scholarly journals A Comprehensive Framework for Standardising System Boundary Definition in Life Cycle Energy Assessments

Buildings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 230
Author(s):  
Hossein Omrany ◽  
Veronica Soebarto ◽  
Jian Zuo ◽  
Ruidong Chang

This paper aims to propose a comprehensive framework for a clear description of system boundary conditions in life cycle energy assessment (LCEA) analysis in order to promote the incorporation of embodied energy impacts into building energy-efficiency regulations (BEERs). The proposed framework was developed based on an extensive review of 66 studies representing 243 case studies in over 15 countries. The framework consists of six distinctive dimensions, i.e., temporal, physical, methodological, hypothetical, spatial, and functional. These dimensions encapsulate 15 components collectively. The proposed framework possesses two key characteristics; first, its application facilitates defining the conditions of a system boundary within a transparent context. This consequently leads to increasing reliability of obtained LCEA results for decision-making purposes since any particular conditions (e.g., truncation or assumption) considered in establishing the boundaries of a system under study can be revealed. Second, the use of a framework can also provide a meaningful basis for cross comparing cases within a global context. This characteristic can further result in identifying best practices for the design of buildings with low life cycle energy use performance. Furthermore, this paper applies the proposed framework to analyse the LCEA performance of a case study in Adelaide, Australia. Thereafter, the framework is utilised to cross compare the achieved LCEA results with a case study retrieved from literature in order to demonstrate the framework’s capacity for cross comparison. The results indicate the capability of the framework for maintaining transparency in establishing a system boundary in an LCEA analysis, as well as a standardised basis for cross comparing cases. This study also offers recommendations for policy makers in the building sector to incorporate embodied energy into BEERs.

2020 ◽  
Vol 12 (1) ◽  
pp. 351 ◽  
Author(s):  
Hossein Omrany ◽  
Veronica Soebarto ◽  
Ehsan Sharifi ◽  
Ali Soltani

Residential buildings are responsible for a considerable portion of energy consumption and greenhouse gas emissions worldwide. Correspondingly, many attempts have been made across the world to minimize energy consumption in this sector via regulations and building codes. The focus of these regulations has mainly been on reducing operational energy use, whereas the impacts of buildings’ embodied energy are frequently excluded. In recent years, there has been a growing interest in analyzing the energy performance of buildings via a life cycle energy assessment (LCEA) approach. The increasing amount of research has however caused the issue of a variation in results presented by LCEA studies, in which apparently similar case studies exhibited different results. This paper aims to identify the main sources of variation in LCEA studies by critically analyzing 26 studies representing 86 cases in 12 countries. The findings indicate that the current trend of LCEA application in residential buildings suffers from significant inaccuracy accruing from incomplete definitions of the system boundary, in tandem with the lack of consensus on measurements of operational and embodied energies. The findings call for a comprehensive framework through which system boundary definition for calculations of embodied and operational energies can be standardized.


2019 ◽  
Vol 887 ◽  
pp. 335-343
Author(s):  
Nazanin Moazzen ◽  
Mustafa Erkan Karaguler ◽  
Touraj Ashrafian

Energy efficiency has become a crucial part of human life, which has an adverse impact on the social and economic development of any country. In Turkey, it is a critical issue especially in the construction sector due to increase in the dependency on the fuel demands. The energy consumption, which is used during the life cycle of a building, is a huge amount affected by the energy demand for material and building construction, HVAC and lighting systems, maintenance, equipment, and demolition. In general, the Life Cycle Energy (LCE) needs of the building can be summarised as the operational and embodied energy together with the energy use for demolition and recycling processes.Besides, schools alone are responsible for about 15% of the total energy consumption of the commercial building sector. To reduce the energy use and CO2 emission, the operational and embodied energy of the buildings must be minimised. Overall, it seems that choosing proper architectural measures for the envelope and using low emitting material can be a logical step for reducing operational and embodied energy consumptions.This paper is concentrated on the operating and embodied energy consumptions resulting from the application of different architectural measures through the building envelope. It proposes an educational building with low CO2 emission and proper energy performance in Turkey. To illustrate the method of the approach, this contribution illustrates a case study, which was performed on a representative schoold building in Istanbul, Turkey. Energy used for HVAC and lighting in the operating phase and the energy used for the manufacture of the materials are the most significant parts of embodied energy in the LCE analyses. This case study building’s primary energy consumption was calculated with the help of dynamic simulation tools, EnergyPlus and DesignBuilder. Then, different architectural energy efficiency measures were applied to the envelope of the case study building. Then, the influence of proposed actions on LCE consumption and Life Cycle CO2 (LCCO2) emissions were assessed according to the Life Cycle Assessment (LCA) method.


Buildings ◽  
2018 ◽  
Vol 8 (8) ◽  
pp. 105 ◽  
Author(s):  
Nadia MIRABELLA ◽  
Martin RÖCK ◽  
Marcella Ruschi Mendes SAADE ◽  
Carolin SPIRINCKX ◽  
Marc BOSMANS ◽  
...  

Globally, the building sector is responsible for more than 40% of energy use and it contributes approximately 30% of the global Greenhouse Gas (GHG) emissions. This high contribution stimulates research and policies to reduce the operational energy use and related GHG emissions of buildings. However, the environmental impacts of buildings can extend wide beyond the operational phase, and the portion of impacts related to the embodied energy of the building becomes relatively more important in low energy buildings. Therefore, the goal of the research is gaining insights into the environmental impacts of various building strategies for energy efficiency requirements compared to the life cycle environmental impacts of the whole building. The goal is to detect and investigate existing trade-offs in current approaches and solutions proposed by the research community. A literature review is driven by six fundamental and specific research questions (RQs), and performed based on two main tasks: (i) selection of literature studies, and (ii) critical analysis of the selected studies in line with the RQs. A final sample of 59 papers and 178 case studies has been collected, and key criteria are systematically analysed in a matrix. The study reveals that the high heterogeneity of the case studies makes it difficult to compare these in a straightforward way, but it allows to provide an overview of current methodological challenges and research gaps. Furthermore, the most complete studies provide valuable insights in the environmental benefits of the identified energy performance strategies over the building life cycle, but also shows the risk of burden shifting if only operational energy use is focused on, or when a limited number of environmental impact categories are assessed.


Facilities ◽  
2014 ◽  
Vol 32 (3/4) ◽  
pp. 160-181 ◽  
Author(s):  
Manish K. Dixit ◽  
Charles H. Culp ◽  
Sarel Lavy ◽  
Jose Fernandez-Solis

Purpose – The recurrent embodied energy (REE) is the energy consumed in the maintenance, replacement and retrofit processes of a facility. The purpose of this paper was to analyze the relationship of REE with the service life and life cycle embodied energy. The amount of variation in the reported REE values is also determined and discussed. Design/methodology/approach – A qualitative approach that is known as the literature based discovery (LBD) was adopted. Existing literature was surveyed to gather case studies and to analyze the reported values of REE. Findings – The reported values of REE showed considerable variation across referred studies. It was also found that the reported REE values demonstrated a moderate positive correlation with the service life but a very strong positive correlation with the life cycle embodied energy of both the residential and commercial facilities. Research limitations/implications – This review paper pointed out the importance of the maintenance and replacement processes in reducing the life cycle energy use in a facility. Future research could focus on performing case studies to evaluate this relationship. Practical implications – The findings highlight the significance of REE in reducing the life cycle energy impacts of a facility. As facility managers routinely deal with maintenance and replacement processes, they hold an important responsibility of reducing the life cycle energy. Originality/value – The findings of the paper would motivate the facilities management professionals to prefer long service life materials and components during the postconstruction phases of a built facility.


2021 ◽  
Author(s):  
◽  
Nicolas Perez Fernandez

<p>This thesis studies the influence of construction materials on the life-cycle energy consumption and carbon dioxide (CO2) emissions of medium sized low energy consumption commercial buildings. When describing buildings by materials, there is a tendency to label them according to the main structural material used. However, the vast majority of commercial buildings use a large number of materials. Hence it is not clear which materials or combinations of materials can achieve the best performance, in terms of lifecycle energy use and CO2 emissions. The buildings analysed here were based on an actual six-storey 4250m2 (gross floor area) building, with a mixed-mode ventilation system, currently under construction at the University of Canterbury in Christchurch. While the actual building is being constructed in concrete, the author has designed two further versions in which the structures and finishes are predominantly steel or timber. Despite having different structural materials, large quantities of finishes materials are common to all three buildings; large glazed curtain walls and sun louvers, stairs balustrade and most of the offices internal finishes. A fourth building was also produced in which all possible common finishes' of the timber building were replaced by timber components. This building is labelled as Timber-plus and was included to assess the difference of the three initial 'common finishes' buildings against a building that might be expected to have a low or even negative total embodied CO2 emission in structure and finishes. In order to highlight the influence of materials, each building was designed to have a similar indoor climate with roughly the same amount of operational energy for heating and cooling over its full life. Both energy use and CO2 emissions have been assessed over three main stages in the life (and potential environmental impact) of a building: initial production of the building materials (initial embodied energy and initial embodied CO2 emissions); operation of the building (mainly in terms of its energy use); and the refurbishment and maintenance of the building materials over the building's effective life (recurrent embodied energy and CO2 emissions). Calculation of embodied energy and embodied CO2 emissions are based on materials' estimates undertaken by a Quantity Surveyor. DesignBuilder software was used to estimate whole life-cycle energy used and CO2 emitted in the operation of the buildings over a period of 60 years. Two different methods for embodied energy and embodied CO2 calculation were applied to the four buildings. The first method was by multiplying the volume of each material in the schedule calculated by the Quantity Surveyor by the New Zealand specific coefficients of embodied energy and embodied CO2 produced by Andrew Alcorn (2003). The second method was analysing the same schedule of materials with GaBi professional LCA software. Materials' inventories in GaBi are average German industry data collected by PE Europe between 1996 and 2004 (Alcorn, 2003; Nebel & Love, 2008). The energy results of the thesis show that when using the Alcorn coefficients, the total embodied energy (initial plus recurrent embodied energy) averaged 23% and operating energy consumption averaged 77% of the total life-cycle energy consumption for the four buildings. Using the GaBi coefficients, total embodied energy averaged 19% and operating energy consumption averaged 81% of the total life-cycle energy consumption of the four buildings. Using the Alcorn coefficients, the difference between the highest (steel building) and lowest (timber-plus building) life-cycle energy consumption represents a 22% increment of the highest over the lowest. Using the GaBi coefficients, the difference between the lowest (timber-plus building) and the highest (timber building) life-cycle energy consumption represents a 15% increment of the highest over the lowest. The CO2 results shows that when using the Alcorn coefficients, the total embodied CO2 emissions averaged 7% and operating CO2 emissions averaged 93%. Using the GaBi coefficients, total embodied CO2 emissions averaged 16% and operating CO2 emissions averaged 84% of the life-cycle CO2 emissions of the four buildings. Using the Alcorn coefficients, the difference between the highest (steel building) and lowest (timber-plus building) life-cycle CO2 emissions represents a 27% increment of the highest over the lower. Using the GaBi coefficients, the difference between the highest (timber building) and the lowest (timber-plus building) lifecycle CO2 emissions represents a 9% increment of the highest over the lowest. While for the case of embodied energy the Alcorn results averaged 32% higher than the GaBi, in the case of embodied CO2 the Alcorn results averaged 62% lower than the GaBi. Major differences in the results produced when using the two different sets of embodied energy and CO2 coefficients are due mainly to their different approaches to the CO2 sequestration in timber materials. While the Alcorn coefficients account for the CO2 sequestration of timber materials, the GaBi coefficients do not. This is particularly noteworthy as the CO2 sequestration of timber has been neglected in previous research. It was established that embodied energy can significantly influence the life-cycle energy consumption and CO2 emissions of contemporary low energy buildings. Using the Alcorn coefficients, the steel building embodied the equivalent of 27 years of operating energy consumption and 12 years of operating CO2 emissions. At the other end of the spectrum the timber-plus building embodied the equivalent of 11 years of operating energy consumption and has stored the equivalent of 3.6 years of operating CO2 emissions. Using the GaBi coefficients, the steel building embodied the equivalent of 19 years of operating energy consumption and 14 years of operating CO2 emissions, while the timber-plus building embodied the equivalent of 8 years of operating energy consumption and 8 years of operating CO2 emissions. These findings are of significance, for example, in the assessment and weighting of the embodied energy and embodied CO2 components of building sustainable rating tools.</p>


2020 ◽  
Vol 28 (1) ◽  
pp. 20-24
Author(s):  
Martin Jamnický ◽  
Roman Rabenseifer

AbstractThis article proposes to contribute to the discussion on environmental product declarations for buildings. Using a simple life-cycle analysis of a low-energy detached house and CO2-equivalent emissions as a comparative unit, the case study presented illustrates the problems with the initial input data related to embodied energy and a definition of the criteria for an assessment of the environmental quality of buildings. The actual case study compares the expected energy demand of a detached house in the course of its service life and the energy input (embodied energy) necessary for its assembly and for the manufacture of the individual building products. The operation of the building during its service life is described using a computer-aided building performance simulation. The input data related to the embodied energy are based on information from classical works on life cycle analyses. In addition, the article discusses the limits of building envelope improvements in terms of the thickness of thermal insulation and also stresses the increasing significance of embodied energy in the environmental assessment of buildings.


2014 ◽  
Vol 32 (1) ◽  
pp. 49-60 ◽  
Author(s):  
Zaid Alwan ◽  
Paul Jones

Purpose – The construction industry has focused on operational and embodied energy of buildings as a way of becoming more sustainable, however, with more emphasis on the former. The purpose of this paper is to highlight the impact that embodied energy of construction materials can have on the decision making when designing buildings, and ultimately on the environment. This is an important aspect that has often been overlooked when calculating a building's carbon footprint; and its inclusion this approach presents a more holistic life cycle assessment. Design/methodology/approach – A building project was chosen that is currently being designed; the design team for the project have been tasked by the client to make the facility exemplary in terms of its sustainability. This building has a limited construction palette; therefore the embodied energy component can be accurately calculated. The authors of this paper are also part of the design team for the building so they have full access to Building Information Modelling (BIM) models and production information. An inventory of materials was obtained for the building and embodied energy coefficients applied to assess the key building components. The total operational energy was identified using benchmarking to produce a carbon footprint for the facility. Findings – The results indicate that while operational energy is more significant over the long term, the embodied energy of key materials should not be ignored, and is likely to be a bigger proportion of the total carbon in a low carbon building. The components with high embodied energy have also been identified. The design team have responded to this by altering the design to significantly reduce the embodied energy within these key components – and thus make the building far more sustainable in this regard. Research limitations/implications – It may be is a challenge to create components inventories for whole buildings or for refurbishments. However, a potential future approach for is application may be to use a BIM model to simplify this process by imbedding embodied energy inventories within the software, as part of the BIM menus. Originality/value – This case study identifies the importance of considering carbon use during the whole-life cycle of buildings, as well as highlighting the use of carbon offsetting. The paper presents an original approach to the research by using a “live” building as a case study with a focus on the embodied energy of each component of the scheme. The operational energy is also being calculated, the combined data are currently informing the design approach for the building. As part of the analysis, the building was modelled in BIM software.


2016 ◽  
Vol 861 ◽  
pp. 601-608 ◽  
Author(s):  
Daniela Mackova ◽  
Marcela Spisakova ◽  
Mária Kozlovská ◽  
Jozef Svajlenka

Currently, we are witnessing the significant impact of industrial activity on the environment. A recent study shows that construction is the third largest industry sector in terms of environmental pollution. One option to reduce these negative effects is environmental assessment of buildings, as well as the used building materials. One of the most comprehensive environmental assessment methods is LCA (Life Cycle Assessment), which includes the assessment of impacts within mode ”Cradle-to-gate” which is focused on assessment of a partial product life cycle from resource extraction (cradle) to the factory gate (i.e., before it is transported to the consumer). The aim of this paper is a comparison of the environmental impact of selected material variants applied within modern methods of construction. The comparison will be processed through the results of the case study containing three material variants of family houses construction in term of three selected parameters - embodied energy, global warming potential and acidification potential.


2019 ◽  
Vol 111 ◽  
pp. 03028
Author(s):  
Nazanin Moazzen ◽  
Mustafa Erkan Karagüler ◽  
Touraj Ashrafian

Energy efficiency of existing buildings is a concept to manage and restrain the growth in energy consumption and one of the crucial issues due to the magnitude of the sector. Educational buildings are in charge of about 15% of the total energy consumption of the non-residential building sector. However, not only operational but also embodied energy of a building should be reduced to get the overall benefits of energy efficiency, where, using energy efficient architectural measures and low emitting materials during every retrofit action can be a logical step. The majority of buildings in Turkey and EU was built earlier than the development of the energy efficiency in the construction sector, hence, without energy retrofit, consume an enormous amount of energy that can be averted significantly by the implementation of some even not advanced retrofit measures. Furthermore, demolishing of a building to construct a new one is not a rational approach concerning cost, time and environmental pollution. The study has been focused on the impact assessment of the various architectural scenarios of energy efficiency upgrading on the Life Cycle Energy Consumption (LCEC) and Life Cycle CO2 (LCCO2) emission. Within the scope of the study, a primary school building is selected to be analysed. Through analysis, the total embodied and operational energy use and CO2 emission regarding the life cycle phase of the building is quantitatively defined and investigated in the framework of life cycle inventory. The paper concentrates on the operation and embodied energy consumption arising from the application of a variety of measures on the building envelope. An educational building with low LCCO2 emissions and LCEC in Turkey is proposed. To exemplify the approach, contributions are applied to a case study in Istanbul as a representative school building. The primary energy consumption of the case study building is calculated with a dynamic simulation tool, EnergyPlus. Afterwards, a sort of architectural energy efficient measures is implemented in the envelope while the lighting and mechanical systems remain constant. The energy used in the production and transportation of materials, which are the significant parts of the embodied energy, are taken into account as well.


Sign in / Sign up

Export Citation Format

Share Document