Influence of PET/CT-introduction on PET scanning frequency and indications

2007 ◽  
Vol 46 (02) ◽  
pp. 57-64 ◽  
Author(s):  
A. Bockisch ◽  
S. M. Eschmann ◽  
B. J. Krause ◽  
R. Rödel ◽  
R. Tiling ◽  
...  

Summary Aim: To evaluate the influence of the introduction of combined PET/CT scanners into clinical routine. This investigation addresses the quantitative changes between PET/CT and stand alone PET. Methods: The study included all examinations performed on stand alone PET- or PET/CTscanners within 12 month prior to and after implementation of PET/CT. The final data analysis included five university hospitals and a total number of 15 497 exams. We distinguished exams on stand alone tomographs prior to and after installation of the combined device as well as PET/CT scans particularly with regard to disease entities. Various further parameters were investigated. Results: The overall number of PET scans (PET and PET/CT) rose by 146% while the number of scans performed on stand alone scanners declined by 22%. Only one site registered an increase in stand alone PET. The number of exams for staging in oncology increased by 196% while that of cardiac scans decreased by 35% and the number of scans in neurology rose by 47%. The use of scans for radiotherapy planning increased to 7% of all PET/CT studies. The increase of procedures for so-called classic PET oncology indications was moderate compared to the more common tumors. An even greater increase was observed in some rare entities. Conclusions: The introduction of PET/CT led to more than a doubling of overall PET procedures with a main focus on oncology. Some of the observed changes in scanning frequency may be caused by a rising availability of new radiotracers and advancements of competing imaging methods. Nevertheless the evident increase in the use of PET/CT for the most common tumour types demonstrates its expanding role in cancer staging. The combination of molecular and morphologic imaging has not only found its place but is still gaining greater importance with new developments in technology and radiochemistry.

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Daniëlle Koopman ◽  
Pieter L. Jager ◽  
Cornelis H. Slump ◽  
Siert Knollema ◽  
Jorn A. van Dalen

Abstract Background A high SUV-reproducibility is crucial when different PET scanners are in use. We evaluated the SUV variability in whole-body FDG-PET scans of patients with suspected or proven cancer using an EARL-accredited conventional and digital PET scanner. In a head-to-head comparison we studied images of 50 patients acquired on a conventional scanner (cPET, Ingenuity TF PET/CT, Philips) and compared them with images acquired on a digital scanner (dPET, Vereos PET/CT, Philips). The PET scanning order was randomised and EARL-compatible reconstructions were applied. We measured SUVmean, SUVpeak, SUVmax and lesion diameter in up to 5 FDG-positive lesions per patient. The relative difference ΔSUV between cPET and dPET was calculated for each SUV-parameter. Furthermore, we calculated repeatability coefficients, reflecting the 95% confidence interval of ΔSUV. Results We included 128 lesions with an average size of 19 ± 14 mm. Average ΔSUVs were 6-8% with dPET values being higher for all three SUV-parameters (p < 0.001). ΔSUVmax was significantly higher than ΔSUVmean (8% vs. 6%, p = 0.002) and than ΔSUVpeak (8% vs. 7%, p = 0.03). Repeatability coefficients across individual lesions were 27% (ΔSUVmean and ΔSUVpeak) and 33% (ΔSUVmax) (p < 0.001). Conclusions With EARL-accredited conventional and digital PET, we found a limited SUV variability with average differences up to 8%. Furthermore, only a limited number of lesions showed a SUV difference of more than 30%. These findings indicate that EARL standardisation works. Trial registration This prospective study was registered on the 31th of October 2017 at ClinicalTrials.cov. URL: https://clinicaltrials.gov/ct2/show/NCT03457506?id=03457506&rank=1.


2019 ◽  
Vol 58 (05) ◽  
pp. 371-378
Author(s):  
Alfred O. Ankrah ◽  
Ismaheel O. Lawal ◽  
Tebatso M.G. Boshomane ◽  
Hans C. Klein ◽  
Thomas Ebenhan ◽  
...  

Abstract 18F-FDG and 68Ga-citrate PET/CT have both been shown to be useful in the management of tuberculosis (TB). We compared the abnormal PET findings of 18F-FDG- and 68Ga-citrate-PET/CT in patients with TB. Methods Patients with TB on anti-TB therapy were included. Patients had a set of PET scans consisting of both 18F-FDG and 68Ga-citrate. Abnormal lesions were identified, and the two sets of scans were compared. The scan findings were correlated to the clinical data as provided by the attending physician. Results 46 PET/CT scans were performed in 18 patients, 11 (61 %) were female, and the mean age was 35.7 ± 13.5 years. Five patients also had both studies for follow-up reasons during the use of anti-TB therapy. Thirteen patients were co-infected with HIV. 18F-FDG detected more lesions than 68Ga-citrate (261 vs. 166, p < 0.0001). 68Ga-citrate showed a better definition of intracerebral lesions due to the absence of tracer uptake in the brain. The mean SUVmax was higher for 18F-FDG compared to 68Ga-citrate (5.73 vs. 3.01, p < 0.0001). We found a significant correlation between the SUVmax of lesions that were determined by both tracers (r = 0.4968, p < 0.0001). Conclusion Preliminary data shows 18F-FDG-PET detects more abnormal lesions in TB compared to 68Ga-citrate. However, 68Ga-citrate has better lesion definition in the brain and is therefore especially useful when intracranial TB is suspected.


2013 ◽  
Vol 04 (06) ◽  
pp. 253-259
Author(s):  
J. Jeong ◽  
E. Kong ◽  
K. Chun ◽  
B. Jang ◽  
T. Kim ◽  
...  

Summary Aim: With the recent advances in multidetector-row CT, a fusion of functional PET with three dimensional (3D) CT gastrography may provide enhanced diagnostic capability and help surgeons during preoperative planning. The diagnostic value of hybrid PET/CT gastrography was compared with that of conventional PET/CT alone in gastric cancer staging. Patients, methods: Patients with gastric cancer (n = 101) confirmed by endoscopic biopsy specimens underwent conventional PET/CT and regional PET with contrast enhanced CT, followed by gastrectomy with lymphadenectomy at our institution from November 2007 to November 2008. These images were fused into a hybrid PET/CT gastrography using the cardiac IQ fusion software. Conventional PET/CT and hybrid PET/ CT gastrography were evaluated for staging of gastric cancer. After gastrectomy, these were compared with pathologic reports respectively. Results: Gastric cancer was diagnosed as 50 early gastric cancer (EGC) and 51 advanced gastric cancer (AGC) on pathologic examination. In EGC, hybrid PET/CT gastrography and PET/CT identified 36 (72%) and 7 (14%) tumours, respectively. Hybrid PET/CT gastrography correctly delineated the subtype of 25 EGC. In AGC, all 51 (100%) tumours were identified on the hybrid PET/CT gastrography compared to 39 (76.5%) tumours on PET/CT. Hybrid PET/CT gastrography correctly classified the morphology of 42 AGC using the Bormann classification. Additionally, depth of invasion was correctly presented in 38 of 51 AGC. Hybrid PET/CT gastrography for regional lymph node (LN) metastasis in the EGC and AGC showed the sensitivity of 75% and 83.9%, and specificity 90.5% and 55%, respectively. Conclusion: Hybrid PET/CT gastrography is the more intuitive and comprehensive method for the preoperative evaluation of gastric cancer than conventional PET/CT.


Diagnostics ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 552
Author(s):  
Salam Awenat ◽  
Arnoldo Piccardo ◽  
Patricia Carvoeiras ◽  
Giovanni Signore ◽  
Luca Giovanella ◽  
...  

Background: The use of prostate-specific membrane antigen (PSMA)-targeted agents for staging prostate cancer (PCa) patients using positron emission tomography/computed tomography (PET/CT) is increasing worldwide. We performed a systematic review on the role of 18F-PSMA-1007 PET/CT in PCa staging to provide evidence-based data in this setting. Methods: A comprehensive computer literature search of PubMed/MEDLINE and Cochrane Library databases for studies using 18F-PSMA-1007 PET/CT in PCa staging was performed until 31 December 2020. Eligible articles were selected and relevant information was extracted from the original articles by two authors independently. Results: Eight articles (369 patients) evaluating the role of 18F-PSMA-1007 PET/CT in PCa staging were selected. These studies were quite heterogeneous, but, overall, they demonstrated a good diagnostic accuracy of 18F-PSMA-1007 PET/CT in detecting PCa lesions at staging. Overall, higher primary PCa aggressiveness was associated with higher 18F-PSMA-1007 uptake. When compared with other radiological and scintigraphic imaging methods, 18F-PSMA-1007 PET/CT had superior sensitivity in detecting metastatic disease and the highest inter-reader agreement. 18F-PSMA-1007 PET/CT showed similar results in terms of diagnostic accuracy for PCa staging compared with PET/CT with other PSMA-targeted tracers. Dual imaging with multi-parametric magnetic resonance imaging and 18F-PSMA-1007 PET/CT may improve staging of primary PCa. Notably, 18F-PSMA-1007-PET/CT may detect metastatic disease in a significant number of patients with negative standard imaging. Conclusions: 18F-PSMA-1007 PET/CT demonstrated a good accuracy in PCa staging, with similar results compared with other PSMA-targeted radiopharmaceuticals. This method could substitute bone scintigraphy and conventional abdominal imaging for PCa staging. Prospective multicentric studies are needed to confirm these findings.


Author(s):  
Stefan A. Koerber ◽  
R. Finck ◽  
K. Dendl ◽  
M. Uhl ◽  
T. Lindner ◽  
...  

Abstract Purpose A high expression of fibroblast activation protein (FAP) was observed in multiple sarcomas, indicating an enormous potential for PET/CT using 68Ga-radiolabeled inhibitors of FAP (FAPI). Therefore, this retrospective study aimed to evaluate the role of the novel hybrid imaging probe for sarcomas as a first clinical evaluation. Methods A cohort of 15 patients underwent 68Ga-FAPI-PET/CT for staging or restaging. The acquisition of PET scans was performed 60 min after administration of 127 to 308 MBq of the tracer. The uptake of 68Ga-FAPI in malignant tissue as well as in healthy organs was quantified by standardized uptake values SUVmean and SUVmax. Results Excellent tumor-to-background ratios (> 7) could be achieved due to low background activity and high SUVmax in primary tumors (median 7.16), local relapses (median 11.47), and metastases (median 6.29). The highest uptake was found for liposarcomas and high-grade disease (range 18.86–33.61). A high SUVmax (> 10) was observed for clinically more aggressive disease. Conclusion These preliminary findings suggest a high potential for the clinical use of 68Ga-FAPI-PET/CT for patients diagnosed with sarcoma.


2020 ◽  
Vol 152 ◽  
pp. S104
Author(s):  
S. Spohn ◽  
C. Jaegle ◽  
A.S. Bettermann ◽  
S. Kiefer ◽  
C.A. Jilg ◽  
...  

2007 ◽  
Vol 2 (8) ◽  
pp. S363-S364
Author(s):  
Kyung-Min Shin ◽  
Chin A. Yi ◽  
Kyung Soo Lee ◽  
Byung-Tae Kim ◽  
Hojoong Kim ◽  
...  

2009 ◽  
Vol 37 (2) ◽  
pp. 310-318 ◽  
Author(s):  
Fonyuy Nyuyki ◽  
Michail Plotkin ◽  
Reinhold Graf ◽  
Roger Michel ◽  
Ingo Steffen ◽  
...  

2009 ◽  
Vol 92 ◽  
pp. S41
Author(s):  
N. Marmouk ◽  
E. Van Mierlo ◽  
B. Verhoeven ◽  
A. Arens ◽  
M. van de Pol

2020 ◽  
Vol 13 (3) ◽  
pp. 218-227
Author(s):  
Cinzia Crivellaro ◽  
Luca Guerra

Background: Motion artifacts related to the patient’s breathing can be the cause of underestimation of the lesion uptake and can lead to missing of small lung lesions. The respiratory gating (RG) technology has demonstrated a significant increase in image quality. Objective: The aim of this paper was to evaluate the advantages of RG technique on PET/CT performance in lung lesions. The impact of 4D-PET/CT on diagnosis (metabolic characterization), staging and re-staging lung cancer was also assessed, including its application for radiotherapy planning. Finally, new technologies for respiratory motion management were also discussed. Methods: A comprehensive electronic search of the literature was performed by using Medline database (PubMed) searching “PET/CT”, “gated” and “lung”. Original articles, review articles, and editorials published in the last 10 years were selected, included and critically reviewed in order to select relevant articles. Results: Many papers compared Standardized Uptake Value (SUV) in gated and ungated PET studies showing an increase in SUV of gated images, particularly for the small lesions located in medium and lower lung. In addition, other features as Metabolic Tumor Volume (MTV), Total Lesion Glycolysis (TLG) and textural-features presented differences when obtained from gated and ungated PET acquisitions. Besides the increase in quantification, gating techniques can determine an increase in the diagnostic accuracy of PET/CT. Gated PET/CT was evaluated for lung cancer staging, therapy response assessment and for radiation therapy planning. Conclusion: New technologies able to track the motion of organs lesion directly from raw PET data, can reduce or definitively solve problems (i.e.: extended acquisition time, radiation exposure) currently limiting the use of gated PET/CT in clinical routine.


Sign in / Sign up

Export Citation Format

Share Document