Three-dimensional tomographically reconstructed optical emission profiles of Hall thruster plasmas

Author(s):  
jinwoo kim ◽  
Dongho Lee ◽  
Guentae Doh ◽  
Sanghoo Park ◽  
Holak Kim ◽  
...  

Abstract A diagnostic system was developed for spectrally resolved, three-dimensional tomographic reconstruction of Hall thruster plasmas, and local intensity profiles of Xe I and Xe II emissions were reconstructed. In this diagnostic system, 28 virtual cameras were generated using a single, fixed charge-coupled device (CCD) camera by rotating the Hall thruster to form a sufficient number of lines of sight. The Phillips-Tikhonov regularization algorithm was used to reconstruct local emission profiles from the line-integrated emission signals. The reconstruction performance was evaluated using both azimuthally symmetric and asymmetric synthetic phantom images including 5% Gaussian white noise, which resulted in a root-mean-square error of the reconstruction within an order of 10-3 even for a 1% difference in the azimuthal intensity distribution. Using the developed system, three-dimensional local profiles of Xe II emission (541.9 nm) from radiative decay of the excited state 5p4(3P2)6p2[3]˚5/2 and Xe I emission (881.9 nm) from 5p5(2P˚3/2)6p2[5/2]3 were obtained, and two different shapes were found depending on the wavelength and the distance from the thruster exit plane. In particular, a stretched central jet structure was distinctively observed in the Xe II emission profile beyond 10 mm from the thruster exit, while gradual broadening was found in the Xe I emission. Approximately 10% azimuthal nonuniformities were observed in the local Xe I and Xe II intensity profiles in the near-plume region (< 10 mm), which could not be quantitatively distinguished by analysis of the frontal photographic image. Three-dimensional Xe I and Xe II intensity profiles were also obtained in the plume region, and the differences in the structures of both emissions were visually confirmed.

1997 ◽  
Vol 51 (9) ◽  
pp. 1340-1345 ◽  
Author(s):  
F. Debal ◽  
M. Wautelet ◽  
J. P. Dauchot ◽  
M. Hecq

An experimental setup for spectroscopic optical tomography of glow discharges is presented. It combines a fiber-optics system with a monochromator coupled to a charge-coupled device (CCD) camera. The light emitted by the discharge is sent to the input of 10 optical fibers through a collimating system. The outputs of these optical fibers are coupled to the entrance slit of a monochromator. The CCD camera is in the output slit. This arrangement allowed us to acquire 10 spectra simultaneously, each being associated with a small zone of the discharge. By translation of the optical fibers, the whole discharge was studied. The data were then analyzed by means of a tomographic reconstruction program in order to obtain the three-dimensional spectroscopic optical tomography, for a large number of lines. This experimental setup was used to deduce the three-dimensional optical emission of various lines of a radio-frequency (rf)-powered magnetron discharge. The discharge deals with an aluminum base alloy cathode, sputtered by Ar. Emission lines corresponding to the cathode (Al: 394.4- and 396.2-nm lines) and the gas discharge (Ar: 763.5 nm-line) were considered. The three-dimensional emission profiles, I( r, Z), of the lines were measured; r is the distance from the center of the cathode, and Z is the distance from the cathode. I( r, Z) profiles are different for the Al and Ar lines. The effects of the electrical power and the pressure were also studied. It was found that the corresponding I( r, Z) profiles behave differently with the pressure. In order to compare the results, I( r, Z) was fitted with an empirical analytical mathematical function, with parameters depending on pressure. At high pressure, the shape of I( r, Z) for the Al line tends towards the shape of the Ar line.


Author(s):  
Neil Rowlands ◽  
Jeff Price ◽  
Michael Kersker ◽  
Seichi Suzuki ◽  
Steve Young ◽  
...  

Three-dimensional (3D) microstructure visualization on the electron microscope requires that the sample be tilted to different positions to collect a series of projections. This tilting should be performed rapidly for on-line stereo viewing and precisely for off-line tomographic reconstruction. Usually a projection series is collected using mechanical stage tilt alone. The stereo pairs must be viewed off-line and the 60 to 120 tomographic projections must be aligned with fiduciary markers or digital correlation methods. The delay in viewing stereo pairs and the alignment problems in tomographic reconstruction could be eliminated or improved by tilting the beam if such tilt could be accomplished without image translation.A microscope capable of beam tilt with simultaneous image shift to eliminate tilt-induced translation has been investigated for 3D imaging of thick (1 μm) biologic specimens. By tilting the beam above and through the specimen and bringing it back below the specimen, a brightfield image with a projection angle corresponding to the beam tilt angle can be recorded (Fig. 1a).


Author(s):  
J. Frank ◽  
B. F. McEwen ◽  
M. Radermacher ◽  
C. L. Rieder

The tomographic reconstruction from multiple projections of cellular components, within a thick section, offers a way of visualizing and quantifying their three-dimensional (3D) structure. However, asymmetric objects require as many views from the widest tilt range as possible; otherwise the reconstruction may be uninterpretable. Even if not for geometric obstructions, the increasing pathway of electrons, as the tilt angle is increased, poses the ultimate upper limitation to the projection range. With the maximum tilt angle being fixed, the only way to improve the faithfulness of the reconstruction is by changing the mode of the tilting from single-axis to conical; a point within the object projected with a tilt angle of 60° and a full 360° azimuthal range is then reconstructed as a slightly elliptic (axis ratio 1.2 : 1) sphere.


Author(s):  
C.L. Woodcock

Despite the potential of the technique, electron tomography has yet to be widely used by biologists. This is in part related to the rather daunting list of equipment and expertise that are required. Thanks to continuing advances in theory and instrumentation, tomography is now more feasible for the non-specialist. One barrier that has essentially disappeared is the expense of computational resources. In view of this progress, it is time to give more attention to practical issues that need to be considered when embarking on a tomographic project. The following recommendations and comments are derived from experience gained during two long-term collaborative projects.Tomographic reconstruction results in a three dimensional description of an individual EM specimen, most commonly a section, and is therefore applicable to problems in which ultrastructural details within the thickness of the specimen are obscured in single micrographs. Information that can be recovered using tomography includes the 3D shape of particles, and the arrangement and dispostion of overlapping fibrous and membranous structures.


Author(s):  
Robert W. Mackin

This paper presents two advances towards the automated three-dimensional (3-D) analysis of thick and heavily-overlapped regions in cytological preparations such as cervical/vaginal smears. First, a high speed 3-D brightfield microscope has been developed, allowing the acquisition of image data at speeds approaching 30 optical slices per second. Second, algorithms have been developed to detect and segment nuclei in spite of the extremely high image variability and low contrast typical of such regions. The analysis of such regions is inherently a 3-D problem that cannot be solved reliably with conventional 2-D imaging and image analysis methods.High-Speed 3-D imaging of the specimen is accomplished by moving the specimen axially relative to the objective lens of a standard microscope (Zeiss) at a speed of 30 steps per second, where the stepsize is adjustable from 0.2 - 5μm. The specimen is mounted on a computer-controlled, piezoelectric microstage (Burleigh PZS-100, 68/μm displacement). At each step, an optical slice is acquired using a CCD camera (SONY XC-11/71 IP, Dalsa CA-D1-0256, and CA-D2-0512 have been used) connected to a 4-node array processor system based on the Intel i860 chip.


2012 ◽  
Vol 17 (4) ◽  
pp. 319-326 ◽  
Author(s):  
Zbigniew Chaniecki ◽  
Krzysztof Grudzień ◽  
Tomasz Jaworski ◽  
Grzegorz Rybak ◽  
Andrzej Romanowski ◽  
...  

Abstract The paper presents results of the scale-up silo flow investigation in based on accelerometer signal analysis and Wi-Fi transmission, performed in distributed laboratory environment. Prepared, by the authors, a set of 8 accelerometers allows to measure a three-dimensional acceleration vector. The accelerometers were located outside silo, on its perimeter. The accelerometers signal changes allowed to analyze dynamic behavior of solid (vibrations/pulsations) at silo wall during discharging process. These dynamic effects are caused by stick-slip friction between the wall and the granular material. Information about the material pulsations and vibrations is crucial for monitoring the interaction between silo construction and particle during flow. Additionally such spatial position of accelerometers sensor allowed to collect information about nonsymmetrical flow inside silo.


2020 ◽  
Vol 11 (1) ◽  
pp. 301
Author(s):  
Sławomir Paśko ◽  
Wojciech Glinkowski

Scoliosis is a three-dimensional trunk and spinal deformity. Patient evaluation is essential for the decision-making process and determines the selection of specific and adequate treatment. The diagnosis requires a radiological evaluation that exposes patients to radiation. This exposure reaches hazardous levels when numerous, repetitive radiographic studies are required for diagnostics, monitoring, and treatment. Technological improvements in radiographic devices have significantly reduced radiation exposure, but the risk for patients remains. Optical three-dimensional surface topography (3D ST) measurement systems that use surface topography (ST) to screen, diagnose, and monitor scoliosis are safer alternatives to radiography. The study aimed to show that the combination of plain X-ray and 3D ST scans allows for an approximate presentation of the vertebral column spinous processes line in space to determine the shape of the spine’s deformity in scoliosis patients. Twelve patients diagnosed with scoliosis, aged 13.1 ± 4.5 years (range: 9 to 20 years) (mean: Cobb angle 17.8°, SD: ±9.5°) were enrolled in the study. Patients were diagnosed using full-spine X-ray and whole torso 3D ST. The novel three-dimensional assessment of the spinous process lines by merging 3D ST and X-ray data in patients with scoliosis was implemented. The method’s expected uncertainty is less than 5 mm, which is better than the norm for a standard measurement tool. The presented accuracy level is considered adequate; the proposed solution is accurate enough to monitor the changes in the shape of scoliosis’s spinous processes line. The proposed method allows for a relatively precise calculation of the spinous process lines based on a three-dimensional point cloud obtained with a four-directional, three-dimensional structured light diagnostic system and a single X-ray image. The method may help reduce patients’ total radiation exposure and avoid one X-ray in the sagittal projection if biplanar radiograms are required for reconstructing the three-dimensional line of the spinous processes line.


Author(s):  
GUANGYI CHEN ◽  
TIEN D. BUI ◽  
ADAM KRZYZAK

The denoising of a natural signal/image corrupted by Gaussian white noise is a classical problem in signal/image processing. However, it is still in its infancy to denoise high dimensional data. In this paper, we extended Sendur and Selesnick's bivariate wavelet thresholding from two-dimensional (2D) image denoising to three-dimensional (3D) data cube denoising. Our study shows that bivariate wavelet thresholding is still valid for 3D data cubes. Experimental results show that bivariate wavelet thresholding on 3D data cube is better than performing 2D bivariate wavelet thresholding on every spectral band separately, VisuShrink, and Chen and Zhu's 3-scale denoising.


Sign in / Sign up

Export Citation Format

Share Document