scholarly journals Procedure for calculation of the admissible continuous power transmission currents of overhead wires and contact lines

2021 ◽  
Vol 2131 (4) ◽  
pp. 042065
Author(s):  
Yu I Zharkov ◽  
E P Figurnov ◽  
V I Kharchevnikov

Abstract The proposed methodology summarizes published and original domestic and foreign theoretical and experimental materials on heating and cooling of spiral and shaped wires of overhead power transmission lines and electric power systems and uses those of them that best meet the fundamental laws of heat transfer. Formulas for calculating the surface area for spiral and shaped wires are given. A generalized formula for the convective heat transfer coefficient taking into account the direction and speed of the wind, including for the anti-ice regime, is given. The parameters of this formula do not coincide with the existing ones, since they are based on the experimental data for spiral and shaped wires, and not for round pipes. The formula for calculating the power of heat transfer under solar radiation is given. A generalized formula is given for calculating the continuous allowable current, all components of which are described in detail in the article.

2018 ◽  
Vol 58 ◽  
pp. 01010 ◽  
Author(s):  
Nikolay Belyaev ◽  
Andrey Egorov ◽  
Nikolay Korovkin ◽  
Vladimir Chudny

The present report deals with economic issues of selecting means ensuring the capacity adequacy of electric power systems. Cost analysis of various engineering measures ensuring the capacity adequacy has been performed, they are as follows: construction of margin generating capacities, erection of new power transmission lines or increase of transmission capacity of existing power lines. The cost-based analysis has been conducted following investment programs and regulatory acts in place. Recommendations on developing computational models of power systems have been given based on the results obtained in order to assess the capacity adequacy indices with account made for the cost of various engineering measures to be taken for their improvement.


Author(s):  
E. M. Farhadzadeh ◽  
A. Z. Muradaliyev ◽  
S. A. Abdullayeva ◽  
A. A. Nazarov

Basic EPS objects, which service life has exceeded normative value, increasingly affect – every year to a greater extent – the efficiency of overall performance. This manifests itself in increase of a number of automatic emergency shutdowns, an amount and complexities of accident-hazardous defects. After the expiration of the standard service life, there is a special need for a quantitative assessment of reliability and safety of an object. It is recommended to organize the operation, maintenance and repair of these objects according to their technical condition, and since it determines the reliability and safety of the object, these properties should be taken into account more fully. The relevant recommendations in electric power systems are implemented at a qualitative level, intuitively, according to the operating experience. There are neither quantitative evaluations nor methodology for their performance. Therefore, a method and algorithm of quantitative assessment of integral indicators of reliability and safety of operation of thermal power units of thermal power plants as concentrated objects of continuous operation were previously analyzed by the authors. The present paper examines distributed objects of continuous operation, viz. overhead power transmission lines with a voltage of 110 kV and higher, whose service life exceeds the standard value. Attention is paid to the issues of quantitative assessment of the degree of aging for a set of overhead power transmission lines, classification of these lines to identify the most significant classes and methodology for assessing the difference in the degree of aging when classifying them according to specified types of signs (for example, the difference in the degree of aging of overhead power transmission lines of grid enterprises of electric power systems). It is shown that it unacceptable to use the estimates of the relative number of overhead power transmission lines, the service life of which exceeds the calculated one, for comparison since it causes a great risk of an erroneous decision. The methodology and algorithm of methodological support of the management of electric power systems and grid enterprises in the organization of operation, maintenance and repair have been developed.


2021 ◽  
Vol 14 (2) ◽  
pp. 100-107
Author(s):  
E. M. Farhadzadeh ◽  
A. Z. Muradalyiev ◽  
S. A. Muradalyiev ◽  
A. A. Nazarov

The organization of operation, maintenance and repair of the basic technological facilities of electric power systems (EPS), which are beyond their designed service life (hereinafter referred to as ageing facilities, or AFs) is one of the problems that determine the energy security of many countries, including economically developed nations. The principal cause of insufficient overall performance of AFs is the traditional focus of the EPS management on economic efficiency and the insufficient attention to reliability and safety of AFs. The tendency to nonlinear growth in the frequency of occurrence of unacceptable consequences in the EPS requires ensuring the operational reliability and safety of AFs. The averaged estimates of reliability and safety used at designing power facilities are not suitable for characterization of overall operational performance. Among the basic and the least investigated (in terms of operational reliability and safety) EPS facilities are overhead power transmission lines (OPL) with a voltage of 110 кV and above. This is for a reason. OPL are electric power facilities with elements distributed along a multi-kilometer line (supports, insulators, wires, accessories, etc.). That is what makes the organization of continuous monitoring of the technical condition of each of these elements, and, consequently, the assessment of operational reliability and safety, so problematic. A method is suggested for assessment of “weak links” among the operated OPL on operative intervals of time along with a method for assessment of the technical condition of OPL at examination of a representative sample.


2021 ◽  
Vol 2 (2) ◽  
pp. 36-43
Author(s):  
Evgeniy P. FIGURNOV ◽  
◽  
Yury I. ZHARKOV ◽  
Valeriy I. KHARCHEVNIKOV ◽  
◽  
...  

Methodology provided summarizes published, original and foreign theoretic and experimental data on the subject of heating and cooling of standard and shaped conductors of overhead power transmission line and uses those of them which are most affected to fundamental heat-transfer laws. Computation surface area of standard and shaped wire formulas are given. The common formula of convection heat transfer coefficient is provided, based on wind speed and direction, concerning antiicing mode. Parameters of this formula do not coincide with those existing, as they are based on experimental data on standard and shaped conductors but not on round tubes. Formula of computation of heat transfer power under the influence of solar radiation is given. Summarized formula of admissible continuous current computation is given, all the components have detailed description in the article.


2021 ◽  
Author(s):  
Sergey Goremykin

The textbook describes the main issues of the theory of relay protection and automation of electric power systems. The structure and functional purpose of protection devices and automation of power transmission lines of various configurations, synchronous generators, power transformers, electric motors and individual electrical installations are considered. For each of the types of protection of the above objects, the structure, the principle of operation, the order of selection of settings are given, the advantages and disadvantages are evaluated, indicating the scope of application. The manual includes material on complete devices based on semiconductor and microprocessor element bases. The progressive use of such devices (protection of the third and fourth generations) is appropriate and effective due to their significant advantages. Meets the requirements of the federal state educational standards of higher education of the latest generation. It is intended for students in the areas of training 13.03.02 "Electric power and electrical engineering" (profile "Power supply", discipline "Relay protection and automation of electric power systems") and 35.03.06 "Agroengineering" (profile "Power supply and electrical equipment of agricultural enterprises", discipline "Relay protection of electrical equipment of agricultural objects"), as well as for graduate students and specialists engaged in the field of electrification and automation of industrial and agrotechnical objects.


2020 ◽  
Vol 23 (2) ◽  
pp. 16-19
Author(s):  
G. SHEINA ◽  

This paper investigates a mathematical model of one elements of the power supply system - power transmission lines. The type of models depends on the initial simplifications, which in turn are determined by the complexity of the physics of processes. The task of improving the accuracy of modeling of emergency processes in the power system is due to the significant complexity of modern power systems and their equipment, high-speed relay protection, automation of emergency management and the introduction of higher-speed switching equipment. One of the reasons for a significant number of serious emergencies in the system is the lack of complete and reliable information for modeling modes in the design and operation of power systems. The development of a mathematical model of a three-phase power line, which provides adequate reflection of both normal and emergency processes, is relevant. The advanced mathematical model of power transmission lines allows to investigate various operational modes of electric networks. The improved mathematical model of the power transmission line reflects all the features of physical processes at state modes and transient process and provides sufficient accuracy of the results. The type of mathematical model of power transmission lines depends on the accepted simplifications, depending on the task of research. The purpose of this work is to analyze the mathematical model of the power transmission line to study the modes of operation of the power supply system, with the possibility of its application to take into account all the design features of overhead and cable power lines. The mathematical model of the power line for the study of the modes of operation of the power supply system is analyzed. It is used to take into account the design features of overhead and cable power lines, skin effect.


2014 ◽  
Vol 577 ◽  
pp. 551-555
Author(s):  
Hui Li ◽  
Liang Yuan

Single of phasor measurement unit (PMU) in smart grid is analyzed. On the power transmission links, single of voltage and current are measured by kinds of PMUs, messages of PMUs are concentrated to PDC (Phasor data concentrator) and super PDC in power systems. Signal quality is important to power transmission, power utilization and power control for stability a power system. Harmonics, inter-harmonics, decaying DC (direct current) offset, and additive white Gaussian noise are analyzed. Odd-number harmonics and inter-harmonics affect the quality of power signals. Decaying DC offsert components influence current signal of power transmission line whose model is modeled by EMTP (Electromagnetic transient program) worldwide. Noise is generally a negligible factor on power transmission lines, since signal-to-noise (SNR) is always below 40 dB.


Energies ◽  
2019 ◽  
Vol 12 (7) ◽  
pp. 1193 ◽  
Author(s):  
Zuzana Bukvisova ◽  
Jaroslava Orsagova ◽  
David Topolanek ◽  
Petr Toman

This work analyses a two-terminal algorithm designed to locate unsymmetrical faults on 110 kV power transmission lines. The algorithm processes synchronized voltage and current data obtained from both ends of the protected transmission line and calculates the distance of the fault. It is based on decomposing the equivalent circuit into the positive-, negative- and zero-sequence components and finding the point where the output voltages of the right and the left side of the transmission line are equal. Compared to the conventional distance relay locator, the accuracy of this method is higher and less influenced by the fault resistance, the parallel-operated line effect and line asymmetry, as discussed in this work. It is, however, very sensitive to the synchronization accuracy. The mathematical model of the power system was created in the PSCAD (Power Systems Computer Aided Design) environment and the computational algorithm was implemented in Mathematica software.


2021 ◽  
Vol 15 ◽  
Author(s):  
D. Kalpaktsoglou ◽  
A. Tsiakalos ◽  
S. Pouros ◽  
Μ. Roumeliotis

This paper compares by simulation the Thyristor Switched Series Capacitors (TSSC) Circuit with the Thyristor Switched Parallel Capacitors (TSPC) Circuit for wind turbines. The well-known TSSC circuit belongs to the Controlled Series Capacitor (CSC) circuits that have been used in power transmission lines in order to correct the power factor and improve the performance of the electrical system. Such a circuit can be used in wind power systems to improve and maximize the efficiency of a wind turbine. A typical direct-drive wind power system employs variable speed electric generators, but the downside is that systems like that suffer from high inductive reactance. A TSSC circuit, therefore, is able to counteract for any reactive losses, and improve the power factor as well as the efficiency. The main issue with the TSSC circuit is the use of a high number of capacitors that must be connected in series, which can increase the cost and the maintenance of the controller. This paper introduces a novel circuit with different control technique than the TSSC that employs capacitors in parallel configuration. The novel TSPC circuit was simulated in PSPICE and the benefits as well as the drawbacks are described


Sign in / Sign up

Export Citation Format

Share Document