scholarly journals Developing optimal ventilation system for a pasta production workshop using mathematical model

Author(s):  
L G Starkova ◽  
M S Shcherbak ◽  
V S Indykov
2018 ◽  
Vol 38 (3) ◽  
pp. 321-327
Author(s):  
Jingfu Jia ◽  
Manjin Hao ◽  
Jianhua Zhao

Forced or natural ventilation is the most common measure of frost heave protection for refrigerated warehouse floor. To optimize air velocity for the underfloor forced ventilation system of refrigerated warehouse, a steady state three-dimensional mathematical model of heat transfer is set up in this paper. The temperature fields of this system are simulated and calculated by CFD software PHOENICS under different air velocity, 1.5m/s, 2.5m/s or 3.5m/s. The results show that the optimized air velocity is 1.5m/s when the tube spacing is 1.5m.


2018 ◽  
Vol 193 ◽  
pp. 03007 ◽  
Author(s):  
Sergei Kolodyazhniy ◽  
Vladimir Kozlov

Using an integral mathematical model of a fire considering the assumptions typical of a starting stage of a fire, analytical dependencies were obtained for determining the time of reaching a critical value of the density of a smoke screen in a premises with a fire epicenter and adjoining premises. By means of analytical formulas for determining critical evacuation time intervals based on visibility loss, table values for different parameters that are included in the original equations were obtained. Simple engineering analytical solutions that describe the dynamics of smoke formation in premises in case of a fire when used in a certain combination are presented. The obtained dependencies allow one to identify the critical time of evacuation with no use of special PC software as well as to obtain original data without calculating an anti-smoke ventilation system.


2014 ◽  
Vol 1070-1072 ◽  
pp. 1216-1221
Author(s):  
Dong Xiang ◽  
Hao Xiong ◽  
Ning Bo Liu ◽  
Qiang Wu ◽  
Guang Wei Meng

This paper takes the ship air-cooled AC generator with the radial ventilation system for example, establishes the mathematical model of a generator core and winding temperature by using an equivalent thermal circuit method and the temperature calculation method based on the operating parameters, analyzes the transfer function between the generator stator winding temperature rise and the phase voltage, phase current and reactive power, and finally verifies validity of the mathematical model by the experiment.


Author(s):  
О. Симбирев ◽  
O. Simbirev

The main problem highlighted in the article is the deviation of the microclimate parameters from the standard values due to the improper organization of airflow in the residential rooms of apartment buildings. The objective is to obtain a working mathematical model of the natural ventilation system, its study for optimization or modernization. The analysis of the normative literature, scientific works of domestic and foreign scientists, developments in the field of natural ventilation and ventilation of residential buildings is carried out. A mathematical model of air exchange of a residential room with convection is presented and analyzed. The flow rate and air temperature, the temperature on the surface of the heater are set as boundary conditions when creating a mathematical model. The features and regularities of airflow distribution in the room obtained as a result of mathematical modeling are revealed. The distributions of air velocity in the room are given. Difficulties of the organization of effective natural inflow of air and the problems with design of valves of infiltration are designated. Technical solutions aimed at improving the quality of indoor microclimate and energy saving are proposed.


Author(s):  
Jesús Calderón ◽  
Carlos Rincón ◽  
Bray Agreda ◽  
Juan José Jiménez

A mechanical ventilation system is a big support for breathing complications, in which an external solution is quite necessary to keep oxygen compensation in the patients. Its knowledge is well widespread and different equipment has been developed. However, they are very expensive and their quantity in medical centers is not sufficient, especially in Peru. Hence, it has been required to develop new methods to provide oxygen by a low cost equipment; Protofy, a research group from Spain, designed one of the first low cost mechanical ventilation systems which was medically validated by its government. In this sense, a redesign of the mechanical ventilation system was carried out according to the local requirements and available technology, a different airbag resuscitator with different properties and geometry, but maintaining its working concept based on a cam compression mechanism. Sensors and a display were added to improve the performance with a control algorithm for the rotation frequency and to show the ventilation curves over time to the medical staff. It was necessary to develop a mathematical model to relate the behavior between ventilation curves for a patient and physical variables of the design, especially in the epidemic COVID 19, that many countries are dealing with at the time research is being conducted. The mechanical ventilation system was redesigned, fabricated, and tested measuring its ventilation curves over time. Results indicate that this redesign provides a sturdy equipment able to work during a longer lifetime than the original. The replicability of the ventilation curves behavior is assured, while the mechanism dimensions are adapted for a particular airbag resuscitator. The mathematical model of the whole system can predict satisfactorily the ventilation curves over time and was used to provide the air pressure, volume, and flow as a function of the rotation angle measured by sensors.


2016 ◽  
Vol 2016 ◽  
pp. 1-13 ◽  
Author(s):  
Dongkai Shen ◽  
Qian Zhang ◽  
Yan Shi

In recent studies on the dynamic characteristics of ventilation system, it was considered that human had only one lung, and the coupling effect of double lungs on the air flow can not be illustrated, which has been in regard to be vital to life support of patients. In this article, to illustrate coupling effect of double lungs on flow dynamics of mechanical ventilation system, a mathematical model of a mechanical ventilation system, which consists of double lungs and a bi-level positive airway pressure (BIPAP) controlled ventilator, was proposed. To verify the mathematical model, a prototype of BIPAP system with a double-lung simulators and a BIPAP ventilator was set up for experimental study. Lastly, the study on the influences of key parameters of BIPAP system on dynamic characteristics was carried out. The study can be referred to in the development of research on BIPAP ventilation treatment and real respiratory diagnostics.


2015 ◽  
Vol 15 (03) ◽  
pp. 1550032 ◽  
Author(s):  
YAN SHI ◽  
JINGLONG NIU ◽  
MAOLIN CAI ◽  
WEIQING XU

To improve the efficiency and safety of secretion clearance, a novel ventilator (SC ventilator) with an automatic secretion clearance function is proposed. To lay a foundation for the optimization of the SC ventilator, the basic mathematical model of the ventilation system is derived. By selecting the appropriate reference values, the basic mathematical model is transformed to a dimensionless expression for simulation. Through the experimental and simulation study on the SC ventilation system, it can be concluded that: firstly, the mathematical model is proved to be authentic and reliable. Secondly, the influences of the three key parameters on the dynamics of the SC ventilation system are carried out. Last, to guarantee the pressure in the lung is higher than the expiratory positive airway pressure, the dimensionless minimum pressure in the flexible tube should be set higher than 0.9164, the dimensionless suction pressure should be set higher than 0.79.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Yan Shi ◽  
Shuai Ren ◽  
Maolin Cai ◽  
Weiqing Xu

Secretions of ventilated patients must be cleared efficiently and timely; to improve the secretion clearance efficiency of an insufflation-exsufflation device (IL-IE device) and lay a foundation for the optimization of the IL-IE device, a mathematical model of the ventilation system with the IL-IE device is set up. Through the experimental and simulation research on the ventilation system, it can be concluded that, firstly, the mathematical model is proved to be authentic and reliable. Secondly, with the deposition of secretion or an increase in the respiratory compliance, the peak exsufflation airflow may be reduced. Thirdly, with a decrease in the suction pressure, the peak exsufflation airflow of the ventilated lung may rise proportionally, but the minimum pressure in the ventilated lung may descend proportionally. To improve the efficiency of the secretion clearance but not to injure the ventilated patient, the suction pressure can be elevated properly. Last, increasing the inspiratory positive airway pressure (IPAP) is a method to improve the secretion clearance efficiency. This research lays a foundation for improving the secretion clearance efficiency of the IL-IE device.