scholarly journals Kinetic Spectrophotometric Method for the Determination of Ranitidine and Nizatidine in Pharmaceuticals

2002 ◽  
Vol 85 (6) ◽  
pp. 1316-1323 ◽  
Author(s):  
Mohamed I Walash ◽  
Fathalla Belal ◽  
Fawzia Ibrahim ◽  
Mohamed Hefnawy ◽  
Manal Eid

Abstract An accurate and simple kinetic method is described for the determination of ranitidine and nizatidine in pure form and in pharmaceuticals. The method is based on the reaction of the compounds with 7-chloro-4-nitrobenz-2-oxa-1,3-diazole in pH 7.4 borate buffer at 60°C for a fixed time of 25 min for both compounds. The absorbance of the reaction product is measured at 495 nm for ranitidine and nizatidine. Calibration graphs were linear over the concentration range of 2–20 μg/mL, with limits of detection of 0.13 (3.7 × 10−7M) and 0.25 μg/mL (7.5 × 10−7M) for ranitidine and nizatidine, respectively. The proposed method was applied successfully to the determination of ranitidine in tablets and ampoules with average recoveries of 100.26 ± 0.69 and 100.29 ± 0.59%, respectively, and to the determination of nizatidine in capsules with an average recovery of 104.26 ± 0.44%. The results obtained are in good agreement with those obtained by the other methods used for comparison. A proposal of the reaction pathway is also presented.

2018 ◽  
Vol 39 (4) ◽  
pp. 49
Author(s):  
Halil İbrahim Ulusoy ◽  
Ramazan Gürkan

A novel sensitive and relatively selective kinetic method is presented for the determination of V(V), based on its catalytic effect on the oxidation reaction of Ponceau Xylydine by potassium bromate in presence of 5-sulfosalicylic acid (SSA) as activator. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of Ponceau Xylydine at 640 nm between 0.5 to 7 min (the fixed time method) in H3PO4 medium at 25oC. The effect of various parameters such as concentrations of H3PO4, SSA, bromate and Ponceau Xylydine, temperature and ionic strength on the rate of net reaction were studied. The method is free from most interferences, especially from large amounts of V(IV). The decrease in absorbance is proportional to the concentration of V(V) over the entire concentration range tested (1–15 ng mL−1) with a detection limit of 0.46 ng mL–1 (according to statistical 3Sblank/k criterion) and a coefficient of variation (CV) of 1.8% (for ten replicate measurement at 95% confidence level).The proposed method suffers few interferences such as Cr(VI) and Hg(II) ions. The method was successfully applied to the determination of V(V) in tap water, drinking water, bottled mineralwater samples and a certified standard reference material such as SRM-1640 with satisfactory results. The vanadium contents of water samples were also determined by FAAS for a comparison.The recovery of spiked vanadium(V) was found to be quantitative and the reproducibility was satisfactory. It was observed that the results of the SRM 1640 were in good agreement with the certified value.


2012 ◽  
Vol 602-604 ◽  
pp. 1289-1293 ◽  
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

A spectrophotometric method was developed for the determination of trace Ru (III) is described, based on its catalytic effect of Ru (III) on the oxidation of dibromo caboxy arsenazo (DBCAA) by bromate in acidic and micellar medium at 100 °C. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of the catalytic reaction of DBCAA at 530 nm with a fixed-time method. The calibration curve for the recommended method was linear in the concentration range over 0.037–1.0 µg/L and the detection limit of the method for Ru (III) was 0.011 µg/L. The method was applied to the determination of Ru (III) in some ores and metallurgy products. The results are in good agreement with the recommend values with the relative standard deviation of 2.6 %–3.8 % and the recovery of 97.2 %–104.3 %.


BMC Chemistry ◽  
2021 ◽  
Vol 15 (1) ◽  
Author(s):  
Shaza Affas ◽  
Amir Alhaj Sakur

Abstract Background simple, sensitive, free of organic solvents, kinetic spectrophotometric method has been developed for the determination of Clindamycin Hydrochloride, both in pure form and Capsules. Method is based on reaction of Clindamycin with potassium iodide and potassium iodate in an aqueous medium at (25 ± 2 °C) to produce yellow-coloured tri iodide ions (I3−). The reaction is followed spectrophotometrically by measuring the absorbance at wavelength 350 nm during 40 min. Results the effects of analytical parameters on reported kinetic methods were investigated. Under the optimized conditions, the initial rate and fixed time (at 10 min) methods were used for constructing the calibration graphs. The graphs were linear in concentration ranges 1–20 μg ml−1 with limit of detection of 0.12 and 0.22 μg ml−1for the initial rate and fixed time methods, respectively. The results were satisfactory and the analytical performance for both methods was validated. Conclusion The proposed methods have been applied to determine the components in capsules with an average recovery of 98.25–102.00% and the results are in good agreement with those found by the reference method.


Author(s):  
Mouhammed Khateeb ◽  
Basheer Elias ◽  
Fatema Al Rahal

A simple and sensitive kinetic spectrophotometric method has been developed for the determination of folic acid (FA) in bulk and pharmaceutical Formulations. The method is based on the oxidation of FA by Fe (III) in sulfuric acid medium. Fe (III) subsequently reduces to Fe (II) which is coupled with potassium ferricyanide to form Prussian blue. The reaction is followed spectrophotometrically by measuring the increase in absorbance at λmax 725 nm. The rate data and fixed time methods were adopted for constructing the calibration curves. The linearity range was found to be 1–20 μg mL-1 for each method. The correlation coefficient was 0.9978 and 0.9993, and LOD was found to be 0.91 and 0.09 μg mL-1 for rate data and fixed time methods, respectively. The proposed method has been successfully applied to the determination of FA in formulations with no interference from the excipients. Statical comparison of the results shows that there is no significant difference between the proposed and pharmacopoeial methods


2010 ◽  
Vol 7 (4) ◽  
pp. 1612-1620 ◽  
Author(s):  
M. Keyvanfard ◽  
N. Abedi

A new, simple, sensitive and selective kinetic spectrophotometric method was developed for the determination of ultra trace amounts of vanadium(V). The method is based on the catalytic effect of vanadium(V) on the oxidation of malachite green oxalate (MG) by bromate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of malachite green oxalate (MG) at 625 nm with a fixed-time method. The decrease in the absorbance of MG is proportional to the concentration of vanadium(V) in the range of 1-100 ng/mL with a fixed time of 0.5-2 min from the initiation of the reaction. The limit of detection is 0.71 ng/mL of vanadium(V). The relative standard deviation for the determination of 5, 30, 50 ng/mL of vanadium(V) was2.5% 2.6%, 2.4% and respectively. The method was applied to the determination of vanadium(V) in water samples.


2009 ◽  
Vol 74 (8-9) ◽  
pp. 977-984
Author(s):  
Sofija Rancic ◽  
Snezana Nikolic-Mandic

A new reaction was suggested and a new kinetic method was elaborated for determination of Bi(III) in solution, based on its catalytic effect on the oxidation of phenyl-fluorone (PF) by hydrogen peroxide in ammonia buffer. By application of spectrophotometric technique, a limit of quantification (LQ) of 128 ng cm-3 was reached, and the limit of detection (LD) of 37 ng cm-3 was obtained, where LQ was defined as the ratio signal: noise = 10:1 and LD was defined as signal 3:1 against the blank. The RSD value was found to be in the range 2.8-4.8 % for the investigated concentration range of Bi(III). The influence of some ions upon the reaction rate was tested. The method was confirmed by determining Bi(III) in a stomach ulcer drug ('Bicit HP', Hemofarm A.D.). The obtained results were compared to those obtained by AAS and good agreement of results was obtained.


2012 ◽  
Vol 204-208 ◽  
pp. 4067-4070 ◽  
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

A simple kinetic spectrophotometric method was developed for the determination of trace amounts of Ru (III). The method is based on the reduction of spadns by sodium hypophosphite (NaH2PO2) in micellar media. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of spadns at 515 nm with a fixed-time method. The decrease in the absorbance of spadns is proportional to the concentration of Ru (III) in the range 0.40–10.0 μg/L with a fixed time of 2.5–7.0 min from the initiation of the reaction. The limit of detection is 0.12 μg/L Ru (III). The relative standard deviation for the determination of 0.10 and 0.20 μg/25mL Ru (III) was 2.3 % and 2.0 %, respectively. The method was applied to the determination of Ru (III) in some ores and metallurgy products.


2012 ◽  
Vol 554-556 ◽  
pp. 926-933
Author(s):  
Zhi Rong Zhou ◽  
Li Zhen Zhang

A simple and sensitive kinetic spectrophotometric method for the determination of trace selenium (IV) is described, based on its catalytic effect on the reduction arsenazo III (AsA III) with sodium hypophosphite (NaH2PO2) in a solution of 0.02 mol/L sulfuric acid and in the presence of cationic micellar media. The reaction rate is monitored spectrophotometrically by measuring the decrease in absorbance of AsA III at 550 nm with a fixed-time method. The decrease in the absorbance of AsA III is proportional to the concentration of Se(IV) in the range 0.16–1.0 µg/L after a fixed time of 4–10 min from the initiation of the reaction. The limit of detection is 0.049 µg/L Se(IV). The influence of th e factors such as acidity, concentration of reactants, type and concentration of surfactants, reactive time, temperature and co-existing ions on the reaction is discussed. The optimum reaction conditions of reaction are established and some kinetic parameters are determined; the apparent activation energy of catalytic reaction is 59.51 kJ/mol. The relative standard deviation for eleven replicate determination of 0.02, and 0.01µg/25mL Se(IV) was 2.0 % and 2.4 %, respectively. Combined with sulphydryl dextrane gel (SDG) separation and enriching, the method has been successfully applied to the determination of Se (IV) in foodstuff and human hair samples with the relative standard deviation of 2.1 %–5.8 % and the recovery of 97.0 %–103.3 %, the results are in good agreement with those provided by ICP-AES method.


2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
César Soto ◽  
Cristian Poza ◽  
David Contreras ◽  
Jorge Yáñez ◽  
Fallon Nacaratte ◽  
...  

Amorolfine (AOF) is a compound with fungicide activity based on the dual inhibition of growth of the fungal cell membrane, the biosynthesis and accumulation of sterols, and the reduction of ergosterol. In this work a sensitive kinetic and spectrophotometric method for the AOF quantitation based on the AOF oxidation by means of KMnO4at 30 min (fixed time), pH alkaline, and ionic strength controlled was developed. Measurements of changes in absorbance at 610 nm were used as criterion of the oxidation progress. In order to maximize the sensitivity, different experimental reaction parameters were carefully studied via factorial screening and optimized by multivariate method. The linearity, intraday, and interday assay precision and accuracy were determined. The absorbance-concentration plot corresponding to tap water spiked samples was rectilinear, over the range of 7.56 × 10−6–3.22 × 10−5 mol L−1, with detection and quantitation limits of 2.49 × 10−6 mol L−1and 7.56 × 10−6 mol L−1, respectively. The proposed method was successfully validated for the application of the determination of the drug in the spiked tap water samples and the percentage recoveries were 94.0–105.0%. The method is simple and does not require expensive instruments or complicated extraction steps of the reaction product.


2014 ◽  
Vol 2014 ◽  
pp. 1-12 ◽  
Author(s):  
Mohammed G. Abdel Wahed ◽  
Ragaa El Sheikh ◽  
Ayman A. Gouda ◽  
Sayed Abou Taleb

Simple, sensitive, and accurate kinetic spectrophotometric method was proposed for the determination of gemifloxacin mesylate (GMF) and moxifloxacin hydrochloride (MOX) in pure forms and pharmaceutical preparations (tablets). The method is based on coupling the studied drugs with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) in the presence of alkaline borate buffer. Spectrophotometric measurement was achieved by recording the absorbance at 466 and 464 nm for GMF and MOX, respectively, after a fixed time of 20 and 15 min on a water bath adjusted at 70 ± 5°C for both drugs. The different experimental parameters affecting the development and stability of the color were carefully studied and optimized. The absorbance-concentration plots were linear over the ranges 0.5–8.0 and 2.0–12 μg mL−1for GMF and MOX, respectively. The limit of detection of the kinetic method was about 0.12 (2.47 × 10−7 M) and 0.36 (8.22 × 10−7 M) μg mL−1for GMF and MOX, respectively. The proposed methods have been applied and validated successfully with percentage relative standard deviation (RSD% ≤ 0.52) as precision and percentage relative error (RE% ≤ 1.33) as accuracy. The robustness of the proposed method was examined with recovery values that were 97.5–100.5 ± 1.3–1.9%. Statistical comparison of the results with the reference spectrophotometric methods shows excellent agreement and indicates no significant difference in accuracy or precision.


Sign in / Sign up

Export Citation Format

Share Document