scholarly journals Development length on concrete with bundle bars

Author(s):  
E Walujodjati
Keyword(s):  
1981 ◽  
Vol 103 (3) ◽  
pp. 471-477 ◽  
Author(s):  
W. F. Phillips

Theoretical results are presented which predict the entrainment coefficient in a forced plume as a function of the local Froude number. The model does not require any external specification of the velocity and temperature profiles. The Froude number for any plume, in a motionless isothermal ambient, approaches a universal constant, at a large distance above the source. However, it is shown here that the development length for the Froude number, in plumes with high discharge Froude number, is of the order of a few hundred times the discharge width.


Author(s):  
Amir Farid Momeni ◽  
Robert J. Peterman ◽  
B. Terry Beck ◽  
Chih-Hang John Wu ◽  
Naga Narendra B. Bodapati

A study was conducted to determine the effect of concrete release strength on the development length and flexural capacity of members utilizing five different 5.32-mm-diameter prestressing wires that are commonly used in the manufacture of prestressed concrete railroad ties worldwide. These included two chevron-indented wires with different indent depths, one spiral-indented wire, one dot-indented wire, and one smooth wire (with no surface indentation). A consistent concrete mixture was used for the manufacture of all test specimens, and the different release strengths were obtained by allowing the specimens to cure for different amounts of time prior to de-tensioning. Each prismatic specimen (prism) had a 3.5″ (88.9 mm) × 3.5″ (88.9 mm) square cross section with four wires arranged symmetrically. The prisms were identical except for the wire type and the compressive strength at the time of de-tensioning. All four wires were each initially tensioned to 7000 pounds (31.14 KN) and then de-tensioned gradually when the concrete compressive strength reached 3500 (24.13 MPa), 4500 (31.03 MPa) and 6000 (41.37 MPa) psi. Precise de-tensioning strengths were ensured by testing 4-in.-diameter (101.6 mm) × 8-in.-long (203.2 mm) compression strength cylinders that were temperature match-cured. The prisms were loaded in 3-point-bending to determine the ultimate bond characteristics of each reinforcement type for the different concrete release strengths. A loading rate of 300 lb/min (1334 N/min) was applied at mid-span and the maximum sustained moment was calculated for each test. Two 69-in.-long (175.26 cm) prisms, each having different concrete release strength, were tested with each of the 5 wire types. These prisms were tested at both ends, with a different embedment length assessed at each end. Thus, for each wire type and concrete release strength evaluated, a total of 4 tests were conducted for a total of 60 tests (5 wire types × 3 release strengths × 4 tested embedment lengths). Test results indicate that the concrete compressive strength at de-tensioning can have a direct impact on the ultimate flexural capacity of the members, and this has significant design implications for pretensioned concrete railroad ties. Results are discussed and recommendations made.


Sign in / Sign up

Export Citation Format

Share Document