Activation and Inactivation of Phosphoenolpyruvate Carboxylase in Leaf Extracts From C4 Species

1978 ◽  
Vol 5 (5) ◽  
pp. 571 ◽  
Author(s):  
MD Hatch ◽  
IR Oliver

The stability of phosphoenolpyruvate carboxylase (EC 4.1.1.31) was examined following extraction of the enzyme from leaves of several C4 plants. Extracts were rapidly processed on small Sephadex G-25 columns to free protein of small-molecular-weight compounds. With most of the species examined, activity was rapidly lost at both 0 and 25°C when the pH was about 7.8 or higher. Addition of bovine serum albumin to extracts incubated at 25°C and pH 8.2 not only prevented inactivation with several species, but resulted in a substantial increase in activity. The addition of dithiothreitol plus Mg2+ to extracts from some of these species reduced or prevented inactivation. With extracts maintained at 0°C, addition of either bovine serum albumin or dithiothreitol was effective only in reducing the rate of inactivation in extracts. Phosphoenolpyruvate carboxylase activity remained stable, or increased substantially, when extracts buffered between pH 7.4 and 6.9 were incubated at either 0 or 25°C. Activation was usually complete within an hour and was often significantly greater at 25°C or when bovine serum albumin was added. The activity of partially purified phosphoenolpyruvate carboxylase from Zea mays was similarly affected by pH, temperature, and bovine serum albumin. The present studies raise doubts about the accuracy of phosphoenolpyruvate carboxylase determinations made during the course of some previous studies on C4 species. Reliable procedures for the determination of phosphoenolpyruvate carboxylase activity in C4 plant extracts are described. Possible physiological implications of the results are considered.

2020 ◽  
Vol 106 ◽  
pp. 105892 ◽  
Author(s):  
Xuanting Liu ◽  
Jingbo Liu ◽  
Wenqi Zhang ◽  
Robin Pearce ◽  
Meiru Chen ◽  
...  

2014 ◽  
Vol 68 (2) ◽  
pp. 207-212 ◽  
Author(s):  
Nemanja Trisovic ◽  
Bojan Bozic ◽  
Slobodan Petrovic ◽  
Svetlana Tadic ◽  
Milka Avramov-Ivic

The anodic behaviour of carbamazepine (CBZ), an anticonvulsant drug, has been studied on gold electrode in 0.1 mol dm-3 phosphate buffer of pH 7.0 by using cyclic voltammetry. It has been found that the value of the oxidative current of pure CBZ at +0.90 V is a linear function of the concentration in a range from 1.0?10-7 to 1.0?10?4 mol dm?3. The detection of CBZ in the concentration of 1.0?10-8 mol dm-3 is among the lowest that have been reported for this drug using voltammetric techniques. CBZ as a content of tablet Galepsine? has been quantitatively determined. It has also been demonstrated that the modification of gold electrode with bovine serum albumin (BSA) results in a decrease of the oxidative peak current due to the binding of the drug to BSA.


1995 ◽  
Vol 75 (4) ◽  
pp. 525-529 ◽  
Author(s):  
R. P. Del Vecchio ◽  
W. D. Sutherland ◽  
M. L. Connor

The purpose of this project was to develop a valid quantitative enzymeimmunoassay (EIA) for progesterone in blood plasma of cattle, pigs and sheep. Rabbit anti-progesterone, mouse monoclonal anti-rabbit IgG, authentic progesterone, and acetylcholine esterase bound covalently to progesterone were the principal reagents used to develop the EIA. Ninety-six well microliter plates were coated with mouse monoclonal anti-rabbit IgG and saturated with bovine serum albumin before use. Rabbit anti-progesterone was diluted to a working dilution of 1:2.0 × 106. Standard curves were linear and ranged from 1.56 to 400 pg of progesterone per well which allowed for the measurement of 0.03125 to 8.0 ng mL−1. Assay sensitivity averaged 1.56 pg well−1. Progesterone was extracted from plasma samples with petroleum ether. Plasma samples (n = 3 or 4 from each species) with unknown amounts of progesterone that were extracted and serially diluted with EIA buffer did not deviate from parallelism with progesterone standard curves in buffer. The correlation between EIA and radioimmunoassay (RIA) measurements of progesterone in the same plasma samples was high (P < 0.0001) for all three species (r = 0.96 for bovine; r = 0.96 for porcine; r = 0.94 for ovine). The regression of EIA data on RIA data produced the following equations:[Formula: see text]The intra- and inter-assay coefficients of variation were 5.4 and 10.6% for bovine, 5.8 and 11.0% for porcine and, 6.1 and 12.3% for ovine, respectively. These data show that this EIA is a valid and reliable memod for quantitating progesterone in extracts of bovine, porcine and ovine plasma. Key words: Enzymeimmunoassay, progesterone, plasma, bovine, porcine, ovine


2020 ◽  
Vol 242 ◽  
pp. 122493 ◽  
Author(s):  
Md Abrar Siddiquee ◽  
Mehraj ud din Parray ◽  
Syed Hassan Mehdi ◽  
Khalid Ahmed Alzahrani ◽  
Abdulmohsen Ali Alshehri ◽  
...  

2011 ◽  
Vol 59 (11) ◽  
pp. 6292-6298 ◽  
Author(s):  
Ru Fang ◽  
Ruifang Hao ◽  
Xia Wu ◽  
Qi Li ◽  
Xiaojing Leng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document