PSV-4 Determination of Deoxynivalenol (DON) Content in Biological Samples as an Indicator of DON Intake in Grower-finisher Pigs

2021 ◽  
Vol 99 (Supplement_1) ◽  
pp. 206-207
Author(s):  
Michael O Wellington ◽  
Michael A Bosompem ◽  
Veronika Nagl ◽  
Daniel A Columbus

Abstract Due to difficulties in obtaining consistent and/or reliable measures of deoxynivalenol (DON) in complete swine diets, we investigated whether measuring DON in biological samples could be used as an indicator of DON ingestion in pigs. In this study, graded levels of DON (1, 3, or 5 ppm) were fed to grower-finisher pigs for a period of 77-d. On d 35 and 77 of the study, urine samples were quantitatively collected over a 24-h period and blood samples were collected between 3 – 4 h after the morning meal on each of those days for serum DON analysis. For direct quantification of DON in urine, high-performance liquid chromatography with tandem mass spectrometry was performed. For serum samples, indirect quantification of DON was performed via enzymatic hydrolysis. We observed that DON content in urine increased linearly as intake of DON increased (Fig.1A; P < 0.05). Analysis of DON in serum follow a similar trend, where serum DON content was increased as DON intake increased (Fig.1B; P < 0.05). An average of 30% of DON ingested was recovered as DON in urine over a 24-h period. In summary, there was a linear relationship between DON intake and DON content in both urine and blood serum, therefore, analyzing DON concentration in serum and urine could be used as a tool to estimate for DON exposure in pigs under controlled conditions.

2019 ◽  
Vol 43 (7) ◽  
pp. 579-586 ◽  
Author(s):  
Xiaoli Wang ◽  
Tao Guo ◽  
Yunbo Wei ◽  
Guiju Xu ◽  
Na Li ◽  
...  

Abstract Quinolone antibiotic residues may pose potential threat to human health. A rapid and sensitive method was developed for the determination of quinolone residues in human serum and urine. After solid phase extraction (SPE) process, eight quinolone residues were analyzed by high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) using ciprofloxacin-d8 as the internal standard. The relative standard deviation of intra-day and inter-day precision for the eight quinolones were less than 7.52% and the accuracies ranged from 95.8% to 103% in human serum, and from 94.1% to 104% in human urine. The extraction recoveries for the eight quinolones varied from 80.2% to 113% in human serum and 83.4% to 117% in human urine. The limit of detection for the eight quinolones was 0.50–1.00 ng/mL. Quinolone antibiotic residues in human serum and urine from 12 volunteers were successfully analyzed with the validated method. The SPE-HPLC-MS/MS method was useful for accurate determination of quinolone antibiotic residues in human body.


Molecules ◽  
2018 ◽  
Vol 23 (11) ◽  
pp. 2939 ◽  
Author(s):  
Min Liu ◽  
Zhi-Hui Yang ◽  
Guo-Hui Li

A novel, precise, and accurate high-performance liquid chromatography-tandem mass spectrometry (Q-trap-MS) method was developed, optimized, and validated for determination of vancomycin in human serum using norvancomycin as an internal standard. Effect of different parameters on the analysis was evaluated. ZORBAX SB-C18 column (150 × 4.6 mm, 5 μm) using water (containing 0.1% formic acid, v/v)–acetonitrile (containing 0.1% formic acid, v/v) as a mobile phase was chosen. The calibration curve was linear over the concentration ranges of 1 to 2000 ng/mL for vancomycin. The limit of detection (LOD) and limit of quantification (LOQ) for vancomycin were 0.3 and 1.0 ng/mL. Recoveries were between 87.2 and 102.3%, which gave satisfactory precision. A total of 100 serum samples (from 50 patients with diabetic foot proven Gram-positive infection and 50 nondiabetic patients with pneumonia requiring hospitalization and antibiotic therapy) were analyzed by this method. The trough vancomycin concentrations of diabetic foot infection (DFI) patients and nondiabetic patients were 8.20 ± 2.83 μg/mL (range: 4.80–14.2 μg/mL) and 15.80 ± 5.43 μg/mL (range: 8.60–19.5 μg/mL), respectively. The method is sensitive, precise, and reproducible, it could be applied for routine laboratory analysis of vancomycin in serum samples.


Sign in / Sign up

Export Citation Format

Share Document