CONSOLIDATION OF A CROSS-ANISOTROPIC SOIL MEDIUM

1984 ◽  
Vol 37 (3) ◽  
pp. 479-495 ◽  
Author(s):  
J. R. BOOKER ◽  
M. F. RANDOLPH
Keyword(s):  
Author(s):  
I.V. Voytenko ◽  

Abstract. Strength anisotropy is characteristic of layered soil bases and has been confirmed by numerous tests. The relevance and novelty of this research is to study the effect of the seismic factor on the active pressure of the friable soil medium having strength anisotropy. A numerical experiment was carried out using a specially developed computer program, the algorithm of which used the method for determining the lateral pressure of a heterogeneous anisotropic soil, taking into account the seismic effect. The proposed method is based on the solutions of the classical theory of Coulomb, the seismic component is taken into account on the basis of the static theory of the earthquake stability of structures. We considered a vertically ideally smooth wall in contact with a two-layer incoherent soil medium, the anisotropy of the strength properties of which is represented by hodographs of friction angle. The layers are parallel, no surface load. A numerical research was to determine the parameters of the active pressure of the soil of the lower layer during rotation of the hodograph of friction angle with steps of 300. We used 4 hodographs: 1) φ1=150-200; 2) φ2=200-250; 3) φ3=250-300; 4) φ4=300-350 with a horizontal plane of isotropy. Seismic impact was taken into account by the seismicity coefficient, taken equal to depending on the scale 0.025 (7), 0.05 (8), 0.1 (9). The horizontal orientation of the seismic force and with an angle of 200 to the horizontal plane was set. The obtained results make it possible to evaluate the seismic effect on the lateral pressure of anisotropic soil by comparing it with the corresponding indicators obtained earlier without taking into account the seismic factor. An analysis of computer solutions indicates the increase of the active pressure in seismic conditions by 14%-45% compared with the same indicator, which was determined without taking into account the seismic factor.


2019 ◽  
Vol 6 (04) ◽  
Author(s):  
RAM PAL ◽  
H C SHARMA ◽  
M IMTIYAZ

The modern theme of agriculture is not only to increase production but also to minimize undesirable environmental effects. Leaching of surface-applied fertilizer is the major source of groundwater pollution. Nitrogenous fertilizers are the most popular among the Indian farmers, which on leaching reach the groundwater in different forms (NH4-N, NO3-N, etc). NO3-N leaches faster than other types, remains in-reactive in groundwater, moves with the velocity of groundwater and contaminates it. Contamination arises when NO3-N accumulates in groundwater and consumed in high amount by humans and animals, may result in adverse health effects. For the study of contaminant transport phenomenon in porous medium, a general convection dispersion equation is used, in which dispersion coefficient is one of the primary parameters necessary to be determined for a particular soil. Keeping it in view a study was conducted to assess different available techniques to determine the dispersion coefficient with the help of soil columns having silty loam soil as soil medium. The value of the dispersion coefficient obtained for silty loam soil, by this method was equal to 0.00576 m2.


2019 ◽  
Vol 2019 ◽  
pp. 1-9 ◽  
Author(s):  
V. Vázquez-Báez ◽  
A. Rubio-Arellano ◽  
D. García-Toral ◽  
I. Rodríguez Mora

We present a model of groundwater dynamics under stationary flow and, governed by Darcy’s law of water motion through porous media, we apply it to study a 2D aquifer with water table of constant slope comprised of a homogeneous and isotropic media; the more realistic case of an homogeneous anisotropic soil is also considered. Taking into account some geophysical parameters we develop a computational routine, in the Finite Difference Method, which solves the resulting elliptic partial equation, both in a homogeneous isotropic and in a homogeneous anisotropic media. After calibration of the numerical model, this routine is used to begin a study of the Ayamonte-Huelva aquifer in Spain, a modest analysis of the system is given, and we compute the average discharge vector as well as its root mean square as a first predictive approximation of the flux in this system, providing us a signal of the location of best exploitation; long term goal is to develop a complete computational tool for the analysis of groundwater dynamics.


2017 ◽  
Author(s):  
P. Tessy Chacko ◽  
N. R. Mahesh
Keyword(s):  

2012 ◽  
Vol 34 (4) ◽  
pp. 3-16 ◽  
Author(s):  
Karolina Gorska ◽  
Marek Wyjadłowski

Abstract The article presents back analysis to estimate geotechnical parameters of fill layer. The agreement between field measurements and theoretical calculations was examined. Displacements of a cantilever CFA bored pile wall were monitored. The inclinometric measurements were taken directly after pile construction and according to excavation process. Over 200 calculation series were performed, with changing fill parameters. The calculations employed the actual geometric and material parameters of the pile wall, as well as geotechnical parameters of layered soil. The parameters estimated through back analysis were the angle of internal friction and Young’s modulus of fill layer. In the case discussed, pile wall cap displacement was the response of the system, and soil medium parameters were the input data. The agreement between theoretical calculations and inclinometer measurements was assessed in accordance with two functions. The measured horizontal displacements of excavation support structure assumed different values at the two inclinometer sites analysed. Back analysis results for these sites are approximately convergent for a final excavation depth.


2021 ◽  
Vol 80 (13) ◽  
Author(s):  
Grzegorz Przydatek ◽  
Włodzimierz Kanownik

AbstractThe paper aims to determine the most significant physicochemical indicators of the effects that a lined landfill in southern Poland has had on groundwater quality. The results of the tests of groundwater and leachate water from the landfill for the period 2009 to 2016 were subjected to a detailed statistical analysis based on the 10 physicochemical parameters. A factor analysis was conducted considering the European Union and national requirements for landfills using analytical and statistical tools. The leachate contamination indicators from a landfill were analysed to reveal their interaction with the groundwater. The assessment indicated that there was an elevated and statistically significantly higher electrical conductivity and copper and total organic carbon concentrations in groundwater hydraulically downgradient of the landfill. The assessment also indicated that there were significant differences in the correlations between chemical parameters downgradient of the landfill and that there was a trend of increasing concentrations of some chemical constituents in groundwater. The adverse effects of the landfill were due to the deposited amount of waste exceeding 10 Mg per day. The impact was noticeable despite low and decreasing concentrations of heavy metals (Hg, Cu, Cd, Pb and Zn) in the leachate. The deterioration of the chemical state of the groundwater in the landfill vicinity could result in the extended time of pollutant migration or mass transport in the irrigated soil medium due to the limited efficiency of the leachate intake system or sealing screen after more than 20 years of landfill operation.


Sign in / Sign up

Export Citation Format

Share Document