scholarly journals Efficiency analysis of electric energy use in palm oil processing (case study Bandar Pulau)

Author(s):  
E Warman ◽  
MN Iqbal ◽  
F Fahmi
2019 ◽  
Vol 119 ◽  
pp. 00023
Author(s):  
Viviana Negro ◽  
Davide Mainero

Currently, ACEA utilises biogas obtained from the treatment of the organic fraction of municipal solid waste for thermal and electric energy recovery through endothermic engines (3 MW, in total). By 2020, the biogas produced at the site will no longer be used as a fuel for the combined heat and power units, but it is expected to feed a purification system in order to obtain a flow of biomethane to be injected into the natural gas network. This is part of the Italian strategy to achieve the Horizon 2020 European targets aimed at promoting the renewable production of transport fuels. In order to encourage sustainability and innovative prototype technologies, ACEA has also been involved in some European research projects, in particular for the conversion of biogas into other energy carriers. furthermore, ACEA ha recently built a flexible experimental platform that can used for the validation step of prototypes in an industrial field.


2012 ◽  
Vol 7 (1) ◽  
Author(s):  
Yanjin Liu ◽  
Giraldo Eugenio

Cultured bacteria addition is one of the technologies used for odor control and FOG (fat, oil, and grease) removal in wastewater collection systems. This study investigated the efficiency of bacterial addition on wastewater odor control by conducting a set of full scale trials in a 60,000 cubic meter per day system for a period of two years. The objectives of this study were: (i) to identify factors that could impact wastewater treatment plant (WWTP) operations due to the effect of bacterial addition in the collection system, (ii) to estimate/understand the level of those impacts, and (iii) to present some interesting findings from the completed case study. The plant operation data before and during the bacterial addition were reviewed. The application of the cultured bacteria presented in the study was found to have significant impacts on the operation of the WWTP in terms of influent biological oxygen demand (BOD) and total suspended solids (TSS) loading, primary settling, sludge production, energy use, dissolved sulfides concentration, and methane production.


Buildings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 230
Author(s):  
Hossein Omrany ◽  
Veronica Soebarto ◽  
Jian Zuo ◽  
Ruidong Chang

This paper aims to propose a comprehensive framework for a clear description of system boundary conditions in life cycle energy assessment (LCEA) analysis in order to promote the incorporation of embodied energy impacts into building energy-efficiency regulations (BEERs). The proposed framework was developed based on an extensive review of 66 studies representing 243 case studies in over 15 countries. The framework consists of six distinctive dimensions, i.e., temporal, physical, methodological, hypothetical, spatial, and functional. These dimensions encapsulate 15 components collectively. The proposed framework possesses two key characteristics; first, its application facilitates defining the conditions of a system boundary within a transparent context. This consequently leads to increasing reliability of obtained LCEA results for decision-making purposes since any particular conditions (e.g., truncation or assumption) considered in establishing the boundaries of a system under study can be revealed. Second, the use of a framework can also provide a meaningful basis for cross comparing cases within a global context. This characteristic can further result in identifying best practices for the design of buildings with low life cycle energy use performance. Furthermore, this paper applies the proposed framework to analyse the LCEA performance of a case study in Adelaide, Australia. Thereafter, the framework is utilised to cross compare the achieved LCEA results with a case study retrieved from literature in order to demonstrate the framework’s capacity for cross comparison. The results indicate the capability of the framework for maintaining transparency in establishing a system boundary in an LCEA analysis, as well as a standardised basis for cross comparing cases. This study also offers recommendations for policy makers in the building sector to incorporate embodied energy into BEERs.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 749
Author(s):  
John H. Scofield ◽  
Susannah Brodnitz ◽  
Jakob Cornell ◽  
Tian Liang ◽  
Thomas Scofield

In this work, we present results from the largest study of measured, whole-building energy performance for commercial LEED-certified buildings, using 2016 energy use data that were obtained for 4417 commercial office buildings (114 million m2) from municipal energy benchmarking disclosures for 10 major U.S. cities. The properties included 551 buildings (31 million m2) that we identified as LEED-certified. Annual energy use and greenhouse gas (GHG) emission were compared between LEED and non-LEED offices on a city-by-city basis and in aggregate. In aggregate, LEED offices demonstrated 11% site energy savings but only 7% savings in source energy and GHG emission. LEED offices saved 26% in non-electric energy but demonstrated no significant savings in electric energy. LEED savings in GHG and source energy increased to 10% when compared with newer, non-LEED offices. We also compared the measured energy savings for individual buildings with their projected savings, as determined by LEED points awarded for energy optimization. This analysis uncovered minimal correlation, i.e., an R2 < 1% for New Construction (NC) and Core and Shell (CS), and 8% for Existing Euildings (EB). The total measured site energy savings for LEED-NC and LEED-CS was 11% lower than projected while the total measured source energy savings for LEED-EB was 81% lower than projected. Only LEED offices certified at the gold level demonstrated statistically significant savings in source energy and greenhouse gas emissions as compared with non-LEED offices.


2021 ◽  
Vol 13 (9) ◽  
pp. 5234
Author(s):  
Mustafa S. Al-Tekreeti ◽  
Salwa M. Beheiry ◽  
Vian Ahmed

Numerous decision support systems have been developed to address the decision-making process in organizations. However, there are no developed mechanisms to track commitment down the line to the decisions made by corporate leaders. This paper is a portion of a study that establishes a framework for a comprehensive metric system to assess commitment to Sustainable Development (SD) decisions down the line in capital projects, and sets the groundwork for further development of performance indicators for SD outcomes. This ultimately leads to investigating the relationship between commitment to corporate decisions and better project performance in SD parameters. Hence, this study explores the literature to extract relevant parameters that reflect the degree of the project participants’ commitment to SD decisions and to develop commitment indicators. The study created then validated an index to track this commitment along the project stages: the Sustainable Development Commitment Tracking Tool (SDCTT). The SDCTT was tested on an infrastructure project case study. In this paper, techniques relevant to the first stage of projects (planning and definition) are presented. The SDCTT is the groundwork for the future development of performance indicators for SD outcomes, and within the postulated model should ultimately contribute towards reducing project waste, energy use, and carbon emissions.


Author(s):  
Julio Cezar Santos ◽  
Wagner Santos ◽  
Guilherme Cestaro ◽  
Marcio Zamboti Fortes ◽  
Henrique Henriques

AbstractThe growing demand for quality in the Energy Distribution Service, both by consumers and by regulatory agencies, obliges most distribution utilities to apply technologies that can be easily implemented and produce results in a short term horizon. The telecontrol technology is an essential tool every time it is necessary to fast restore the energy supply. This technology, which is completely supervised and controlled by the system operation center, allows the fast detection of a fault at a distance and switch an equipment without the aid of the operating crew, thus reducing the time that the power supply is unavailable. The present paper describes a Telecontrol Project, incorporated in an electric energy distribution utility in Brazil and compares the results in quality improvement with others usual investment actions, such as operating and maintenance procedures, laterals protection and network reinforcement. This paper shows, analyzing the results, that to improve the reliability indexes in a short time, when the company’s economic recovery is more important, the application of remotely controlled switch is more effective.


Sign in / Sign up

Export Citation Format

Share Document