scholarly journals Effects of Implantable Cardioverter Defibrillator Implantation and Shock Application on Biochemical Markers of Myocardial Damage

2001 ◽  
Vol 47 (3) ◽  
pp. 459-463 ◽  
Author(s):  
Thomas Schlüter ◽  
Hannsjörg Baum ◽  
Andreas Plewan ◽  
Dieter Neumeier

Abstract Background: Implantable cardioverter defibrillator (ICD) implantation is a common approach in patients at high risk of sudden cardiac death. To check for normal function, it is necessary to test the ICD. For this purpose, repetitive induction and termination of ventricular fibrillation by direct current shocks is required. This may lead to minor myocardial damage. Cardiac troponin T (cTnT) and I (cTnI) are specific markers for the detection of myocardial injury. Because these proteins usually are undetectable in healthy individuals, they are excellent markers for detecting minimal myocardial damage. The objective of this study was to evaluate the effect of defibrillation of induced ventricular fibrillation on markers of myocardial damage. Methods: This study included 14 patients who underwent ICD implantation and intraoperative testing. We measured cTnT, cTnI, creatine kinase MB (CK-MB) mass, CK activity, and myoglobin before and at definite times after intraoperative shock application. Results: Depending on the effectiveness of shocks and the energy applied, the cardiac-specific markers cTnT and cTnI, as well as CK-MB mass, showed a significant increase compared with the baseline value before testing and peaked for the most part 4 h after shock application. In contrast, the increases in CK activity and myoglobin were predominantly detectable in patients who received additional external shocks. Conclusions: ICD implantation and testing leads to a short release of cardiac markers into the circulation. This release seems to be of cytoplasmic origin and depends on the number and effectiveness of the shocks applied.

2002 ◽  
Vol 9 (2) ◽  
pp. 105-109 ◽  
Author(s):  
CK Shum ◽  
ML Tse ◽  
FL Lau ◽  
WK Chan

A healthy 28-year-old man presented with multiple brief episodes of convulsion. He was found to have ventricular fibrillation which required defibrillation in the emergency department. After exclusion of organic heart diseases, Brugada syndrome was diagnosed and required implantable cardioverter defibrillator (ICD) implantation. The case emphasized the recognition of malignant cardiac dysrrhythmias as a cause for seizures. The management in the emergency department was discussed.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
J De Juan Baguda ◽  
J.J Gavira Gomez ◽  
M Pachon Iglesias ◽  
L Pena Conde ◽  
J.M Rubin Lopez ◽  
...  

Abstract Background The HeartLogic algorithm combines multiple implantable cardioverter-defibrillator (ICD)-based sensors into an index for prediction of impending heart failure (HF) decompensation. In patients with ICD and cardiac resynchronization therapy ICD remotely monitored at 13 Spanish centers, we analyzed the association between clinical events and HeartLogic alerts and we described the use of the algorithm for the remote management of HF. Methods The association between clinical events and HeartLogic alerts was studied in the blinded phase (from ICD implantation to alert activation – no clinical actions taken in response to alerts) and in the following active phase (after alert activation – clinicians automatically notified in case of alert). Results We enrolled a total of 215 patients (67±13 years old, 77% male, 53% with ischemic cardiomyopathy) with ICD (19%) or CRT-D (81%). The median duration of the blinded phase was 8 [3–12] months. In this phase, the HeartLogic index crossed the threshold value (set by default to 16) 34 times in 20 patients. HeartLogic alerts were associated with 6 HF hospitalizations and 5 unplanned in-office visits for HF. Five additional HeartLogic threshold crossings were not associated with overt HF events, but occurred at the time of changes in drug therapy or of other clinical events. The rate of unexplained alerts was 0.25 alert-patient/year. The median time spent in alert was longer in the case of HF hospitalizations than of in-office visits (75 [min-max: 30–155] days versus 39 [min-max: 5–105] days). The maximum HeartLogic index value was 38±15 in the case of hospitalizations and 24±7 in that of minor HF events. The median duration of the following active phase was 5 [2–10] months. After HeartLogic activation, 40 alerts were reported in 26 patients. Twenty-seven (68%) alerts were associated with multiple HF- or non-HF related conditions or changes in prescribed HF therapy. Multiple actions were triggered by these alerts: HF hospitalization (4), unscheduled in-office visits (8), diuretics increase (8), change in other cardiovascular drugs (5), device reprogramming (2), atrial fibrillation ablation (1), patient education on therapy adherence (2). The rate of unexplained alerts not followed by any clinical action was 0.13 alert-patient/year. These alerts were managed remotely (device data review and phone contact), except for one alert that generated an unscheduled in-office visit. Conclusions HeartLogic index was frequently associated with HF-related clinical events. The activation of the associated alert allowed to remotely detect relevant clinical conditions and to implement clinical actions. The rate of unexplained alerts was low, and the work required in order to exclude any impending decompensation did not constitute a significant burden for the centers. Funding Acknowledgement Type of funding source: None


Author(s):  
Victor Nauffal ◽  
Peter Marstrand ◽  
Larry Han ◽  
Victoria N Parikh ◽  
Adam S Helms ◽  
...  

Abstract Aims  Risk stratification algorithms for sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HCM) and regional differences in clinical practice have evolved over time. We sought to compare primary prevention implantable cardioverter defibrillator (ICD) implantation rates and associated clinical outcomes in US vs. non-US tertiary HCM centres within the international Sarcomeric Human Cardiomyopathy Registry. Methods and results We included patients with HCM enrolled from eight US sites (n = 2650) and five non-US (n = 2660) sites and used multivariable Cox-proportional hazards models to compare outcomes between sites. Primary prevention ICD implantation rates in US sites were two-fold higher than non-US sites (hazard ratio (HR) 2.27 [1.89–2.74]), including in individuals deemed at high 5-year SCD risk (≥6%) based on the HCM risk-SCD score (HR 3.27 [1.76–6.05]). US ICD recipients also had fewer traditional SCD risk factors. Among ICD recipients, rates of appropriate ICD therapy were significantly lower in US vs. non-US sites (HR 0.52 [0.28–0.97]). No significant difference was identified in the incidence of SCD/resuscitated cardiac arrest among non-recipients of ICDs in US vs. non-US sites (HR 1.21 [0.74–1.97]). Conclusion  Primary prevention ICDs are implanted more frequently in patients with HCM in US vs. non-US sites across the spectrum of SCD risk. There was a lower rate of appropriate ICD therapy in US sites, consistent with a lower-risk population, and no significant difference in SCD in US vs. non-US patients who did not receive an ICD. Further studies are needed to understand what drives malignant arrhythmias, optimize ICD allocation, and examine the impact of different ICD utilization strategies on long-term outcomes in HCM.


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
Atsushi Takahashi ◽  
Tsuyoshi Shiga ◽  
Daigo Yagishita ◽  
Keisuke Futagawa ◽  
Naoki Serizawa ◽  
...  

Purpose: Implantable Cardioverter Defibrillator (ICD) prevents sudden cardiac death in high risk patients with heart failure (HF). Worsening renal function (WRF) is associated with mortality in patients with myocardial infarction or HF, but its effect on lethal arrhythmia is unknown. We evaluated the influence of WRF on the occurrence of arrhythmic events in patients with nonischemic HF and ICD. Methods: A total of 286 nonischemic HF patients who underwent ICD implantation between 1990 and 2007 were studied. Estimated Glomerular Filtration Rate (eGFR) was calculated using the Modification of Diet in Renal Disease. Renal dysfunction was defined as eGFR <60mL/min/1.73m 2 and WRF was defined as 15mL/min/1.73m 2 per year. Differences in arrhythmia recurrences according to the eGFR and WRF were compared by Kaplan-Meier survival curves. Results: During a mean follow-up time of 2.2+/−1.0 years, 94 (33%) of 286 patients (mean age; 57+/−15 years, 72% male) experienced appropriate ICD shock therapy. There was a significantly higher cumulative rate of appropriate ICD shock therapy (p<0.05) and electrical storm (p<0.05) in patients with renal dysfunction than others. The patients with renal dysfunction at baseline experience WRF more frequently than other patients (53% vs. 23%, respectively, p<0.01). After correcting for age, sex, left ventricular ejection fraction (LVEF), indication for ICD implantation, and use of beta-blockers in a Cox regression model, WRF was still an independent predictor of the time to first appropriate shock (HR 2.21, 95% CI 1.32–3.69, p<0.05) and electrical storm (HR 2.22, 95% CI 1.19 – 4.13, p<0.05). The result of subgroup analysis of 147 patients with low LVEF (LVEF<35%) indicated that the patients with WRF experienced electrical storms more frequently (p<0.05). Conclusion: WRF is associated with increased rate of arrhythmic event in nonischemic HF patients. Especially, those patients with low LVEF and WRF experience more frequent ICD shocks.


Author(s):  

Dilated cardiomyopathy (DCM) is a disease characterised as left ventricular (LV) or biventricular dilatation with impaired systolic function. Regardless of underlying cause patients with DCM have a propensity to ventricular arrhythmias and sudden cardiac death. Implantable Cardioverter Defibrillator (ICD) implantation for these patients results in significant reduction of sudden cardiac death [1-3]. ICD devices may be limited by right ventricle (RV) sensing dysfunction with low RV sensing amplitude. We present a clinical case of patient with DCM, implanted ICD and low R wave sensing on RV lead.


2021 ◽  
pp. 1-3
Author(s):  
Sezen Gulumser Sisko ◽  
Hasan Candas Kafali ◽  
Yakup Ergul

Abstract We report a patient with long QT syndrome who received an inappropriate implantable cardioverter-defibrillator shock due to electrical interference from a refrigerator. This electrical interference was mistakenly detected as an episode of ventricular fibrillation and ended with an inappropriate delivery of shock without any warning symptoms before.