botero ◽  
Gerardo Gordillo

This paper presents details of the design and implementation of a system for measuring of thermally stimulated current (TSC) and transient photocurrent (Iph), developed using the Virtual Instrumentation concept. For that we have used National Instrument hardware and the LabView® package as software. The system is controlled by a virtual instrument (VI) which includes facilities to perform measurements of photocurrent keeping the temperature of the sample and the pressure of the chamber of measurement controlled as well as  real time display of the Iph vs t and TSC vs T curves. The system was tested by performing transient photocurrent and TSC measurements on CH3NH3PbI3 thin films that are generally used as absorbent layer of solar cells. This type of characterization is very useful to get information of the  trapping and recombination processes that affect the transport properties of the devices.


Author(s):  
J. C. Russ ◽  
T. Taguchi ◽  
P. M. Peters ◽  
E. Chatfield ◽  
J. C. Russ ◽  
...  

Conventional SAD patterns as obtained in the TEM present difficulties for identification of materials such as asbestiform minerals, although diffraction data is considered to be an important method for making this purpose. The preferred orientation of the fibers and the spotty patterns that are obtained do not readily lend themselves to measurement of the integrated intensity values for each d-spacing, and even the d-spacings may be hard to determine precisely because the true center location for the broken rings requires estimation. We have implemented an automatic method for diffraction pattern measurement to overcome these problems. It automatically locates the center of patterns with high precision, measures the radius of each ring of spots in the pattern, and integrates the density of spots in that ring. The resulting spectrum of intensity vs. radius is then used just as a conventional X-ray diffractometer scan would be, to locate peaks and produce a list of d,I values suitable for search/match comparison to known or expected phases.


2015 ◽  
Vol 24 (3) ◽  
pp. 106-113 ◽  
Author(s):  
Stephen N. Calculator

Purpose To provide an overview of communication characteristics exhibited by individuals with Angelman Syndrome (AS) and special considerations associated with the design and implementation of augmentative and alternative communication (AAC) programs. Method Results of recent studies exploring individuals' uses of AAC are reviewed, with particular emphasis on factors related to individuals' acceptance and successful uses of AAC systems. Results Not applicable Conclusion Despite their inconsistent access to practices previously found to foster individuals' acceptance of AAC systems, individuals with AS demonstrate the ability to use AAC systems, including high-tech AAC devices, successfully.


VASA ◽  
2005 ◽  
Vol 34 (4) ◽  
pp. 255-261 ◽  
Author(s):  
Diehm ◽  
Baumgartner ◽  
Silvestro ◽  
Herrmann ◽  
Triller ◽  
...  

Background: Open surgical or endovascular abdominal aortic aneurysm (AAA) relies on precise preprocedual imaging. Purpose of this study was to assess inter- and intraobserver variation of software-supported automated and manual multi row detector CT angiography (MDCTA) in aortoiliac diameter measurements before AAA repair. Patients and methods: Thirty original MDCTA data sets (4 times 2mm collimation) of patients scheduled for endovascular AAA repair were studied on a dedicated software capable of creating two-dimensional reformatted planes orthogonal to the aortoiliac center-line. Measurements were performed twice with a four-week interval between readings. Data were analysed by two blinded readers at random order. Two different measurement methods were performed: reader-assisted freehand wall-to-wall measurement and semi-automatic measurement. Results: Aortoiliac diameters were significantly underestimated by the semi-automatic method as compared to reader-assisted measurements (p < 0.0031). Intraobserver variability of AAA diameter calculation was not significant (p > 0.15) for reader-assisted measurements except for the diameter of the left common iliac artery in reader 2 (p = 0.0045) and it was not significant (p > 0.14) using the semi-automatic method. Interobserver variability was not significant for AAA diameter measurements using the reader-assisted method and for proximal neck analysis with the semi-automatic method (p > 0.27). Relevant interobserver variation was observed for semi-automatic measurement of maximum AAA (p = 0.0007) and iliac artery diameters (p = 0.024). Conclusions: Dedicated MDCTA software provides a useful tool to minimize aortoiliac diameter measurement variation and to improve imaging precision before AAA repair. For reliable AAA diameter analysis the reader-assisted freehand measurement method is recommended to be applied to a set of reformatted CT data as provided by the software used in this study.


2017 ◽  
Author(s):  
Alicia Papas ◽  
Anthony D. LaMontagne ◽  
Allison J. Milner ◽  
Amanda Allisey ◽  
Andrew J. Noblet ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document