scholarly journals Effects of Length on the Catchlike Property of Human Quadriceps Femoris Muscle

1999 ◽  
Vol 79 (8) ◽  
pp. 738-748 ◽  
Author(s):  
Samuel CK Lee ◽  
Michelle L Gerdom ◽  
Stuart A Binder-Macleod

Abstract Background and Purpose. Recent reports have suggested that electrical stimulation trains that take advantage of the catchlike property of skeletal muscle can produce higher forces from skeletal muscle than traditionally used constant-frequency trains. This study investigated the effects of catchlike-inducing trains on human quadriceps femoris muscles while the knee joint was held at 15 degrees of flexion. Subjects and Methods. Subjects (N=12) were tested with constant-frequency trains that had interpulse intervals ranging from 10 to 160 milliseconds and comparable catchlike-inducing trains. Data were collected during the control condition (1 train every 10 seconds) and during repetitive contractions (1 train per second). Results. During control and repetitive activation conditions, catchlike-inducing trains produced approximately 5% to 110% greater peak forces than comparable constant-frequency trains, depending on the frequencies being compared. Total forces produced (ie, force-time integrals) were increased up to 59% and 49% during the control and repetitive activation conditions, respectively. Conclusion and Discussion. These results support earlier findings that catchlike-inducing trains may be advantageous in functional electrical stimulation applications.

2018 ◽  
Vol 4 (1) ◽  
pp. e000381 ◽  
Author(s):  
Makoto Kawai ◽  
Keigo Taniguchi ◽  
Tomoyuki Suzuki ◽  
Masaki Katayose

ObjectivesOrthopaedic surgery of the knee joint results in functional deterioration of the quadriceps femoris muscle. However, little is known about quadriceps femoris muscle dysfunction in the early postsurgical period. Therefore, we examined the stiffness of the quadriceps femoris muscle in the early postsurgical period.MethodsSeven patients and seven healthy controls performed quadriceps contraction exercises. In resting and contraction conditions, the shear modulus, muscle thickness and pennation angle were measured for the vastus medialis (VM), vastus lateralis (VL) and the rectus femoris (RF) using ultrasound elastography.ResultsThe shear moduli of the VM, VL and RF in the control group did not significantly interact, while the shear moduli in the patient group did show a significant interaction. In the resting condition, there was no difference between the unaffected and affected sides in the patient group, but the shear moduli of the VM and VL in the contraction condition was significantly lower on the affected side than the unaffected side.The contraction ratios between muscles by limbs did not significantly interact. However, there were main effects due to muscle and limb factors. The VM and VL had a significantly higher contraction ratio than the RF, and the control and unaffected limbs had a higher contraction ratio than the affected limb.ConclusionThe results demonstrated a decrease in muscle stiffness during contraction in patients with quadriceps femoris dysfunction. Measurement of the shear modulus has potential as a new evaluation index and with high sensitivity to decreases in muscle contraction.


Author(s):  
Ryosuke Nakanishi ◽  
◽  
Minoru Tanaka ◽  
Noriaki Maeshige ◽  
Hidemi Fujino ◽  
...  

Background/Aims: This study investigated whether pulsed magnetic stimulation contracts superficial and/or deep muscles compared with those induced by electrical stimulations, i.e., low- and kilohertzfrequency currents. Methods: Eight healthy subjects were recruited and measured the quadriceps femoris muscle thickness using ultrasound imaging, and Visual Analog Scale (VAS) for stimulation-induced pain during the same stimulation intensity. Results: Pulsed magnetic stimulation increased the thickness of rectus femoris muscle similar to other electrical stimulations, but not the vastus intermedius muscle. Meanwhile, the pain score of VAS caused by pulsed magnetic stimulation was lower than that by those electrical stimulations. Conclusions: These results suggest that pulsed magnetic stimulation is effective for the contraction of superficial layer muscles without stimulation-induced pain but not for contraction of deep layer muscles. Keywords: pulsed magnetic stimulation; electrical stimulation; stimulation-induced pain; muscle contraction.


1956 ◽  
Vol 184 (2) ◽  
pp. 433-437 ◽  
Author(s):  
Leonard A. Cohen ◽  
Manfred L. Cohen

The knee joint of decerebrate cats was rotated through a full range of flexion-extension movements. The tensions of quadriceps femoris muscle and semitendinosus muscle were recorded and the responses of these muscles to joint movement were studied. The medial and posterior articular nerves were later sectioned and control records were taken. Flexion of the knee decreased the tension of quadriceps femoris but increased that of semitendinosus. Re-extension of the knee restored both tensions to their resting values. Data were obtained which showed that these responses were reflex in nature. Since the knee joint reflex is basically a slow adapting movement reflex, the name ‘arthrokinetic reflex’ seems appropriate. The activity of the arthrokinetic reflex indicates that its general function is to coordinate knee movement with other nervous activity in thigh muscles. In addition to this, the arthrokinetic reflex of the knee appears to have specific orientation toward dealing with the powerful stretch reflex of the quadriceps femoris muscle.


2001 ◽  
Vol 81 (7) ◽  
pp. 1307-1316 ◽  
Author(s):  
Yocheved Laufer ◽  
Julie Deanne Ries ◽  
Peter M Leininger ◽  
Gad Alon

Abstract Background and Purpose. Neuromuscular electrical stimulation is used by physical therapists to improve muscle performance. Optimal forms of stimulation settings are yet to be determined, as are possible sex-related differences in responsiveness to electrical stimulation. The objectives of the study were: (1) to compare the ability of 3 different waveforms to generate isometric contractions of the quadriceps femoris muscles of individuals without known impairments, (2) to compare muscle fatigue caused by repeated contractions induced by these same waveforms, and (3) to examine the effect of sex on muscle force production and fatigue induced by electrical stimulation. Subjects. Fifteen women and 15 men (mean age=29.5 years, SD=5.4, range=22–38) participated in the study. Methods. A portable battery-operated stimulator was used to generate either a monophasic or biphasic rectangular waveform. A stimulator that was plugged into an electrical outlet was used to generate a 2,500-Hz alternating current. Phase duration, frequency, and on-off ratios were kept identical for both stimulators. Participants did not know the type of waveform being used. Torque was measured using a computerized dynamometer: a maximal voluntary isometric contraction (MVIC) of the right quadriceps femoris muscle set at 60 degrees of knee flexion was determined during the first session. In each of the 3 testing sessions, torque of contraction and fatigue elicited by one waveform were measured. Order of testing was randomized. Torque elicited by electrical stimulation was expressed as a percentage of average MVIC. A mixed-model analysis of variance was used to determine the effect of stimulation and sex on strength of contraction and fatigue. Bonferroni-corrected post hoc tests were used to further distinguish between the effects of the 3 stimulus waveforms. Results. The results indicated that the monophasic and biphasic waveforms generated contractions with greater torque than the polyphasic waveform. These 2 waveforms also were less fatiguing. The torques from the maximally tolerated electrically elicited contractions were greater for the male subjects than for the female subjects. Discussion and Conclusion. Muscle torque and fatigue of electrically induced contractions depend on the waveform used to stimulate the contraction, with monophasic and biphasic waveforms having an advantage over the polyphasic waveform. All tested waveforms elicited, on average, stronger contractions in male subjects than in female subjects when measured as a percentage of MVIC.


2020 ◽  
Vol 5 (4) ◽  
pp. 98
Author(s):  
Yoshitsugu Tanino ◽  
Takaki Yoshida ◽  
Wataru Yamazaki ◽  
Yuki Fukumoto ◽  
Tetsuya Nakao ◽  
...  

The distal part of the vastus medialis (VM) (VM obliquus: VMO) muscle acts as the medial stabilizer of the patella. However, it has been known to facilitate VMO contraction during training of the quadriceps femoris muscle in knee joint rehabilitation. This study aimed to examine the contribution degree of VMO as a knee joint extension torque generator. Sixteen healthy male volunteers participated in this study. Electrical muscle stimulation (EMS) was performed on VMO at 60° knee angle for 20 min to induce muscle fatigue. Knee extension twitch torques (TT) at 90° and 30° knee angle evoked by femoral nerve stimulation were measured before and after EMS. Although each TT at 90° and 30° knee angle significantly decreased after EMS, the decreased TT rate in both joint angles showed no significant difference. Our results show that VMO might contribute to the generation of the knee joint torque at the same level in the range from flexion to extension. Therefore, it was suggested that the facilitating the neural drive for VMO is important during the quadriceps femoris muscle strengthening exercise.


Sign in / Sign up

Export Citation Format

Share Document