High-Frequency Guided Wave Scattering by a Partly Through-Thickness Hole Based on 3D Theory

2015 ◽  
Vol 32 (8) ◽  
pp. 084301
Author(s):  
Hai-Yan Zhang ◽  
Jian Xu ◽  
Shi-Wei Ma

2006 ◽  
Vol 321-323 ◽  
pp. 968-971
Author(s):  
Won Su Park ◽  
Sang Woo Choi ◽  
Joon Hyun Lee ◽  
Kyeong Cheol Seo ◽  
Joon Hyung Byun

For improving quality of a carbon fiber reinforced composite material (CFRP) by preventing defects such as delamination and void, it should be inspected in fabrication process. Novel non-contacting evaluation technique is required because the transducer should be contacted on the CFRP in conventional ultrasonic technique during the non-destructive evaluation and these conventional contact techniques can not be applied in a novel fiber placement system. For the non-destructive evaluation of delamination in CFRP, various methods for the generation and reception of laser-generated ultrasound are applied using piezoelectric transducer, air-coupled transducer, wavelet transform technique etc. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Air-coupled transducer was tried to be adopted in reception of laser-generated guided wave generated by using linear slit array in order to generate high frequency guided wave with a frequency of 1.1 MHz. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer and linear slit array. Transmitted laser-generated ultrasonic wave was received on back-wall and its frequency was analyzed to establish inspecting technique to detect delamination by non-contact ultrasonic method. In a frequency spectrum analysis, intensity ratio of low frequency and center frequency was approvable parameter to detect delamination.



2013 ◽  
Vol 330 ◽  
pp. 504-509
Author(s):  
Yang Zheng ◽  
Jin Jie Zhou ◽  
Hui Zheng

Although many imaging algorithms such as ellipse and hyperbola algorithm can roughly locate defects in large plate-like structures with sparse guided wave arrays, quantitative characterization of them is still a challenging problem, especially for those small defects known as subwavelength defects. Scattering signals of defects contain abundant information so that can be used to evaluate defects. A defects recognition method using the S-matrix (scattering matrix) was presented. S-matrices of hole and crack with S0 mode incident were experimentally measured. The results show that defects can be recognized from the morphology of 2D S-matrix chart. This method has great potential to achieve more specific parameters of small defects with sparse guided wave arrays.



1985 ◽  
Vol 21 (1) ◽  
pp. 18-21 ◽  
Author(s):  
J. Donnelly ◽  
N. DeMeo ◽  
G. Ferrante ◽  
K. Nichols
Keyword(s):  


Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 860
Author(s):  
Mikhail V. Golub ◽  
Alisa N. Shpak ◽  
Inka Mueller ◽  
Sergey I. Fomenko ◽  
Claus-Peter Fritzen

Since stringers are often applied in engineering constructions to improve thin-walled structures’ strength, methods for damage detection at the joints between the stringer and the thin-walled structure are necessary. A 2D mathematical model was employed to simulate Lamb wave excitation and sensing via rectangular piezoelectric-wafer active transducers mounted on the surface of an elastic plate with rectangular surface-bonded obstacles (stiffeners) with interface defects. The results of a 2D simulation using the finite element method and the semi-analytical hybrid approach were validated experimentally using laser Doppler vibrometry for fully bonded and semi-debonded rectangular obstacles. A numerical analysis of fundamental Lamb wave scattering via rectangular stiffeners in different bonding states is presented. Two kinds of interfacial defects between the stiffener and the plate are considered: the partial degradation of the adhesive at the interface and an open crack. Damage indices calculated using the data obtained from a sensor are analyzed numerically. The choice of an input impulse function applied at the piezoelectric actuator is discussed from the perspective of the development of guided-wave-based structural health monitoring techniques for damage detection.





2017 ◽  
Vol 59 (7) ◽  
pp. 383-388
Author(s):  
Yu Zhang ◽  
Shen Wang ◽  
Qing Wang ◽  
Songling Huang ◽  
Wei Zhao


2021 ◽  
Author(s):  
◽  
Andrew Paul Dawson

<p>The influence of highly regular, anisotropic, microstructured materials on high frequency ultrasonic wave propagation was investigated in this work. Microstructure, often only treated as a source of scattering, significantly influences high frequency ultrasonic waves, resulting in unexpected guided wave modes. Tissues, such as skin or muscle, are treated as homogeneous by current medical ultrasound systems, but actually consist of highly anisotropic micron-sized fibres. As these systems increase towards 100 MHz, these fibres will significantly influence propagating waves leading to guided wave modes. The effect of these modes on image quality must be considered. However, before studies can be undertaken on fibrous tissues, wave propagation in more ideal structures must be first understood. After the construction of a suitable high frequency ultrasound experimental system, finite element modelling and experimental characterisation of high frequency (20-200 MHz) ultrasonic waves in ideal, collinear, nanostructured alumina was carried out. These results revealed interesting waveguiding phenomena, and also identified the potential and significant advantages of using a microstructured material as an alternative acoustic matching layer in ultrasonic transducer design. Tailorable acoustic impedances were achieved from 4-17 MRayl, covering the impedance range of 7-12 MRayl most commonly required by transducer matching layers. Attenuation coefficients as low as 3.5 dBmm-1 were measured at 100 MHz, which is excellent when compared with 500 dBmm-1 that was measured for a state of the art loaded epoxy matching layer at the same frequency. Reception of ultrasound without the restriction of critical angles was also achieved, and no dispersion was observed in these structures (unlike current matching layers) until at least 200 MHz. In addition, to make a significant step forward towards high frequency tissue characterisation, novel microstructured poly(vinyl alcohol) tissue-mimicking phantoms were also developed. These phantoms possessed acoustic and microstructural properties representative of fibrous tissues, much more realistic than currently used homogeneous phantoms. The attenuation coefficient measured along the direction of PVA alignment in an example phantom was 8 dBmm-1 at 30 MHz, in excellent agreement with healthy human myocardium. This method will allow the fabrication of more realistic and repeatable phantoms for future high frequency tissue characterisation studies.</p>



Sign in / Sign up

Export Citation Format

Share Document