scholarly journals A multistage heat pump unit model for reducing energy consumption of space heating at low ambient temperatures

2021 ◽  
Vol 1100 (1) ◽  
pp. 012045
Author(s):  
A S Kosoi ◽  
Y A Antipov ◽  
K V Shkarin ◽  
I K Shatalov ◽  
D D Sokolov
Author(s):  
Bing Wei ◽  
Huayi Yang

Nowadays the energy crisis has been more and more severe all over the world. In China there is enormous energy source, but due to the large number of population, the average possession of the total energy is lower, and the energy supply is relatively less. Enormous energy consumption of air conditioning systems in the residential buildings makes the energy conservation more important. The residential central air conditioning systems are being widely used due to its advantages of easy control and low operating cost. But there are still many problems to be resolved, of which the energy consumption of the residential central air-conditioning systems is a hot issue. The main cold and heat sources for residential central air conditioning systems are air-cooled heat pump unit, household gas air conditioning unit, air-cooled chiller unit/gas-fired boiler and water loop heat pump unit. The terminal facilities suited for the anterior three units are the fan coil units, and the terminal of the last water loop heat pump unit is normally indoor unit. The combined utilization of the heat and cold source units with their terminal units keep the indoor environment in desired state all the year. In this paper, based on an actual example, the basic principles of four systems mentioned above are outlined and analyzed, and four schemes are compared. By using the method of equivalent weight full load operation time, the annual energy consumptions of the four schemes are calculated and analyzed. Comparing the annual primary energy consumption of four schemes, the following conclusions can be drawn: in the case studied, the energy consumption of the household gas-fired air conditioning unit with fan coil system is the maximum, the consumption of the air-cooled chiller unit/gas-fired boiler with fan coil system is the next, then is the air-cooled heat pump with fan coil system, and that of the water loop heat pump system is the minimum. It can be observed that the water loop heat pump system is the optimal one and is the best on energy conservation. Through the study of this paper, the minimum energy consumption system is chosen so as to give the references for the energy savings of air-conditioning systems in the practice.


2015 ◽  
Vol 8 (1) ◽  
pp. 38-42
Author(s):  
Pengfei Si ◽  
Xiangyang Rong ◽  
Angui Li ◽  
Xiaodan Min ◽  
Zhengwu Yang ◽  
...  

As a realization of the energy cascade utilization, the regional energy system has the significant potential of energy saving. As a kind of renewable energy, river water source heat pump also can greatly reduce the energy consumption of refrigeration and heating system. Combining the regional energy and water source heat pump technology, to achieve cooling, heating and power supply for a plurality of block building is of great significance to reduce building energy consumption. This paper introduces a practical engineering case which combines the regional energy system of complex river water source heat pump, which provides a detailed analysis of the hydrology and water quality conditions of the river water source heat pump applications, and discusses the design methods of water intake and drainage system. The results show that the average temperature of cold season is about 23.5 °C, the heating season is about 13.2 °C; the abundant regional water flow can meet the water requirement of water source heat pump unit; the sediment concentration index cannot meet the requirement of river water source heat pump if the water enters the unit directly; the river water chemistry indicators (pH, Cl-, SO42-, total hardness, total iron) can meet the requirement of river water source heat pump, and it is not required to take special measures to solve the problem. However, the problem of sediment concentration of water must be solved.


2011 ◽  
Vol 121-126 ◽  
pp. 2162-2166
Author(s):  
Yan Mei Meng ◽  
Hai Feng Pang ◽  
Ying Ning Hu ◽  
Quan Zhou ◽  
Dao Yang Li ◽  
...  

This paper describes the research and implementation of ground source heat pump unit remote real-time monitoring system, researches in remote real-time monitoring system's overall design, hardware design, software design and implementation of OPC communication. The host computer takes advantage of the human-computer interaction interface of configuration software to achieve the remote real-time monitoring for ground source heat pump unit's running state; the lower computer uses data collector to intensively collect the data which is measured by field measuring instruments, and to achieve remote data transmission based on Ethernet, and then to carry out the communication between the host computer and the lower computer via OPC technology. The results show that the system achieves remote real-time monitoring of ground source heat pump unit, and is stable, easy to operate and provides a reliable basis for the actual energy saving effect's evaluation of ground source heat pump system.


2017 ◽  
Vol 204 ◽  
pp. 679-689 ◽  
Author(s):  
Mengjie Song ◽  
Xiangguo Xu ◽  
Ning Mao ◽  
Shiming Deng ◽  
Yingjie Xu

2012 ◽  
Vol 608-609 ◽  
pp. 1241-1245
Author(s):  
Wei Qiu ◽  
Li Zhang ◽  
Qing Rong liu

This paper analyses the energy consumption of water source heat pump, shows that the performance coefficient of water source heat pump unit is directly related to the temperature of water resources, and discusses the feasibility of central heating by recovering condensing heat of power plant using water source heat pump unit. It analyzes the energy saving benefit of water source heat pump unit is significant compared with traditional heating. Using the technology recovers waste heat of power plant, which can not only decrease the energy waste on the direct discharge of waste heat and water, but at the same time, it is a new air conditioning system without environmental pollution.


2013 ◽  
Vol 475-476 ◽  
pp. 192-197
Author(s):  
Jian Wen Feng ◽  
Li Peng Wang

Performance test-bed of heat pump unit in central air-conditioner needs the intelligent and multifunctional software. So the monitoring software is designed with a good human-machine interactive interface, based on Visual C# development platform. The software can dynamically configure channels and measurement points to improve the defects of fixed channels for all measuring points in the traditional monitoring systems, which enhanced the flexibility and reliability of system. In order to increase the data accuracy, the improved digital filter algorithm was adopted. In addition, multi-threading mechanism was used to achieve serial communication and data processing, which meets the requirements of monitoring program for multi-tasking and real-time. The results show that monitoring software is powerful, easy to operate, reliable, high fault-tolerant and good user-friendly. It is suitable for using in other monitoring systems.