Biomechanical Evaluation of Suture Anchor versus Transosseous Tunnel Patellar Tendon Repair Techniques

2018 ◽  
Vol 32 (08) ◽  
pp. 825-832 ◽  
Author(s):  
Seth L. Sherman ◽  
Brandee Black ◽  
Matthew A. Mooberry ◽  
Katie L. Freeman ◽  
Trevor R. Gulbrandsen ◽  
...  

AbstractThe objective of this study is to compare the cyclic loading strength and ultimate failure load in suture anchor repair versus transosseous tunnel repair of patellar tendons using a cadaver model. Twelve cadaveric patella specimens were used (six matched pairs). Dual-energy X-ray absorptiometry (DXA) measurements were performed to ensure equal bone quality among groups. All right knees were assigned to the suture anchor repair group (n = 6), whereas all left knees were assigned to the transosseous bone tunnel group (n = 6). Suture type and repair configuration were equivalent. After the respective procedures were performed, each patella was mounted into a gripping jig. Tensile load was applied at a rate of 1 Hz between magnitudes of 50 and 150 N, 50 and 200 N, 50 and 250 N, and tensile load at a rate of 0.1 mm/s until failure. Failure was defined as a sharp deviation in the linear load versus displacement curve, and failure mode was recorded. DXA measurements demonstrated equivalence of bone quality between the two groups (p > 0.05). During cyclic load testing, there was only a statistically significant difference between the groups with regard to cyclic loading at the 50 to 200 N loading cycle (p = 0.010). There was no statistically significant difference between the groups with regard to ultimate load to failure (p = 0.43). Failure mode within the suture anchor cohort occurred through anchor pullout except for one, which failed through the tendon. All specimens within the transosseous cohort failed through the midsubstance of the tendon except for one, which failed through suture breakage. Suture anchor repair demonstrated a similar biomechanical profile regarding cyclic loading and ultimate load to failure when compared with “gold standard” transosseous tunnel patellar tendon repair with a trend toward less gapping in the suture anchor group. Using suture anchors for repair of the patella tendon has similar biomechanical properties to transpatellar tunnels but may provide other clinical advantages.

2016 ◽  
Vol 9 (2) ◽  
pp. 85-91
Author(s):  
Benjamin Léger-St-Jean ◽  
Jérémie Ménard ◽  
Stéphanie Hinse ◽  
Frédéric Balg ◽  
Dominique M Rouleau

Background To help determine the optimal fixation method for subscapularis tendon repair in arthroplasty, the present study compares single-passage transosseous tape (BT) and modified Mason-Allen #2 suture (MA). Methods Eighteen human cadaveric shoulders were randomized to two repair constructs after arthroplasty preparation. Both techniques included two transosseous passages through the bicipital groove and then through the tendon at the level of the anatomical neck. Construct was tested using a traction machine, measuring cyclic loading and ultimate load to failure. Results The mean age of our specimens was 71 years. No significant difference was observed between the repair techniques in both mean ultimate load and cyclic loading. The mean (SD) ultimate load (UL) for BT was 293 (84) N and 342 (117) N for MA, which was not statistically significant ( p = 0.374). The majority of repairs failed in the tendon. Bone cut-out was observed with the MA but not for the BT repair. No correlation was found between bone density and UL for BT ( r = −0.09) but there was strong correlation for MA ( r = 0.63). Conclusions The MA repair appears to be more dependant on bone mineral density for ultimate load, indicating that braided-tape might be better suited for osteoporotic patients to avoid bone cut-out.


1998 ◽  
Vol 26 (3) ◽  
pp. 428-432 ◽  
Author(s):  
Gregory C. Berlet ◽  
James A. Johnson ◽  
Andrew D. Milne ◽  
Stuart D. Patterson ◽  
Graham J. W. King

Clinical reports suggest that suture anchors can simplify repair of distal biceps tendon avulsions. In this study, fixation strengths of Mitek and Statak suture anchors were compared with strength of reattachment using transosseous suture tunnels in eight cadaveric radii. Cyclic loading and load-to-failure testing were performed: No specimen failed during testing to 50 N for 3600 cycles; however, four of the Mitek anchors and one of the Statak anchors protruded out of the medullary canal. The mean load to failure of the Mitek suture anchor complexes was 220 54 N, that of the Statak suture anchor complexes was 187 64 N, and that of the transosseous sutures was 307 142 N. There was no significant difference in the failure load or mechanism of failure between the Statak and Mitek anchors. Transosseous sutures failed at significantly greater loads on static testing than the suture anchors. Cyclic loading results suggest that the bony fixation achieved using these three techniques should be sufficient to allow immediate passive mobilization of the elbow after surgery. Protrusion of the suture anchors out of the tuberosity during cyclic loading is a concern because of potential development of a gap at the repair site and interference with forearm rotation.


2020 ◽  
Vol 8 (1) ◽  
pp. 232596711989292 ◽  
Author(s):  
Alexander Otto ◽  
Alyssa M. DiCosmo ◽  
Joshua B. Baldino ◽  
Julian Mehl ◽  
Elifho Obopilwe ◽  
...  

Background: Proximal hamstring avulsions are severe tendon injuries and are commonly sports-related. Open and endoscopic techniques as well as different anchor configurations have already been described for proximal hamstring repair. Novel all-suture anchors have been developed to provide decreased bone loss during placement and reduced occupied bone volume when compared with titanium suture anchors. Hypothesis: Complete proximal hamstring avulsions repaired with all-suture anchors will demonstrate equal load to failure and comparable displacement under cyclic loading when compared with titanium suture anchors. Study Design: Controlled laboratory study. Methods: Complete proximal hamstring avulsions were created in 18 paired cadaveric specimens (mean ± SD age, 63.0 ± 10.4 years). Either all-suture anchors or titanium suture anchors were used for repair. Cyclic loading from 10 to 125 N at 1 Hz was performed for 1500 cycles with a material testing machine. Displacement was assessed along anterior and posterior aspects of the tendon repair with optical tracking. Specimens were loaded to failure at a rate of 120 mm/min. Displacement, load to failure, and repair construct stiffness were compared between matched pairs with the Wilcoxon signed-rank test. Correlations were determined by Spearman rho analysis. Results: The all-suture anchors showed significantly higher load-to-failure values when compared with the titanium anchor repairs (799.64 ± 257.1 vs 573.27 ± 89.9 N; P = .008). There was no significant difference in displacement between all-suture anchors and titanium suture anchors at the anterior aspect (6.60 ± 2.2 vs 5.49 ± 1.1 mm; P = .26) or posterior aspect (5.87 ± 2.08 vs 5.23 ± 1.37 mm; P = .678) of the repaired hamstring tendons. Conclusion: All-suture anchors demonstrated similar displacement and superior load to failure when compared with titanium suture anchors. Clinical Relevance: The results of this study suggest that all-suture anchors are an equivalent alternative to titanium suture anchors for proximal hamstring avulsion repair.


2021 ◽  
Vol 9 (1) ◽  
pp. 232596712097439
Author(s):  
Heath P. Gould ◽  
William R. Rate ◽  
Pooyan Abbasi ◽  
Katherine L. Mistretta ◽  
Jason W. Hammond

Background: Adjustable cortical fixation devices have demonstrated utility in orthopaedic applications, such as ankle syndesmosis repair. Purpose: To assess the cyclic gap formation of a quadriceps tendon repair technique using an adjustable cortical fixation device compared with repair with knotless suture anchors and suture tape, a modification of conventional suture anchor repair. Study Design: Controlled laboratory study. Methods: Eight fresh-frozen matched pairs of cadaveric knees were used. Specimens in each pair were randomized to undergo either modified suture anchor repair (control) or adjustable cortical fixation repair. The control repair was performed as previously described. The experimental repair was performed using 2 No. 2 FiberWire sutures placed into the quadriceps tendon in a running locked Krackow configuration and 2 adjustable loop devices passed through transosseous tunnels. The lagging strands of the devices were tensioned to seat the cortical fixation buttons at the inferior patellar pole and then tied to the free Krackow strands at the superior pole to complete the repair. The mean plastic gap (permanent tendon displacement that did not recover with cyclic extension) and mean maximum gap (peak displacement that occurred with cyclic knee flexion and partially recovered with extension) were evaluated during cyclic loading for 500 cycles of full knee extension to 90° of flexion. Results: At all testing intervals, the mean plastic gap was significantly smaller for the cortical fixation group versus the suture anchor group ( P < .02). Similarly, the mean maximum gap was significantly smaller for the cortical fixation specimens at all testing intervals ( P < .01). After cyclic loading, the mean maximum gap was significantly smaller in the cortical fixation group (4.80 ± 1.56 mm) versus the suture anchor group (8.47 ± 1.47 mm; P = < .001). The mean plastic gap was also significantly smaller in the cortical fixation versus the suture anchor group (3.25 ± 1.10 mm vs 6.57 ± 1.62 mm, respectively; P = < .001). Conclusion: Quadriceps tendon repair using an adjustable cortical fixation device demonstrated superior biomechanical properties in cyclic displacement testing compared with repair using the suture anchor technique. Clinical Relevance: These results suggest that an adjustable cortical fixation device is a biomechanically viable alternative for quadriceps tendon repair.


2019 ◽  
Vol 7 (2) ◽  
pp. 232596711882414 ◽  
Author(s):  
Michael B. Gerhardt ◽  
Benjamin S. Assenmacher ◽  
Jorge Chahla

Background: Despite an abundance of literature regarding construct strength for a myriad of anchors and anchor configurations in the shoulder, there remains a paucity of biomechanical studies detailing the efficacy of these implants for proximal hamstring repair. Purpose: To biomechanically evaluate the ultimate failure load and failure mechanism of knotless and knotted anchor configurations for hamstring repair. Study Design: Controlled laboratory study. Methods: A total of 17 cadaveric specimens divided into 3 groups composed of intact hamstring tendons as well as 2 different anchor configurations (all-knotted and all-knotless) underwent first cyclic loading and subsequent maximal loading to failure. This protocol entailed a 10-N preload, followed by 100 cycles incrementally applied from 20 to 200 N at a frequency of 0.5 Hz, and ultimately followed by a load to failure with a loading rate of 33 mm/s. The ultimate failure load and mechanism of failure were recorded for each specimen, as was the maximal displacement of each bone-tendon interface subsequent to maximal loading. Analysis of variance was employed to calculate differences in the maximal load to failure as well as the maximal displacement between the 3 study groups. Holm-Sidak post hoc analysis was applied when necessary. Results: The all-knotless suture anchor construct failed at the highest maximal load of the 3 groups (767.18 ± 93.50 N), including that for the intact tendon group (750.58 ± 172.22 N). There was no statistically significant difference between the all-knotless and intact tendon groups; however, there was a statistically significant difference in load to failure when the all-knotless construct was compared with the all-knotted technique (549.56 ± 20.74 N) ( P = .024). The most common mode of failure in both repair groups was at the suture-tendon interface, whereas the intact tendon group most frequently failed via avulsion of the tendon from its insertion site. Conclusion: Under biomechanical laboratory testing conditions, proximal hamstring repair using all-knotless suture anchors outperformed the all-knotted suture anchor configuration with regard to elongation during cyclic loading and maximal load to failure. Failure in the all-knotted repair group was at the suture-tendon interface in most cases, whereas the all-knotless construct failed most frequently at the musculotendinous junction. Clinical Relevance: No biomechanical studies have clearly identified the optimal anchor configuration to avert proximal hamstring repair failure. Delineating this ideal suture anchor construct and its strength compared with an intact hamstring tendon may alter the current standards for postoperative rehabilitation, which remain extremely conservative and onerous for these patients.


2020 ◽  
Vol 8 (1) ◽  
pp. 232596711989812
Author(s):  
Hong Li ◽  
Hanlin Xu ◽  
Yinghui Hua ◽  
Wenbo Chen ◽  
Hongyun Li ◽  
...  

Background: To date, there are few biomechanical studies comparing the strength between knot repair and knotless repair procedures for anterior talofibular ligament (ATFL) injury. Purpose: To perform a biomechanical comparison of the strength of the arthroscopic ATFL repair technique with knot or knotless suture anchors in a cadaveric model with partial or complete ATFL injuries. Study Design: Controlled laboratory study. Methods: A total of 24 fresh-frozen cadaveric ankles were used. Arthroscopy was used to identify, section, and repair the ATFL on the fibular insertion site. The specimens were then randomly placed into 1 of 4 groups: group A received complete ATFL section and 1–suture anchor repair with knot, group B received complete ATFL section and 1-anchor knotless repair, group C received partial ATFL section and 1–suture anchor repair with knot, and group D received partial ATFL section and 1-anchor knotless repair. After repair, the ATFL tension was measured first with a digitalized tensiometer. Specimens were then mounted on a materials testing system to determine the ultimate load to failure and stiffness. Results: The mean ± SD ligament tension measured during the arthroscopic procedure was 8.6 ± 0.6 N for group A, 9.2 ± 0.5 N for group B, 9.4 ± 1.1 N for group C, and 9.6 ± 0.9 N for group D. No significant difference in tension was detected among groups. In load-to-failure testing, the mean ultimate failure load was 27.9 ± 4.1 N for group A, 26.2 ± 9.3 N for group B, 81.9 ± 26.5 N for group C, and 88.1 ± 41.6 N for group D. The mean ultimate failure loads of the partial repair groups were significantly higher than those of the complete repair groups (C vs A, P = .008; D vs B, P = .002), while there was no significant difference between groups A and B ( P > .05) or between groups C and D ( P > .05). Conclusion: The results of the present study showed that there was no significant difference in biomechanical properties between knot repair and knotless repair techniques. Clinical Relevance: Biomechanically, the results showed that knot suture anchor and knotless suture repair provide similar biomechanical strength for ATFL injury. Unfortunately, these methods in the complete ATFL section models provided less than half the strength and stiffness in the partial ATFL section models at time zero after surgery. As a result, 1–suture anchor repair is not suitable for complete ATFL injury regardless of the repair method.


2011 ◽  
Vol 37 (4) ◽  
pp. 316-322 ◽  
Author(s):  
T. Moriya ◽  
M. C. Larson ◽  
C. Zhao ◽  
K.-N. An ◽  
P. C. Amadio

The purpose of this study was to describe a modification of the Massachusetts General Hospital (MMGH) tendon repair and to compare it with three other suture techniques. Twenty human flexor digitorum profundus (FDP) tendons were randomly assigned to the modified Pennington (MP) suture and the MMGH suture. These were compared to the modified Kessler (MK) and Massachusetts General Hospital (MGH) sutures, using data from a previous study. All tendons were repaired with a similar epitendinous stitch and core sutures of 4-0 FiberWire. There was no significant difference in the normalized gliding resistance within the two-strand or four-strand core repair groups. The MP suture had significantly higher 2 mm gap force and ultimate load to failure than the MK suture. The MMGH suture had significantly higher 2 mm gap force and maximum failure ultimate load than the MGH suture. All repairs failed by knot unravelling.


Author(s):  
Paul Borbas ◽  
Rafael Loucas ◽  
Marios Loucas ◽  
Maximilian Vetter ◽  
Simon Hofstede ◽  
...  

Abstract Introduction Coronal plane fractures of the distal humerus are relatively rare and can be challenging to treat due to their complexity and intra-articular nature. There is no gold standard for surgical management of these complex fractures. The purpose of this study was to compare the biomechanical stability and strength of two different internal fixation techniques for complex coronal plane fractures of the capitellum with posterior comminution. Materials and methods Fourteen fresh frozen, age- and gender-matched cadaveric elbows were 3D-navigated osteotomized simulating a Dubberley type IIB fracture. Specimens were randomized into one of two treatment groups and stabilized with an anterior antiglide plate with additional anteroposterior cannulated headless compression screws (group antiGP + HCS) or a posterolateral distal humerus locking plate with lateral extension (group PLP). Cyclic testing was performed with 75 N over 2000 cycles and ultimately until construct failure. Data were analyzed for displacement, construct stiffness, and ultimate load to failure. Results There was no significant difference in displacement during 2000 cycles (p = 0.291), stiffness (310 vs. 347 N/mm; p = 0.612) or ultimate load to failure (649 ± 351 vs. 887 ± 187 N; p = 0.140) between the two groups. Conclusions Posterolateral distal humerus locking plate achieves equal biomechanical fixation strength as an anterior antiglide plate with additional anteroposterior cannulated headless compression screws for fracture fixation of complex coronal plane fractures of the capitellum. These results support the use of a posterolateral distal humerus locking plate considering the clinical advantages of less invasive surgery and extraarticular metalware. Level of evidence Biomechanical study.


2021 ◽  
Vol 12 ◽  
pp. 215145932199274
Author(s):  
Hyojune Kim ◽  
Myung Jin Shin ◽  
Erica Kholinne ◽  
Janghyeon Seo ◽  
Duckwoo Ahn ◽  
...  

Purpose: This biomechanical study investigates the optimal number of proximal screws for stable fixation of a 2-part proximal humerus fracture model with a locking plate. Methods: Twenty-four proximal humerus fracture models were included in the study. An unstable 2-part fracture was created and fixed by a locking plate. Cyclic loading and load-to-failure tests were used for the following 4 groups based on the number of screws used: 4-screw, 6-screw, 7-screw, and 9-screw groups. Interfragmentary gaps were measured following cyclic loading and compared. Consequently, the load to failure, maximum displacement, stiffness, and mode of failure at failure point were compared. Results: The interfragmentary gaps for the 4-screw, 6-screw, 7-screw, and 9-screw groups were significantly reduced by 0.24 ± 0.09 mm, 0.08 ± 0.06 mm, 0.05 ± 0.01 mm, and 0.03 ± 0.01 mm following 1000 cyclic loading, respectively. The loads to failure were significantly different between the groups with the 7-screw group showing the highest load to failure. The stiffness of the 7-screw group was superior compared with the 6-screw, 9-screw, and 4-screw groups. The maximum displacement before failure showed a significant difference between the comparative groups with the 4-screw group having the lowest value. The 7-screw group had the least structural failure rate (33.3%). Conclusion: At least 7 screws would be optimal for proximal fragment fixation of proximal humerus fractures with medial comminution to minimize secondary varus collapse or fixation failure. Level of Evidence: Basic science study.


2017 ◽  
Vol 2 (4) ◽  
pp. 247301141771543 ◽  
Author(s):  
Robert G. Dekker ◽  
Charles Qin ◽  
Cort Lawton ◽  
Muturi G. Muriuki ◽  
Robert M. Havey ◽  
...  

Background: Soft tissue complications after Achilles tendon repair has led to increased interest in less invasive techniques. Various limited open techniques have gained popularity as an alternative to open operative repair. The purpose of this study was to biomechanically compare an open Krackow and limited open repair for Achilles tendon rupture. We hypothesized that there would be no statistical difference in load to failure, work to failure, and initial linear stiffness. Methods: A simulated Achilles tendon rupture was created 4 cm proximal to its insertion in 18 fresh-frozen cadaveric below-knee lower limbs. Specimens were randomized to open or limited open PARS Achilles Jig System repair. Repairs were loaded to failure at a rate of 25.4 mm/s to reflect loading during normal ankle range of motion. Load to failure, work to failure, and initial linear stiffness were compared between the 2 repair types. Results: The average load to failure (353.8 ± 88.8 N vs 313.3 ± 99.9 N; P = .38) and work to failure (6.4 ± 2.3 J vs 6.3 ± 3.5 J; P = .904) were not statistically different for Krackow and PARS repair, respectively. Mean initial linear stiffness of the Krackow repair (17.8 ± 5.4 N/mm) was significantly greater than PARS repair (11.8 ± 2.5 N/mm) ( P = .011). Conclusion: No significant difference in repair strength was seen, but higher initial linear stiffness for Krackow repair suggests superior resistance to gap formation, which may occur during postoperative rehabilitation. With equal repair strength, but less soft tissue devitalization, the PARS may be a favorable option for patients with risk factors for soft tissue complications.