scholarly journals Identification of low-voltage connection relation in distribution platform based on similarity of voltage curve and grey correlation degree of entropy weight

2021 ◽  
Vol 2137 (1) ◽  
pp. 012019
Author(s):  
Yuehao Yan ◽  
Wei Bao ◽  
Lijiao Li ◽  
Zongjie Wang

Abstract The correct low-voltage connection relationship in distribution area is of great significance to the safe operation and efficient management of power grid. As there are many reconstruction projects in the low-voltage platform area, the assets change frequently, and the interconnection perception ability of the low-voltage platform area is weak, which brings great difficulties to the identification of the user connection relationship. Traditional identification methods are heavy and inefficient. This paper proposes a method based on trend similarity and distance measure to identify low-voltage connection relation in distribution platform area. Firstly, Pearson correlation coefficient and discrete Fréchet distance are calculated to measure the trend similarity of voltage curve, and abnormal users are found out. GIS is used to search for adjacent stations, and finally, the correct station area of users is determined by analyzing the entropy weight grey correlation degree. The applicability and correctness of the proposed algorithm are verified by the application results of an example.

2020 ◽  
Vol 165 ◽  
pp. 06033
Author(s):  
Zhang Lin ◽  
Zhang Qinghe ◽  
Zhang Xue ◽  
Gao Hui

With the development of new energy and flexible load, there are many kinds of power and load characters in the power grid. It’s necessary to considerate the similarity between generation output and load when it’s market clearing. First, similarity analysis of generation-load curve based on the grey correlation degree is introduced, correlation between power generation enterprises and power users can be calculated. Then, market clearing model is built. market clearing mechanism is set which considering the matching degree between generation and load. The technological process of market clearing is given. Last, the effectiveness of the proposed clearing model is verified by an example.


2013 ◽  
Vol 345 ◽  
pp. 507-510
Author(s):  
Rong Gu ◽  
Jin Sha Yuan ◽  
Fei Lv

Accurate assessment for the operational status of the transformer bushing is not only a prerequisite for the implementation of condition-based maintenance, but also to ensure the normal operation of the transformer and the whole power equipment conditions. In the paper, a model of weight absolute grey correlation degree was used to assess the transformer bushing state. Firstly, determined the assessment indicators and handled them. Secondly, the weights, correlation coefficients and each association were calculated. Thirdly, to compare the largest association of assessment indicators in grades as the transformer bushing final run state. Finally, give the state assessment results, according to the remark set. The result shows the model works well.