STRESS TESTING OF VALSARTAN. DEVELOPMENT AND VALIDATION OF A HIGH PERFORMANCE LIQUID CHROMATOGRAPHY STABILITY-INDICATING ASSAY

2012 ◽  
Vol 35 (8) ◽  
pp. 1053-1069 ◽  
Author(s):  
Romina M. Bianchini ◽  
Patricia M. Castellano ◽  
Teodoro S. Kaufman
Author(s):  
AWDHUT PIMPALE ◽  
RAJENDRA KAKDE

Objective: The present work was focused on the development and validation of the reversed-phase high-performance liquid chromatography (RP-HPLC) method, which is simple, rapid, precise, accurate, sensitive, economical, and stability-indicating for the quantification of rosuvastatin calcium in bulk and tablet formulation. Methods: The separation was attained on reversed-phase Princeton (C18) column with dimensions (250 mm × 4.6 mm, 5μ) employing buffer, which is a mixture of water (pH 3.0, adjusted with orthophosphoric acid) and methanol in the ratio (20:80) v/v as mobile phase, at flow rate 1.0 ml/min. and detection was carried out at wavelength 240 nm. The retention time under the optimized condition of rosuvastatin calcium was found to be 2.844 min. Results: The linearity of the method was demonstrated in the concentration range of 6-16 µg/ml for rosuvastatin calcium with a correlation coefficient (r2) of 0.9999. The percentage relative standard deviation was ˂2% and percentage recovery was found to be 100.12-101.37% for rosuvastatin calcium. The assay of marketed tablet formulations was found to be 98.99%. Conclusion: The developed RP-HPLC technique was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical and will be used for regular quality control of rosuvastatin calcium in bulk and tablet formulations.


Author(s):  
AWDHUT PIMPALE ◽  
RAJENDRA KAKDE

Objective: The present work was focused on the development and validation of reversed-phase high-performance liquid chromatography (RP-HPLC) method which is simple, rapid, precise, accurate, sensitive, economical, and stability-indicating for the quantification of rosuvastatin (RSV) calcium and clopidogrel bisulfate (CLO) in bulk and tablet formulation. Methods: The separation was attained on RP Princeton (C18) column with dimensions (250 mm × 4.6 mm, 5 μ) employing buffer which is a mixture of water (pH 3.0, adjusted with orthophosphoric acid), and methanol in the ratio (20:80) v/v as mobile phase, at flow rate 1.0 ml/min and detection was carried out at wavelength 240 nm. The retention time under the optimized condition of RSV calcium and CLO was found to be 2.844 min and 4.388 min, respectively. Results: The linearity of the method was demonstrated in the concentration range of 6–16 µg/ml and 45–120 µg/ml for RSV calcium and CLO with a correlation coefficient (r2) of 0.9999 and 0.9996, respectively. The percentage relative standard deviation was ˂2% and percentage recovery was found to be 100.12–101.37% and 99.72–101.09% for RSV calcium and CLO, respectively. Assay of marketed tablet formulation was found to be 98.99% and 99.92%, respectively. Conclusion: The developed RP-HPLC method was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical and could be used for regular quality control of RSV calcium and CLO in bulk and tablet formulations.


Author(s):  
SAILAJA B ◽  
SRAVANA KUMARI K

Objective: The present work was focused on the development and validation of reverse-phase high-performance liquid chromatography (RP-HPLC) method which is simple, rapid, precise, accurate, sensitive, economical, and stability indicating for the quantitation of rosuvastatin calcium in bulk and tablet formulation. Methods: The separation was attained on Waters Symmetry C18 column with dimensions 150×4.6 mm, 5 mm particle size employing 0.1% orthophosphoric acid buffer:acetonitrile in the ratio of 55:45% v/v as mobile phase, which was pumped at a rate of 1.0 ml/min and detected at a wavelength of 241 nm. Results: The linearity of the method was demonstrated in the concentration range of 2–12 μg/ml for rosuvastatin calcium with a correlation coefficient (r2) of 0.999, percentage drug recovery was found to be 100.22–101.16%, and percentage relative standard deviation <2. Limit of detection and limit of quantitation values were found to be 0.013 μg/ml and 0.042 μg/ml, respectively, and assay of marketed tablet formulation was found to be 99.76%. Conclusion: The developed RP-HPLC method was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical and could be used for regular quality control of rosuvastatin calcium in bulk and tablet formulation.


Author(s):  
DEVYANI M. RODE ◽  
NUTAN N. RAO

High-performance liquid chromatography is one of the fastest, safest and precise technology used for determination and separation of pharmaceutical drugs, impurities and biological samples. High-performance liquid chromatography is versatile and it takes less time for quantification of drugs as compared to old liquid chromatography techniques. This article reviews stability indicating HPLC method developed and validated for acidic drugs and their degradation studies.