Singularities in three-dimensional affine control systems with scalar control

2007 ◽  
Vol 62 (4) ◽  
pp. 821-822
Author(s):  
Aleksei O Remizov
1988 ◽  
Vol 53 (6) ◽  
pp. 1107-1133 ◽  
Author(s):  
Bernard Fleet

A review of electrochemical reactor systems for the recovery of metals and for pollution control applications is presented. The major engineering factors which influence the design of reactors are evaluated and the key features of two-dimensional and three-dimensional reactor designs are discussed. Some examples of the application of electrochemical reactors to the recovery of metals from dilute solutions are given in the form of case studies, covering both pollution control and resource recovery processes. Finally a comparison is made of the relative technical and economic merits of electrochemical recovery pollution control systems and conventional chemical waste treatment routes.


2018 ◽  
Vol 211 ◽  
pp. 04007
Author(s):  
Alexander Petrov ◽  
Semyon Shkundin

The establishment of dispatching and automatic control systems for mine ventilation is impossible without the availability of perfect air flow rate sensors. Existing anemometers (tachometer, heat) do not meet these requirements. The error of average in cross section velocity measurements with such sensors reaches 15-20, sometimes 30%. The reason - the speed measured at one point is interpreted as the average over the cross section. The reliability of the sensors is small, because they are exposed to the damaging effect of a dusty atmosphere. Stationary installed anemometers clutter cross section, which is not always allowed. Fermat’s variational principle is used for derivation of the formula for the time of propagation of a sonic signal between two set points A and B in a steady three-dimensional flow of a fluid or gas. It is shown that the fluid flow changes the time of signal reception by a value proportional to the flow rate independently of the velocity profile. The time difference in the reception of the signals from point B to point A and vice versa is proportional with a high accuracy to the flow rate. It is shown that the relative error of the formula does not exceed the square of the largest Mach number. This makes it possible to measure the flow rate of a fluid or gas with an arbitrary steady subsonic velocity field


2017 ◽  
Vol 14 (09) ◽  
pp. 1750126
Author(s):  
A. Kara Hansen ◽  
S. Selcuk Sutlu

In this work, we study minimal realization problem for an affine control system [Formula: see text] on a connected Lie group [Formula: see text]. We construct a minimal realization by using a canonical projection and by characterizing indistinguishable points of the system.


Sign in / Sign up

Export Citation Format

Share Document