Numerical and Experimental Assessment of an Improved Design Detail for Partially Grouted Reinforced Masonry Wall Structures

2021 ◽  
Vol 147 (8) ◽  
pp. 04021118
Author(s):  
Andreas A. Koutras ◽  
P. Benson Shing
Materials ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 505 ◽  
Author(s):  
Dariusz Bajno ◽  
Lukasz Bednarz ◽  
Zygmunt Matkowski ◽  
Krzysztof Raszczuk

In order to create and make available the following: Design guidelines, recommendations for energy audits, data for analysis and simulation of the condition of masonry walls susceptible to biological corrosion, deterioration of comfort parameters in rooms, or deterioration of thermal resistance, the article analyzes various types of masonry wall structures occurring in and commonly used in historical buildings over the last 200 years. The summary is a list of results of particular types of masonry walls and their mutual comparison. On this basis, a procedure path has been proposed which is useful for monitoring heat loss, monitoring the moisture content of building partitions, and improving the hygrothermal comfort of rooms. The durability of such constructions has also been estimated and the impact on the condition of the buildings that have been preserved and are still in use today was assessed.


Buildings ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. 103
Author(s):  
Houria Hernoune ◽  
Benchaa Benabed ◽  
Antonios Kanellopoulos ◽  
Alaa Hussein Al-Zuhairi ◽  
Abdelhamid Guettala

Near surface mounted (NSM) carbon fibers reinforced polymer (CFRP) reinforcement is one of the techniques for reinforcing masonry structures and is considered to provide significant advantages. This paper is composed of two parts. The first part presents the experimental study of brick masonry walls reinforced with NSM CFRP strips under combined shear-compression loads. Masonry walls have been tested under vertical compression, with different bed joint orientations 90° and 45° relative to the loading direction. Different reinforcement orientations were used including vertical, horizontal, and a combination of both sides of the wall. The second part of this paper comprises a numerical analysis of unreinforced brick masonry (URM) walls using the detailed micro-modelling approach (DMM) by means of ABAQUS software. In this analysis, the non-linearity behavior of brick and mortar was simulated using the concrete damaged plasticity (CDP) constitutive laws. The results proved that the application of the NSM-CFRP strips on the masonry wall influences significantly strength, ductility, and post-peak behavior, as well as changing the failure modes. The adopted DMM model provides a good interface to predict the post peak behavior and failure mode of unreinforced brick masonry walls.


Materials ◽  
2019 ◽  
Vol 12 (12) ◽  
pp. 1923 ◽  
Author(s):  
Tereza Pavlu ◽  
Kristina Fortova ◽  
Jakub Divis ◽  
Petr Hajek

The main aim of this paper is to carry out the environmentally based enhancement of a concrete mixture containing recycled materials whilst considering natural resource consumption as well as mechanical and thermal property levels. The developed concrete is intended to be used in mortarless masonry wall structures. Ten concrete mixtures with different types and replacement rates of recycled masonry aggregate and recycled expanded polystyrene were prepared, and their mechanical and thermal properties were experimentally investigated. It was found that the use of recycled masonry aggregate led to better thermal properties while maintaining sufficient mechanical properties. On the contrary, the addition of recycled expanded polystyrene did not significantly affect the thermal properties of concrete, but the mechanical properties considerably declined. For this reason, the recycled masonry aggregate is suitable to use as an aggregate for concrete masonry blocks for wall structures.


2011 ◽  
Vol 33 (6) ◽  
pp. 1955-1965 ◽  
Author(s):  
José Fernando Sima ◽  
Pere Roca ◽  
Climent Molins

2020 ◽  
Vol 20 (6) ◽  
pp. 7-13
Author(s):  
Dong-Jin Yoon ◽  
Kwang-Mo Lim ◽  
Joo-Ha Lee

Recently, research focused on preventing the aging of masonry structures, and minimization of damage caused by earthquakes to these structures has gained significant attention. To improve the performance of these structures, an appropriate method is required for their performance evaluation. Generally, the equivalent strut model is employed for the performance evaluation of a masonry wall. However, this method is known to have limitations in implementing reinforced masonry and in reflecting the actual reinforcement effect. Appropriate evaluation techniques should be developed to implement the performance improvement methods developed in the future. Therefore, in this study, analysis methods were developed considering the nonlinear static analysis method for masonry elements. In addition, using these methods, the analysis considering the various reinforced thicknesses and shapes was performed, and the appropriate reinforcement methods were presented for these structures.


2017 ◽  
Vol 747 ◽  
pp. 504-511
Author(s):  
Natalino Gattesco ◽  
Alessandra Gubana ◽  
Massimo Melotto

The use of a GFRP (Glass Fiber Reinforced Polymers) mesh, embedded as a reinforcement in a mortar coating on both wall sides, proved to be effective and reliable in increasing the masonry wall resistance and the plastic deformation capacity.In this study, a NL finite element model, developed to predict the in-plane behaviour of masonry walls strengthened by means of this technique, is refined and used in an extensive parametric study. Numerical results were compared with diagonal compression test data on URM and RM cobblestone masonry samples, showing good agreement. The masonry panel and the mortar coating were modelled as isotropic homogeneous materials with a smeared crack approach, whereas the GFRP reinforcement was modelled as a mesh of truss elements. Properties assigned to materials were derived from experimental tests.The parametric study performed before on some involved mechanical properties, considering a standard range of variation, is now extended to other parameters. Moreover, the combined variation of different properties is considered. The actual contribute of each component (masonry, GFRP mesh, mortar) on some macroscopic parameters (strength and ductility of the specimen) is evaluated.The parametric analysis highlights the important role of the GFRP mesh not only on the peak load increment but also on the post-peak behavior and, in particularly, on the ductility increment of the reinforced masonry panel. These results can address the optimization of the intervention technique and the deliverable of operative guidelines for practitioners.


Sign in / Sign up

Export Citation Format

Share Document