Application of Smart Dampers for Prevention of Seismic Pounding in Isolated Structures Subjected to Near-fault Earthquakes

Author(s):  
Arash Rayegani ◽  
Gholamreza Nouri
2015 ◽  
Vol 2015 ◽  
pp. 1-17 ◽  
Author(s):  
Dahai Zhao ◽  
Yongxing Li

This paper proposes a new fuzzy logic controller, which is designed for seismic protection of base-isolated structures utilizing piezoelectric friction damper against near-fault earthquakes for different ground sites. According to the elastic design spectrum that Eurocode 8 recommends, one 5% damped elastic design spectrum for Chi-Chi earthquake is proposed to generate artificial earthquakes of different ground sites. The proposed controller employs a hierarchic fuzzy control algorithm, in which a supervisory fuzzy controller governs a sublevel fuzzy controller by altering its input normalization factors according to current level of ground motion. In order to simultaneously reduce the base displacement and superstructure responses of the base-isolated structure during seismic excitations, genetic algorithm is employed to optimize the supervisory fuzzy controller and the preload of piezoelectric friction damper. The efficiency of the proposed controller is also compared with passive controller and a linear quadratic Gauss optimal controller. Numerical results show that the proposed fuzzy logic controller has favorable performance in mitigating the responses of the base-isolated structure.


2013 ◽  
Author(s):  
Seyed Kazem Sadat Shokouhi ◽  
Azam Dolatshah ◽  
Hamid Reza Vosoughifar ◽  
Yousef Rahnavard ◽  
Bijan Dowlatshahi

2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Dewen Liu ◽  
Yafei Zhang ◽  
Sitong Fang ◽  
Yang Liu

For vertical isolated structures with excessive vertical eccentricity for mass and vertical stiffness, horizontal-vertical-rocking response needs to be better understood for vertical isolated structures located in near-fault areas, where long-period velocity pulse can be produced. In this study, a seismic isolation system including quasizero stiffness (QZS) and vertical damper (VD) is used to control near-fault (NF) vertical earthquakes. The responses of horizontal-vertical-rocking coupling base-isolated structure including quasizero stiffness (QZS) and vertical damper (VD) subjected to NF horizontal and vertical ground motions are investigated. Nonlinear dynamic analyses are conducted to study the effects of essential parameters such as isolation system eccentricity, static equilibrium position, vertical isolation period, and vertical damping ratio on seismic responses of vertical isolated structure. It is found that increasing vertical period and damping ratio causes the vertical isolated structures to behave well in reducing rocking responses of structure. The effect of horizontal-vertical-rocking coupling on vertical seismic isolation efficiency is insignificant. The vertical seismic isolation remains effective as compared to the system supported on rubber bearings. The vertical damping can significantly control the vertical displacement and rocking moment.


2020 ◽  
Vol 11 (1) ◽  
pp. 82
Author(s):  
Fabio Mazza ◽  
Mirko Mazza

Elastomeric bearings are commonly used in base-isolation systems to protect the structures from earthquake damages. Their design is usually developed by using nonlinear models where only the effects of shear and compressive loads are considered, but uncertainties still remain about consequences of the tensile loads produced by severe earthquakes like the near-fault ones. The present work aims to highlight the relapses of tension on the response of bearings and superstructure. To this end, three-, seven- and ten-storey r.c. framed buildings are designed in line with the current Italian seismic code, with a base-isolation system constituted of High-Damping-Rubber Bearings (HDRBs) designed for three values of the ratio between the vertical and horizontal stiffnesses. Experimental and analytical results available in literature are used to propose a unified nonlinear model of the HDRBs, including cavitation and post-cavitation of the elastomer. Nonlinear incremental dynamic analyses of the test structures are carried out using a homemade computer code, where other models of HDRBs considering only some nonlinear phenomena are implemented. Near-fault earthquakes with comparable horizontal and vertical components, prevailing horizontal component and prevailing vertical component are considered as seismic input. Numerical results highlight that a precautionary estimation of response parameters of the HDRBs is attained referring to the proposed model, while its effects on the nonlinear response of the superstructure are less conservative.


2021 ◽  
Vol 11 (3) ◽  
pp. 1290
Author(s):  
Santiago Mota-Páez ◽  
David Escolano-Margarit ◽  
Amadeo Benavent-Climent

Reinforced concrete (RC) frame structures with open first stories and masonry infill walls at the upper stories are very common in seismic areas. Under strong earthquakes, most of the energy dissipation demand imposed by the earthquake concentrates in the first story, and this eventually leads the building to collapse. A very efficient and cost-effective solution for the seismic upgrading of this type of structure consists of installing hysteretic dampers in the first story. This paper investigates the response of RC soft-story frames retrofitted with hysteretic dampers subjected to near-fault ground motions in terms of maximum displacements and lateral seismic forces and compares them with those obtained by far-field earthquakes. It is found that for similar levels of total seismic input energy, the maximum displacements in the first story caused by near-fault earthquakes are about 1.3 times larger than those under far-field earthquakes, while the maximum inter-story drift in the upper stories and the distribution and values of the lateral forces are scarcely affected. It is concluded that the maximum displacements can be easily predicted from the energy balance of the structure by using appropriate values for the parameter that reflects the influence of the impulsivity of the ground motion: the so-called equivalent number of cycles.


2018 ◽  
Vol 177 ◽  
pp. 579-597 ◽  
Author(s):  
Cheng Fang ◽  
Qiuming Zhong ◽  
Wei Wang ◽  
Shuling Hu ◽  
Canxing Qiu

2011 ◽  
Vol 90-93 ◽  
pp. 940-945
Author(s):  
Wen Jun Gao ◽  
Guang Wu Tang ◽  
Yi Da Kong

A typical reinforced concrete rib arch bridge was chosen to investigate its nonlinear response to near-fault ground motions recorded in 2008 Wenchuan earthquake. Results showed that significant seismic damage may occur, maximum demands were higher for near-fault records having forward directive than far-fault motions, and the rotational capacity of rib plastic hinge is not enough for the large compression force of arch rib. While backward-directivity motions, typically do not exhibit pulse-type motions, only have medium seismic damage to the arch bridge.


Sign in / Sign up

Export Citation Format

Share Document