An automated planning strategy for near real-time adaptive proton therapy in prostate cancer

2018 ◽  
Vol 63 (13) ◽  
pp. 135017 ◽  
Author(s):  
Thyrza Jagt ◽  
Sebastiaan Breedveld ◽  
Rens van Haveren ◽  
Ben Heijmen ◽  
Mischa Hoogeman
2018 ◽  
Vol 127 ◽  
pp. S47-S48
Author(s):  
T. Jagt ◽  
S. Breedveld ◽  
B. Heijmen ◽  
M. Hoogeman

Healthcare ◽  
2019 ◽  
Vol 7 (4) ◽  
pp. 153
Author(s):  
Maria Antico ◽  
Peter Prinsen ◽  
Alice Fracassi ◽  
Alfonso Isola ◽  
David Cobben ◽  
...  

In prostate cancer external beam radiation therapy (EBRT), intra-fraction prostate drifts may compromise the treatment efficacy by underdosing the target and/or overdosing the organs at risk. In this study, a recently developed real-time adaptive planning strategy for intensity-modulated radiation therapy (IMRT) for prostate cancer was evaluated in hypofractionated regimes against traditional treatment planning based on a treatment volume margin expansion. The proposed workflow makes use of a “library of plans” corresponding to possible intra-fraction prostate positions. During delivery, at each beam end, the plan prepared for the position of the prostate closest to the current one is selected and the corresponding beam delivered. This adaptive planning strategy was compared with the traditional approach on a clinical prostate cancer case where different prostate shift magnitudes were considered. Five, six and fifteen fraction hypofractionated schemes were considered for each of these scenarios. When shifts larger than the treatment margin were present, using the traditional approach the seminal vesicles were underdosed by 3–4% of the prescribed dose. The adaptive approach instead allowed for correct target dose coverage and lowered the dose on the rectum for each dosimetric endpoint on average by 3–4% in all the fractionation schemes. Standard intensity-modulated radiation therapy planning did not always guarantee a correct dose distribution on the seminal vesicles and the rectum. The adaptive planning strategy proposed resulted insensitive to the intra-fraction prostate drifts, produced a dose distribution in agreement with the dosimetric requirements in every case analysed and significantly lowered the dose on the rectum.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Paulo Magalhaes Martins ◽  
Hugo Freitas ◽  
Thomas Tessonnier ◽  
Benjamin Ackermann ◽  
Stephan Brons ◽  
...  

AbstractProton therapy of prostate cancer (PCPT) was linked with increased levels of gastrointestinal toxicity in its early use compared to intensity-modulated radiation therapy (IMRT). The higher radiation dose to the rectum by proton beams is mainly due to anatomical variations. Here, we demonstrate an approach to monitor rectal radiation exposure in PCPT based on prompt gamma spectroscopy (PGS). Endorectal balloons (ERBs) are used to stabilize prostate movement during radiotherapy. These ERBs are usually filled with water. However, other water solutions containing elements with higher atomic numbers, such as silicon, may enable the use of PGS to monitor the radiation exposure of the rectum. Protons hitting silicon atoms emit prompt gamma rays with a specific energy of 1.78 MeV, which can be used to monitor whether the ERB is being hit. In a binary approach, we search the silicon energy peaks for every irradiated prostate region. We demonstrate this technique for both single-spot irradiation and real treatment plans. Real-time feedback based on the ERB being hit column-wise is feasible and would allow clinicians to decide whether to adapt or continue treatment. This technique may be extended to other cancer types and organs at risk, such as the oesophagus.


2005 ◽  
Vol 173 (4S) ◽  
pp. 145-145 ◽  
Author(s):  
Martin Schostak ◽  
Hans Krause ◽  
Jens Köllermann ◽  
Mark Schrader ◽  
Bernd Straub ◽  
...  

2006 ◽  
Vol 175 (4S) ◽  
pp. 485-486
Author(s):  
Sabarinath B. Nair ◽  
Christodoulos Pipinikas ◽  
Roger Kirby ◽  
Nick Carter ◽  
Christiane Fenske

Author(s):  
Hiroki Sato ◽  
Takahiro Kato ◽  
Tomoaki Motoyanagi ◽  
Kimihiro Takemasa ◽  
Yuki Narita ◽  
...  

Abstract In recent years, a novel technique has been employed to maintain a distance between the prostate and the rectum by transperineally injecting a hydrogel spacer (HS). However, the effect of HS on the prostate positional displacement is poorly understood, despite its stability with HS in place. In this study, we investigated the effect of HS insertion on the interfraction prostate motion during the course of proton therapy (PT) for Japanese prostate cancer patients. The study population consisted of 22 cases of intermediate-risk prostate cancer with 11 cases with HS insertion and 11 cases without HS insertion. The irradiation position and preparation were similar for both groups. To test for reproducibility, regular confirmation computed tomography (RCCT) was done four times during the treatment period, and five times overall [including treatment planning CT (TPCT)] in each patient. Considering the prostate position of the TPCT as the reference, the change in the center of gravity of the prostate relative to the bony anatomy in the RCCTs of each patient was determined in the left–right (LR), superior–inferior (SI) and anterior–posterior (AP) directions. As a result, no significant difference was observed across the groups in the LR and SI directions. Conversely, a significant difference was observed in the AP direction (P < 0.05). The proportion of the 3D vector length ≤5 mm was 95% in the inserted group, but 55% in the non-inserted group. Therefore, HS is not only effective in reducing rectal dose, but may also contribute to the positional reproducibility of the prostate.


2021 ◽  
Vol 60 (5) ◽  
pp. 598-604
Author(s):  
Kia Busch ◽  
Benjamin Dahl ◽  
Stine E. Petersen ◽  
Heidi S. Rønde ◽  
Lise Bentzen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document