The Cryogenic Refractive Indices of S‐FTM16, a Unique Optical Glass for Near‐Infrared Instruments

2004 ◽  
Vol 116 (823) ◽  
pp. 833-841 ◽  
Author(s):  
Warren R. Brown ◽  
Harland W. Epps ◽  
Daniel G. Fabricant
NIR news ◽  
2019 ◽  
Vol 30 (5-6) ◽  
pp. 35-38
Author(s):  
Verena Wiedemair ◽  
Christian Wolfgang Huck

The use of ever smaller near-infrared instruments is becoming more and more prevalent, since they are cheaper, more versatile and often advertised as high-performance spectrometer. The last claim is rarely verified by independent researchers, which is why the presented work evaluates the performance of three hand-held spectrometers in comparison to a benchtop instrument. Seventy-seven samples comprising buckwheat, millet and oat were investigated for their total antioxidant capacity using Folin–Ciocalteu and near-infrared spectroscopy. Partial least squares regression models were established using cross- and test set validation. Results showed that all instruments were able to predict total antioxidant capacity to some extent. The coefficients of determinations ranged from 0.823 to 0.951 for cross-validated and from 0.849 to 0.952 for test set validated models. Errors for cross-validated models ranged from 1.11 to 2.08 mgGAE/g and for test set validated models from 1.02 to 1.86 mgGAE/g.


1998 ◽  
Vol 6 (A) ◽  
pp. A163-A170 ◽  
Author(s):  
B. Barabás

The testing and adjusting procedure of near infrared (NIR) spectrophotometers is based on the measurement of some standards and, if necessary, on the adjustment of the constants in the calibration equation. For this work some use few standards, whereas others use 20 or more. This work was aimed to determine the range of error compensation and the minimum number of standards required. The experiments were applied to wheat protein measurement using two scanning spectrophotometers. The errors in the NIR measurements were characterised as bias, skew, error derived from skew ( Eskew) and standard error of difference corrected for bias and skew ( SEDc) parameters and supposed that errors derived from the change in the wavelength or reflectance of the instrument. The confidence intervals of bias and skew, derived from duplicate measurements of various numbers of wheat standards, were used to determine the minimum number of standards required. The range of error compensation was defined with those bias values, where SEDc was smaller, than an acceptable limit. The range of compensation corresponded to a bias value of ± 8 g kg−1 for wheat protein measurements. The detection of error of measurements required 4 wheat standards. The elimination of errors of bias and skew required 9 standards within the above limits. The developed procedure was tested in case of real instrument error. Diminishing a bias from 5.2 g kg−1 to 0.7 g kg−1 and the root mean square difference ( RMSD) to an acceptable level required the use of 9 standards, similar to the model experiment. The simplicity and rapidity (about 10 min) of the procedure enabled the routine test of NIR instruments. The range of error compensation and the number of standards referred to wheat protein. The simple modelling procedure proved also suitable for the determination of these values for other components and under other measuring conditions.


1993 ◽  
Vol 316 ◽  
Author(s):  
BERTILO E. KEMPF

ABSTRACTTitanium metal is sputtered by ion beams using a Kaufman-type ion source with carbondioxide as working gas. Deposition takes place on watercooled substrates of silicon and InP. The films obtained are amorphous; they adhere excellently. SEM-pictures reveal a featureless dense fracture and a smooth surface. Despite a carbon content of 9 at % the films are highly transparent in the visible and near infrared wavelength range. Refractive indices center around 2.15 at values typically found for amorphous TiO2. The electrical properties are characterized by dielectric constant of ε = 26 ± 3, leakage current densities at breakdown of jL = 3.65 . 10-3 A/cm2 and breakdown fields EB > 1 MeV/cm.


ISRN Optics ◽  
2012 ◽  
Vol 2012 ◽  
pp. 1-4
Author(s):  
H. Kiriyama ◽  
H. Sasao ◽  
A. Sugiyama ◽  
K. Ertel

We report on the design of a compact grism-pair stretcher for a near-infrared noncollinear optical parametric chirped-pulse amplification (OPCPA) system. The grisms are produced by bonding a grating to a prism using a resin. The stretcher is capable of controlling a bandwidth of over 300 nm, which is suitable for parametric amplification of few-cycle pulses. After amplification, pulses can be compressed by the dispersion of optical glass, and the residual group-delay can be compensated with an acousto-optic programmable dispersive filter (AOPDF).


2020 ◽  
Vol 88 ◽  
pp. 103427
Author(s):  
Nieves Núñez-Sánchez ◽  
Gabriele Acuti ◽  
Raffaella Branciari ◽  
David Ranucci ◽  
Naceur Mohamed Haouet ◽  
...  

2007 ◽  
Vol 15 (6) ◽  
pp. 3342 ◽  
Author(s):  
Douglas H. Werner ◽  
Do-Hoon Kwon ◽  
Iam-Choon Khoo ◽  
Alexander V. Kildishev ◽  
Vladimir M. Shalaev