scholarly journals Numerical Investigation of Precast Grouted Sleeve Connection under Cyclic Loading Using ABAQUS

2021 ◽  
Vol 2070 (1) ◽  
pp. 012178
Author(s):  
A. Hemamathi ◽  
Sanjith Murugavel ◽  
Binu Sukumar ◽  
M. Usha Rani

Abstract This paper deals with numerical investigation using finite element software, ABAQUS CAE, for the analysis of precast reinforced concrete (RC) column connected to the foundation containing protruding bar in grouted sleeve subjected to axial, and lateral loads, including the cyclic loading response. The monolithic connection of column and foundation is designed and the same has been used for the design of precast concrete column and foundation. The model focusses on the length of the protruding bar provided in the foundation that is connected to the column through the grouted sleeve. As there is lack of Indian standard codes in the design of precast concrete connections, an attempt has been made by varying the length of protruding bars. The model was subjected to quasi-static loading condition and parameters such as ultimate load carrying capacity, load-displacement hysteresis, ductility and plastic strain were studied and were compared with that of monolithic connection. The results proved that when the length of protruding bars provided was equal to development length of the bar provided, the results were comparable with that of monolithic connection.

2018 ◽  
Vol 7 (3.35) ◽  
pp. 5 ◽  
Author(s):  
M. Sivaraj ◽  
Dr. R. Sundararajan ◽  
K. Vivek ◽  
Dr. T. Senthil Vadivel

Among various building materials, concrete is the most widely used conventional material. Nowadays many scientists are on a hunt for a substitute material for constructionthat is eco-friendly and made from industrial waste products and offer sustainable development. In this study, cement was partially substituted by metakaolin of varying percentage as 0%, 2.5%, 5%, 7.5% and 10% by weight of cement. Shredded plastic waste of 0.5% by weight was added to concrete by replacing coarse aggregate in the concrete. M20 grade concrete is used for beams. Optimum replacement percentage of metakaolin was determined from the tests. Ultimate load carrying capacity of beams produced with the optimum replacement percentage was compared with the numerical investigation done by finite element modelling package ANSYS 12.0. 


Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3468
Author(s):  
Zbigniew Kolakowski ◽  
Andrzej Teter

The phenomena that occur during compression of hybrid thin-walled columns with open cross-sections in the elastic range are discussed. Nonlinear buckling problems were solved within Koiter’s approximation theory. A multimodal approach was assumed to investigate an effect of symmetrical and anti-symmetrical buckling modes on the ultimate load-carrying capacity. Detailed simulations were carried out for freely supported columns with a C-section and a top-hat type section of medium lengths. The columns under analysis were made of two layers of isotropic materials characterized by various mechanical properties. The results attained were verified with the finite element method (FEM). The boundary conditions applied in the FEM allowed us to confirm the eigensolutions obtained within Koiter’s theory with very high accuracy. Nonlinear solutions comply within these two approaches for low and medium overloads. To trace the correctness of the solutions, the Riks algorithm, which allows for investigating unsteady paths, was used in the FEM. The results for the ultimate load-carrying capacity obtained within the FEM are higher than those attained with Koiter’s approximation method, but the leap takes place on the identical equilibrium path as the one determined from Koiter’s theory.


2018 ◽  
Vol 22 (7) ◽  
pp. 1554-1565 ◽  
Author(s):  
Jianwei Tu ◽  
Kui Gao ◽  
Lang He ◽  
Xinping Li

At present, extensive studies have been conducted relative to the topic of fiber-reinforced polymer(FRP)- reinforced concrete (RC) flexural members, and many design methods have also been introduced. There have, however, been few studies conducted on the topic of FRP-RC compression members. In light of this, eight glass-fiber-reinforced polymer (GFRP)-RC square columns (200×200×600 mm) were tested in order to investigate their axial compression performance. These columns were reinforced with GFRP longitudinal reinforcement and confined GFRP stirrup. These experiments investigated the effects of the longitudinal reinforcement ratio, stirrup configuration (spirals versus hoops) and spacing on the load-carrying capacity and failure modes of GFRP-RC rectangular columns. The test results indicate that the load-carrying capacity of longitudinal GFRP bars accounted for 3%-7% of the ultimate load-carrying capacity of the columns. The ultimate load-carrying capacity of RC columns confined with GFRP spirals increased by 0.8%-1.6% with higher ductility, compared to GFRP hoops. Reducing the stirrup spacing may prevent the buckling failure of the longitudinal bars and increase the ductility and load-carrying capacity of the GFRP-RC columns. It has been found that setting the GFRP compressive strength to 35% of the GFRP maximum tensile strength yields a reasonable estimate of ultimate load-carrying capacity of GFRP-RC columns.


2003 ◽  
Vol 1845 (1) ◽  
pp. 191-199 ◽  
Author(s):  
Ondrej Kalny ◽  
Robert J. Peterman ◽  
Guillermo Ramirez ◽  
C. S. Cai ◽  
Dave Meggers

Stiffness and ultimate load-carrying capacities of glass fiber-reinforced polymer honeycomb sandwich panels used in bridge applications were evaluated. Eleven full-scale panels with cross-section depths ranging from 6 to 31.5 in. (152 to 800 mm) have been tested to date. The effect of width-to-depth ratio on unit stiffness was found to be insignificant for panels with a width-to-depth ratio between 1 and 5. The effect of this ratio on the ultimate flexural capacity is uncertain because of the erratic nature of core-face bond failures. A simple analytical formula for bending and shear stiffness, based on material properties and geometry of transformed sections, was found to predict service-load deflections within 15% accuracy. Although some factors influencing the ultimate load-carrying capacity were clearly identified in this study, a reliable analytical prediction of the ultimate flexural capacity was not attained. This is because failures occur in the bond material between the outer faces and core, and there are significant variations in bond properties at this point due to the wet lay-up process, even for theoretically identical specimens. The use of external wrap layers may be used to shift the ultimate point of failure from the bond (resin) material to the glass fibers. Wrap serves to strengthen the relatively weak core–face interface and is believed to bring more consistency in determining the ultimate load-carrying capacity.


Mechanika ◽  
2019 ◽  
Vol 25 (6) ◽  
pp. 426-433 ◽  
Author(s):  
Tao LAN

In this paper, load-carrying and deformation capacity of tension lap splices that have both welds and bolts acting in the same shear plane are studied using numerical method. The failure criterion of bolts and welds are given based on the finite element calculation and compared with existing experiment results, it shows that the established numerical model is correct and reliable. The strength of longitudinal welds and the bearing capacity of the high-strength bolts before slipping can be fully used in the combined joints, the bolts and welds fail almost simultaneously. The deformation of welds in combined connections is less uniform than its’ deformation in welded joints as the welds fails, and it causes the deformation of welds as failure is larger in combined connections than in welded connections. The deformation capacity of the combined joint are slightly increased contrasted with bolts joint and welds joint because of the interplay of bolts and welds acting in the same shear plane. The strengths of welds and bolts performed in combined connections can reach 0.95 and the deformation of combined connection is increased at least 1.10 times as the welds connection or the bolts connection.


2019 ◽  
Vol 22 (13) ◽  
pp. 2755-2770
Author(s):  
Fuyun Huang ◽  
Yulong Cui ◽  
Rui Dong ◽  
Jiangang Wei ◽  
Baochun Chen

When casting wet concrete into hollow steel tubular arch during the construction process of a concrete-filled steel tubular arch bridge, an initial stress (due to dead load, etc.) would be produced in the steel tube. In order to understand the influence of this initial stress on the strength of the concrete-filled steel tubular arch bridge, a total of four single tubular arch rib (bare steel first) specimens (concrete-filled steel tubular last) with various initial stress levels were constructed and tested to failure. The test results indicate that the initial stress has a large influence on the ultimate load-carrying capacity and ductility of the arch structure. The high preloading ratio will reduce significantly the strength and ductility that the maximum reductions are over 25%. Then, a finite element method was presented and validated using the test results. Based on this finite element model, a parametric study was performed that considered the influence of various parameters on the ultimate load-carrying capacity of concrete-filled steel tubular arches. These parameters included arch slenderness, rise-to-span ratio, loading method, and initial stress level. The analysis results indicate that the initial stress can reduce the ultimate loading capacity significantly, and this reduction has a strong relationship with arch slenderness and rise-to-span ratio. Finally, a method for calculating the preloading reduction factor of ultimate load-carrying capacity of single concrete-filled steel tubular arch rib structures was proposed based on the equivalent beam–column method.


2013 ◽  
Vol 795 ◽  
pp. 190-194
Author(s):  
S. Samsuddin ◽  
I. Ahmad ◽  
W.I. Goh ◽  
N. Mohamad ◽  
Abdul Aziz Abdul Samad ◽  
...  

This report provides experimental data on the development of PLFP for building construction. An innovative concept was used in the design of this system and the use of lightweight foamed concrete was discussed. Preliminary result of PLFP with double shear truss connectors was analysed and presented. PLFP was tested to determine its ultimate load carrying capacity under axial loading. Ultimate load carrying capacity, load deflection profile, surface strains and crack pattern were recorded and analysed. Test results were compared with calculated values based on classical formulas that developed by previous researchers and experimental data from previous researchers on its compositeness in between wythes. Results shown that PLFP with double shear truss connectors achieved higher compositeness in between wythes and have adequate ultimate load carrying capacity.


Sign in / Sign up

Export Citation Format

Share Document