scholarly journals Secondary Dentin as an Aid in Gender Predilection: A Forensic Study

Author(s):  
Himanshu Singh ◽  
Vedant Patel ◽  
Rahul A. Razdan ◽  
Deepak Jha ◽  
Prachi Nayak ◽  
...  

Abstract Background Forensic odontology deals with age, sex, and race determination of the deceased at crime scenes, disasters, or natural calamities. Studies regarding the role of secondary dentin in age estimation have been documented on a several occasions in the literature but use of secondary dentin in gender predilection has not yet been documented. So, the present study was aimed at using the secondary dentin as a diagnostic tool in gender predilection. Materials and Methods The study included a total of 20 samples (10 males and 10 females). Extracted teeth were collected and placed in 10% neutral buffered formalin solution. The sections were ground on Arkansas stone until the appropriate thickness of the ground sections was achieved. The freshly prepared ground section was mounted on a slide using DPX mounting media. Ground sections were visualized under a microscope and the thickness of secondary dentine was measured using the image analysis software. Results The data were collected and subjected to group statistics. The secondary dentin thickness of all the samples, males and females, was measured. It was observed in our study that the mean thickness of secondary dentin was more in male samples (0.2970) with the standard deviation of 0.01494, as compared with that of females where the mean thickness was found to be 0.1970 with the standard deviation of 0.02058. Conclusion This study has shown that variation in secondary dentin thickness does exist between male and female groups. This criterion can be considered as an aid for gender determination in the future.

2016 ◽  
Vol 56 (12) ◽  
pp. 2060 ◽  
Author(s):  
Serkan Ozkaya ◽  
Wojciech Neja ◽  
Sylwia Krezel-Czopek ◽  
Adam Oler

The objective of this study was to predict bodyweight and estimate body measurements of Limousin cattle using digital image analysis (DIA). Body measurements including body length, wither height, chest depth, and hip height of cattle were determined both manually (by measurements stick) and by using DIA. Body area was determined by using DIA. The images of Limousin cattle were taken while cattle were standing in a squeeze chute by a digital camera and analysed by image analysis software to obtain body measurements of each animal. While comparing the actual and predicted body measurements, the accuracy was determined as 98% for wither height, 97% for hip height, 94% for chest depth and 90.6% for body length. Regression analysis between body area and bodyweight yielded an equation with R2 of 61.5%. The regression equation, which included all body traits, resulted in an R2 value of 88.7%. The results indicated that DIA can be used for accurate prediction of body measurements and bodyweight of Limousin cattle.


Author(s):  
Theresa Schranz ◽  
Jochen Klaus ◽  
Wolfgang Kratzer ◽  
Julian Schmidberger ◽  
Melanie Güthle

Abstract Objectives This study aimed to compare spleen sizes in a hospital and a population sample using ultrasound and define normal values and factors influencing spleen size. Methods Both samples’ spleen sizes (n = 1520) were measured using ultrasound under the same conditions. Blood counts and other laboratory parameters were determined under the same conditions in both samples. Results In the hospital sample (n = 760), the mean spleen size was 114.7 mm, and in the population sample (n = 760), it was 99.1 mm. In both, spleen size in men was significantly higher than in women (p < 0.0001) and influenced by body height, weight, and BMI (body mass index) (p < 0.0001). In the hospital sample, there was a correlation with higher values for ALT (p = 0.0160), AST (p = 0.0394), AP (p = 0.0482), and ferritin (p = 0.0008) and lower values for HDL (p = 0.0091) and thrombocytes (p < 0.0001). In the multivariate analysis, higher values for AP (p = 0.0059) and lower values for hemoglobin (p = 0.0014) and thrombocytes (p = 0.0001) were found. Stratified for sex (men, women), spleen size increased with higher values for ALT (p = 0.0116, p = 0.0113), AST (p = 0.0014, p = 0.0113), and AP (p = 0.0001, p = 0.0012), and with lower values of hemoglobin (p = 0.0057, p = 0.0016), thrombocytes (p < 0.0001, p = 0.0003), and albumin (p = 0.0029, p = 0.0432). In women, there was a discordant correlation with red blood cells (p = 0.0005) and a concordant correlation with GGT (p = 0.0241), and in men discordant correlations with cholesterol (p = 0.0010) and HDL (p = 0.0404). Conclusions The already proven impact of anthropometric data on spleen size was confirmed. The role of laboratory values should be further analyzed.


1993 ◽  
Vol 3 (3) ◽  
pp. 307-314 ◽  
Author(s):  
H. Mittelstaedt ◽  
S. Glasauer

This contribution examines the consequences of two remarkable experiences of subjects in weightlessness, 1) the missing of sensations of trunk tilt and of the respective concomitant reflexes when the head is tilted with respect to the trunk, and 2) the persistence of a perception of “up” and “down,” that is, of the polarity of the subjective vertical (SV) in the absence of, as well as in contradiction to, visual cues. The first disproves that the necessary head-to-trunk coordinate transformation be achieved by adding representations of the respective angles gained by utricles and neck receptors, but corroborates an extant model of cross-multiplication of utricular, saccular, and neck receptor components. The second indicates the existence of force-independent components in the determination of the SV. Although the number of subjects is still small and experimental conditions are not as homogeneous as desired, measurements and/or reports on the ground, in parabolic, and in space flight point to the decisive role of the saccular z-bias, that is, of a difference of the mean resting discharges of saccular units polarized in the rostrad and the caudad (±z-) direction.


2016 ◽  
Vol 12 (3) ◽  
pp. 603-621 ◽  
Author(s):  
NABAMITA DUTTA ◽  
CLAUDIA R. WILLIAMSON

AbstractCan foreign aid help free the press? Aid may boost press freedom by incentivizing government to reduce media regulations and provide financial support for infrastructure. Alternatively, foreign aid may prevent press freedom by expanding the role of the state and promoting government over private enterprises. We contend that the magnitude of foreign aid's influence is conditional on the existence of democratic checks. Using panel data from 1994 to 2010, we find evidence suggesting that aid significantly increases press freedom in democracies but insignificantly relates to press freedom in autocracies. Collectively, the results suggest that a standard deviation increase in aid to a country at the mean level of democracy increases press freedom by approximately a 1/20th standard deviation. Overall, the findings suggest that donors should be cautious as most aid recipients are not democratic and aid leads to only relatively small marginal improvements in press freedom.


1973 ◽  
Vol 56 (5) ◽  
pp. 1164-1172
Author(s):  
Milan Ihnat ◽  
Robert J Westerby ◽  
Israel Hoffman

Abstract The distillation-spectrophotometric method of Hoffman for determining maleic hydrazide has been modified to include a double distillation and was applied to the determination of 1–30 ppm maleic hydrazide residues in tobacco and vegetables. Recoveries of 1–23 μg added maleic hydrazide were independent of weight of maleic hydrazide, but did depend on sample and sample weight. The following recoveries were obtained from 0.5 g sample: pipe tobacco, 84%; commercially dehydrated potato, 83%; cigar tobacco, 81%; dried potato, 76%; fluecured tobacco, 73%; dried carrot, 71%. In the absence of sample, the recovery was 82%. When appropriate standard curves were used, maleic hydrazide levels determined in tobacco samples were essentially independent of sample weight in the range 0.1–3 g. The mean relative standard deviation for a variety of field-treated and fortified tobacco samples containing 1–28 ppm maleic hydrazide was 3%. The precision and sensitivity of this procedure seem to be substantial improvements over official method 29.111–29.117. It is recommended that the present method be subjected to a collaborative study.


2019 ◽  
Vol 33 (04) ◽  
pp. 357-364
Author(s):  
Kelly M. Rogers ◽  
Daniel C. Berman ◽  
Justin W. Griffin ◽  
Kevin F. Bonner

AbstractThe purpose of this study was to assess potential gender differences in size of the lateral and medial trochlea of the male and female knee as well as the variation within gender of potential osteochondral autograft transfer (OAT) donor site area. Two hundred and twelve skeletally mature patients, 106 males and 106 females, who underwent a 3T magnetic resonance imaging of the knee for a variety of indications were utilized for analysis. Exclusion criteria included degenerative arthritis, trochlear dysplasia, and poor image quality. Medial and lateral femoral trochlear cartilage width was obtained using a linear radiologic measurement tool. Widths were measured from a reproducible anatomic location representing the maximal trochlear dimension in a region where donor plugs are commonly harvested. Trochlear width was also plotted as a function of patient height. Statistical analysis was performed using a two-sample t-test. The mean and standard deviation of the lateral trochlear cartilage width (mm) for males and females were 23.38 +/− 2.14 and 20.44 +/− 2.16, respectively (p < 0.00001). The mean and standard deviation of the medial trochlear cartilage width (mm) for males and females were 14.16 +/− 2.17 and 11.78 +/− 2.03, respectively (p < 0.00001). The overall range in trochlear width for both the lateral and medial sides was 22.22 and 19.73 mm for males and females, respectively. A graft measuring 10 mm could represent as little as 34% of the lateral trochlea in males versus as much as 65% in females. Our results indicate that donor OAT plug diameter relative to available trochlear cartilage width will vary significantly both between genders and individual patients. Trochlear width variability and its potential implications on donor site morbidity may be an important consideration when contemplating osteochondral plug harvest for OAT or other indications. The level of evidence is IV.


1974 ◽  
Vol 57 (2) ◽  
pp. 368-372 ◽  
Author(s):  
Milan Ihnat

Abstract A fluorometric method using 2,3-diaminonaphthalene for estimating selenium has been evaluated with regard to its applicability to food samples. Charring of the sample during digestion appeared to result in losses of native and added selenium from some samples, so a modified wet digestion procedure was introduced. Digestion first in nitric acid followed by a mixture of nitric-perchloric-sulfuric acids substantially reduced the incidence of sample charring for a variety of foods. The mean apparent recovery of selenium added as selenite or selenate at 100 and 500 ng levels to 0.1 and 1.0 g corn cereal, skim milk powder, and meat and 0.1 g fish was 101.0%; the actual recovery of the same levels of selenium from standard solutions was 96.6%. For a variety of samples containing 5—750 ng native or added selenium, the standard deviation as 4.7 + 1.95 X 10-2W ng, where W = ng selenium in the sample taken for analysis. The relative standard deviation (RSD) as a function of selenium weight (ng) was 50% (10), 6.7% (100), 4.3% (200), 3.1% (400), 2.7% (600), and 2.5% (800). The detection limit (weight of selenium at which RSD = 50%) was 10 ng at a mean blank level of 25 ng.


1982 ◽  
Vol 65 (1) ◽  
pp. 85-88 ◽  
Author(s):  
Patrick J Casey ◽  
Keevin R Speckman ◽  
Frank J Ebert ◽  
William E Hobbs

Abstract A radioisotope dilution (RID) method for the determination of vitamin B12 is presented. The method combines a standard extraction procedure (AOAC 43.108,12th ed.) with a commercially available RID assay kit. The method was evaluated on a wide range of fortified and unfortified food products. Recovery studies on both groups yielded average recoveries of 98.1 and 95.8%, respectively. Reproducibility data generated from replicate analyses on both groups gave a relative standard deviation of 6.9% for the fortified group and 9.2% for the unfortified group. For the samples studied, the mean vitamin B12 content determined by the RID method was 8.01 μg/100 g vs imean of 7.54 μg/100 g by the AOAC microbiological method; the correlation coefficient was r = 0.983.


1962 ◽  
Vol 29 (1) ◽  
pp. 47-53 ◽  
Author(s):  
J. D. S. Goulden ◽  
P. Sherman

SummaryA rapid spectroturbidimetric method for the determination of the fat content of homogenized ice-cream mixes using a simple filter absorptiometer has been devised. Turbidities are measured at two different wavelengths to allow for changes in the degree of homogenization. The standard deviation of the differences from the values obtained by the Werner-Schmid method was found to be 2·5% of the mean fat content value. The method also enables the mean fat globule diameter to be determined.


Sign in / Sign up

Export Citation Format

Share Document