A New Technique With Sodium Hypochlorite to Increase Bracket Shear Bond Strength of Fluoride-releasing Resin-modified Glass Ionomer Cements: Comparing Shear Bond Strength of Two Adhesive Systems With Enamel Surface Deproteinization Before Etching

2010 ◽  
Vol 16 (1) ◽  
pp. 66-75 ◽  
Author(s):  
Roberto Justus ◽  
Tatiana Cubero ◽  
Ricardo Ondarza ◽  
Fernando Morales
2012 ◽  
Vol 17 (6) ◽  
pp. 154-159 ◽  
Author(s):  
Marcel M. Farret ◽  
Eduardo Martinelli de Lima ◽  
Eduardo Gonçalves Mota ◽  
Hugo Mitsuo S. Oshima ◽  
Gabriela Maguilnik ◽  
...  

OBJECTIVE: To evaluate the mechanical properties of three glass ionomers cements (GICs) used for band cementation in Orthodontics. METHODS: Two conventional glass ionomers (Ketac Cem Easy mix/3M-ESPE and Meron/Voco) and one resin modified glass ionomer (Multi-cure Glass ionomer/3M-Unitek) were selected. For the compressive strength and diametral tensile strength tests, 12 specimens were made of each material. For the microhardness test 15 specimens were made of each material and for the shear bond strength tests 45 bovine permanent incisors were used mounted in a self-cure acrylic resin. Then, band segments with a welded bracket were cemented on the buccal surface of the crowns. For the mechanical tests of compressive and diametral tensile strength and shear bond strength a universal testing machine was used with a crosshead speed of 1,0 mm/min and for the Vickers microhardness analysis tests a Microdurometer was used with 200 g of load during 15 seconds. The results were submitted to statistical analysis through ANOVA complemented by Tukey's test at a significance level of 5%. RESULTS: The results shown that the Multi-Cure Glass Ionomer presented higher diametral tensile strength (p < 0.01) and compressive strength greater than conventional GICs (p = 0.08). Moreover, Ketac Cem showed significant less microhardness (p < 0.01). CONCLUSION: The resin-modified glass ionomer cement showed high mechanical properties, compared to the conventional glass ionomer cements, which had few differences between them.


10.2341/05-13 ◽  
2006 ◽  
Vol 31 (2) ◽  
pp. 212-218 ◽  
Author(s):  
A. E. Souza-Gabriel ◽  
F. L. B. Amaral ◽  
J. D. Pécora ◽  
R. G. Palma-Dibb ◽  
S. A. M. Corona

Clinical Relevance Er:YAG laser adversely affected the adhesion of resin-modified glass ionomer cements to tooth structure and cannot be considered an alternative technique to the conventional turbine handpiece.


2018 ◽  
Vol 29 (2) ◽  
pp. 128-132 ◽  
Author(s):  
Gabriela Cristina Santin ◽  
Alexandra Mussolino de Queiroz ◽  
Regina Guenka Palma-Dibb ◽  
Harley Francisco de Oliveira ◽  
Paulo Nelson Filho ◽  
...  

Abstract Patients undergoing radiotherapy treatment present more susceptibility to dental caries and the use of an orthodontic device increases this risk factor due to biofilm accumulation around the brackets. The objective of this study was to evaluate the shear bond strength to irradiated permanent teeth of orthodontic brackets bonded with conventional glass ionomer cement and resin-modified glass ionomer cement due to the fluoride release capacity of these materials. Ninety prepared human premolars were divided into 6 groups (n=15), according to the bonding material and use or not of radiation: CR: Transbond XT composite resin; RMGIC: Fuji Ortho LC conventional glass ionomer cement; GIC: Ketac Cem Easymix resin-modified glass ionomer cement. The groups were irradiated (I) or non-irradiated (NI) prior to bracket bonding. The specimens were subjected to a fractioned radiation dose of 2 Gy over 5 consecutive days for 6 weeks. After the radiotherapy, the brackets were bonded on the specimens with Transbond XT, Fuji Ortho LC and Ketac Cem Easymix. After 24 h, the specimens were subjected to shear bond strength test. The image of enamel surface (classified by Adhesive Remnant Index - ARI) was also evaluated and its frequency was checked among groups/subgroups. The shear bond strength variable was evaluated with ANOVA and Tukey’s post-hoc test. GIC group showed the lowest adhesion values among the groups (p<0.05). There was no statistically significant difference among non-irradiated and irradiated groups (p>0.05). As for the ARI, the CR-I group showed the highest material retention on enamel surface among the irradiated groups. RMGIC group showed the highest values for shear bond strength and presented ARI acceptable for clinical practices.


2021 ◽  
Vol 14 (4) ◽  
pp. 1871-1876
Author(s):  
M.T. Maliael

This study was designed with the aim to evaluate the effect of curing time on the shear-bond strength of orthodontic brackets bonded using light cure Resin-Modified Glass Ionomer Cements (RMGIC). This class of cement when used for luting orthodontic brackets offers certain advantages when compared to the more commonly used resin cements. Intact natural teeth (premolars) extracted for therapeutic purposes as part of orthodontic treatment was sourced for use in this study. The teeth were equally divided into four groups four testing, Group 1 - brackets bonded with RMGIC and cured for 3 seconds, Group 2 - brackets bonded RMGIC and cured for 6 seconds, Group 3 - brackets bonded with RMGIC and cured for 9 seconds and Control group - brackets bonded with composite and cured for 15 seconds. A high intensity LED light source was used to cure the cements. The Shear-Bond strength of the brackets was evaluated using a universal testing machine. One-way ANOVA test and Tukey multiple comparison tests were done to compare the difference of Shear-Bond Strengths among the groups tested. The average Shear Bond Strength among study groups was 7.64±2.86 MPa. The ANOVA and Tukey multiple comparison tests could not identify a statistically significant difference in Shear-Bond Strengths among the groups. Curing time does not appear to have a statistically significant effect on the Shear Bond Strength of orthodontic brackets bonded using Resin-Modified Glass Ionomer Cements..


2020 ◽  
Vol 10 (22) ◽  
pp. 8157
Author(s):  
Encarna Piquer Maño ◽  
Rafael Marco Algarra ◽  
Amr Fawzy ◽  
Vicente C. B. Leitune ◽  
Fabrício M. Collares ◽  
...  

This study aimed at evaluating the shear bond strength (SBS) of modern self-adhesive resin cements and resin-modified glass ionomer cements applied to different prosthetic substrates. Zirconia, lithium-disilicate glass-ceramic and a noble metal alloy were used as bonding substrates. They were all sand-blasted with alumina, while LD was further etched with 9.6% hydrofluoric acid (10 s). A light-curing resin-modified glass ionomer cement (3M-GIC: Ketac Cem Plus) and a self-curing resin-modified glass ionomer cement (GC-GIC: FujiCEM 2) were compared to self-adhesive resin cements (PAN: Panavia SA Universal) and (3M-RES: Rely X Unicem 2). Ten specimens for each substrate were produced and up to five cylinders of each cement were bonded to each substrate. The shear bond strength (SBS) was evaluated after 24 h or after thermocycling (TC) aging (5000 cycles). The data was statistically analysed by two-way ANOVA and Student–Newman–Keuls test (α = 0.05). Failure modes were analysed through stereoscopic microscopy. The greatest SBS was attained with PAN, whilst 3M-GIC showed the lowest SBS and failed prevalently in adhesive mode. No difference in SBS was observed between GC-GIC and 3M-RES. After TC aging, all cements showed significant drop (p < 0.05) in SBS, but PAN showed the greatest SBS. Reliable bond strength to prosthetic substrates can be achieved with specific universal resin-luting cements and may be an alternative to glass ionomer cements when luting alloy substrates.


Author(s):  
Behrad Tanbakuchi ◽  
Tabassom Hooshmand ◽  
Mohammad Javad Kharazifard ◽  
Kiana Shekofteh ◽  
Arian Hesam Arefi

Objectives: This study aimed to assess the shear bond strength (SBS) of molar tubes to the enamel surface of molar teeth using a resin-modified glass ionomer (RMGI) cement modified with amorphous calcium phosphate (ACP). Materials and Methods: In this in-vitro study, 60 extracted human third molars were randomly divided into four groups for bonding of molar tubes to the enamel surface. Fuji Ortho LC and Fuji Ortho LC modified with ACP (1.55 wt%) were used in groups 1 and 2, respectively. In group 3, the enamel surface was sandblasted, and bonding was then performed using Fuji Ortho LC glass ionomer modified with ACP. In group 4, molar tubes were conventionally bonded using Transbond XT composite. The SBS was measured using a universal testing machine. Results: The mean SBS of groups 1 to 4 was 10.22, 6.88, 9.4, and 13.68 MPa, respectively. Only the SBS of group 1 was not significantly different from that of groups 3 and 4 (P>0.05). Comparison of adhesive remnant index (ARI) scores of the groups revealed significant differences only between groups 1 and 4 (P<0.001) and between groups 1 and 2 (P=0.002). Conclusion: The results revealed that the addition of ACP to Fuji Ortho LC significantly decreased the SBS of molar tubes bonded to enamel compared to the conventional resin bonding system. Sandblasting of the enamel surface significantly increased the bond strength. Fuji Ortho LC modified with ACP is recommended for bonding of molar tubes to posterior teeth considering its cariostatic property.


2011 ◽  
Vol 27 (2) ◽  
pp. 305-311 ◽  
Author(s):  
Elmira Jafari Navimipour ◽  
Siavash Savadi Oskoee ◽  
Parnian Alizadeh Oskoee ◽  
Mahmoud Bahari ◽  
Sahand Rikhtegaran ◽  
...  

2021 ◽  
Vol 12 (3) ◽  
pp. 42
Author(s):  
Whithipa Thepveera ◽  
Wisitsin Potiprapanpong ◽  
Arnit Toneluck ◽  
Somruethai Channasanon ◽  
Chutikarn Khamsuk ◽  
...  

The aim of this study was to prepare experimental resin-modified glass ionomer cements (RMGICs) containing low levels of hydroxyethyl methacrylate (HEMA) for pulp protection. Liquid and powder phases of the experimental RMGICs were polyacid functionalized with methacrylate groups and spherical pre-reacted glass fillers (SPG). Two types of liquid phase containing 0 wt. % HEMA (CM liquid) or 5 wt. % HEMA (CMH liquid) were formulated. The experimental RMGICs were prepared by mixing SPG fillers with CM liquid (F1) or CMH liquid (F2). Rheological properties were examined using a strain-controlled rheometer (n = 5). The Vickers microhardness (n = 5) and dentin shear bond strength (SBS) (n = 10) of the materials were tested. Commercial pulp protection materials (Vitrebond and TheraCal LC) were used as comparisons. The viscosity and surface microhardness of F1 (22 m Pa·s, 18 VHN) and F2 (18 m Pa·s, 16 VHN) were significantly higher than those of Vitrebond (6 mPa·s, 6 VHN) and TheraCal (0.1 mPa·s, 7 VHN). The SBS of F1 (10.7 MPa) and F2 (11.9 MPa) was comparable to that of Vitrebond (15.4 MPa) but higher than that of TheraCal LC (5.6 MPa). The addition of 5 wt. % HEMA showed no significant effect on viscosity, surface microhardness, or SBS of the experimental RMGICs. The experimental materials showed higher viscosity and microhardness but similar SBS when compared with the commercial RMGIC.


Sign in / Sign up

Export Citation Format

Share Document