Seismic Characteristics of Concentrated Linked Beam Frame System

2022 ◽  
Vol 148 (3) ◽  
Author(s):  
Sanaz Ahlehagh ◽  
Seyed Rasoul Mirghaderi
2018 ◽  
Vol 203 ◽  
pp. 06014
Author(s):  
Zafarullah Nizamani ◽  
Seah Kay Seng ◽  
Akihiko Nakayama ◽  
Mohamad Shariff Bin Omar Khan ◽  
Haider Bilal

Most of the residential buildings in Malaysia are not designed to withstand the seismic forces, while the high-rise buildings. However, since the Sumatra 2004 earthquake, there had been increasing concerns about the structure vulnerability in our country to earthquakes. Several recent studies had also revealed that Malaysia had the possibility to be influenced by both local and far field earthquakes. This study is conducted to analyze the vulnerability of a high rise building to local and far field earthquakes using Scia Engineer. Modal Response Spectrum method of Scia Engineer is used. The model is a 12 story hotel building from Ipoh, Perak. The designing code is the Eurocode with Malaysia Annex. Different Peak Ground Accelerations (PGA) that represents the local and far field earthquakes is acted on the model to obtain the seismic performance. The deformation of the building by the seismic combinations is compared to the ASCE-7 design to evaluate the vulnerability. Research of seismic performance of the flat slab system is also conducted along with beam frame system. The result shows that the building is in a safe condition in terms of deformation and the seismic performance of the flat slab system is advantageous.


2007 ◽  
Vol 35 (1) ◽  
pp. 1-12 ◽  
Author(s):  
Yulianto P. Prihatmaji

Javanese traditional house is located on earthquake zone 3 (midlle level), it spread from Banyuwangi (on East direction) until Cirebon (on West direction). Refer to form and construction system, the Joglo type house look a master piece of Javanese traditional house. It has impression of weight construction with rong-rongan structure (core in frame system from umpak-soko guru-tumpang sari) as vertical structure system. When earthquake come, wood structure of-rongan of Joglo house as a core structure or core in frame, it's a restrain to lateral force and depending on flexibility, brakebility, stability, elasticity and hiperstaticity of material and construction. The foundation system has hinge character or roll, connection system of tongue and gully configuration of secondary column (soko emper) and main column (soko guru), rigidity of main column (soko guru) from multy beam frame (tumpangsari/brunjung) are unity as earthquake responsive building. The test result of structure model of rong-rongan by vibration of earthquake force from horizontal slip table, is showed application of load system on Javanese traditional house support to stability. It has require on high frequency and acceleration low to high. Test on a vibration with low frequency and acceleration low to high, the load system make more deformation to model. The result of research is showed the structure of traditional Javanese house is safe on earthquake zone 3 (if base founfation maked clamp system). Abstract in Bahasa Indonesia : Rumah tradisional Jawa terletak di daerah gempa III (gempa sedang), terhampar dari Banyuwangi sampai Cirebon. Rumah tradisional Jawa berwujud Joglo secara bentuk dan konstruksi dianggap sebagai master piece rumah tradisional Jawa, yang terkesan berat dengan struktur rong-rongan (umpak-soko guru-tumpang sari) sebagai penahan beban lateral. Apabila terjadi gempa struktur kayu rong-rongan rumah Joglo dipandang sebagai struktur inti (core in frame) yang akan menahan gaya lateral, didukung oleh fleksibilitas, redaman, stabilitas, elastisitas, daktilitas, kehiperstatisan kayu dan konstruksi. Sistem tumpuan yang bersifat sendi dan atau rol, sistem sambungan lidah alur, konfigurasi soko-soko emper terhadap soko guru dan kekakuan soko guru oleh tumpang sari/brunjung dipandang sebagai kesatuan sistem earthquake responsive building. Hasil pengujian model struktur rong-rongan terhadap getaran gaya gempa dengan horizontal slip table, menunjukkan bahwa sistem pembebanan yang diterapkan di rumah Joglo menyumbang kestabilan, pada gempa frekuensi tinggi dan akselerasi rendah-tinggi. Pada getaran gaya gempa berfrekuensi rendah dan akselerasi rendah-tinggi, sistem pembebanan membuat model lebih banyak mengalami deformasi. Hasil penelitian menunjukkan bahwa, struktur rumah Joglo aman untuk daerah zona gempa 3 (apabila sistem tumpuan dibuat jepit). Kata kunci: struktur joglo, konstruksi rong-rongan, sistem sambungan dan tumpuan, gaya gempa.


MedPharmRes ◽  
2019 ◽  
Vol 2 (4) ◽  
pp. 15-19
Author(s):  
Son Nguyen ◽  
Son Vi ◽  
Hoat Luu ◽  
Toan Do

There are cases when symptoms are available but no abnormal stenosis is found in MRI and vice versa. Axial-loaded MRI has been shown that it can demonstrate more accurately the real status of spinal canal stenosis than conventional MRI. This is the first time we applied a new system that we have recreated from the original loading frame system in order to fit with the demands of Vietnamese people. Sixty-two patients were selected from Phu Tho Hospital in Phu Tho Province, Vietnam, who fulfilled the inclusion criteria. The Anterior-posterior diameter (APD), Dura Cross-sectional Area (DSCA) in conventional MRI and axial loaded MRI, and changes in APD and DCSA were determined at the single most constricted intervertebral level. The APD and DCSA in axial loaded MRI had very good significant correlations with VAS for back pain (rs=0.83, 0.79), leg pain (rs=0.69, 0.57) and JOA score (rs=0.70, 0.65). APD and DCSA in axial loaded MRI significantly correlated with the severity of symptoms. Our axial loading MRI provides more valuable information than the conventional MRI for assessing patients with LSCS.


PCI Journal ◽  
1972 ◽  
Vol 17 (6) ◽  
pp. 26-36
Author(s):  
Earle A. Butts
Keyword(s):  

1995 ◽  
Author(s):  
Theron J. Bennett ◽  
Keith L. McLaughlin ◽  
Margaret E. Marshall ◽  
Brian W. Barker ◽  
John R. Murphy

Sign in / Sign up

Export Citation Format

Share Document