LIFETIME LUNG CANCER RISKS ASSOCIATED WITH INDOOR RADON EXPOSURE BASED ON VARIOUS RADON RISK MODELS FOR CANADIAN POPULATION

2016 ◽  
Vol 173 (1-3) ◽  
pp. 252-258 ◽  
Author(s):  
Jing Chen
2006 ◽  
Vol 114 (9) ◽  
pp. 1361-1366 ◽  
Author(s):  
Olivier Catelinois ◽  
Agnès Rogel ◽  
Dominique Laurier ◽  
Solenne Billon ◽  
Denis Hemon ◽  
...  

Author(s):  
Katja Kojo ◽  
Päivi Kurttio

Background: Indoor radon exposure is the second leading cause of lung cancer. Finnish radiation legislation obligates employers to measure indoor radon concentrations in workplaces, including schools and daycare centers, if they are in radon prone areas. Surveillance campaigns were conducted to ensure that the required radon measurements were performed and to gain knowledge on current indoor radon levels in daycare centers and schools. Methods: Daycare centers located in the high-radon risk municipalities were identified. Schools where indoor radon level measurements were obligatory but not performed, were identified. Results: Indoor radon measurements were performed in 633 daycare centers where the mean radon concentration was 86 Bq/m3 and the median 40 Bq/m3. The radon level was greater than 300 Bq/m3 in 8% (n = 49) of daycare centers. The radon measurements were performed in 1176 schools, which is 95% of the schools to be measured. The mean radon concentration was 82 Bq/m3 and the median 41 Bq/m3. The radon levels were greater than 300 Bq/m3 in 14% (n = 169) of the schools. Conclusions: The systematic surveillance campaigns by the radiation protection authority were very efficient in order to ensure that the measurements are performed in schools and daycare centers. The campaigns also reduced the radon exposure of employees, children, and adolescents, where necessary.


Author(s):  
Jing Chen

AbstractFrom 2007 to 2013, simultaneous radon (222Rn) and thoron (220Rn) measurements were conducted in a total of 3534 residential homes in 34 metropolitan areas covering 71% of the Canadian population. While radon levels were above the detector’s detection limit in almost all homes, thoron concentrations were measurable in only 1738 homes. When analysis was limited to homes where thoron concentrations exceeded the detection limit, a pooled analysis confirmed that thoron is log-normally distributed in the indoor environment, and the distribution was characterized by a population-weighted geometric mean of 13 Bq/m3 and a geometric standard deviation of 1.89. Thoron contribution to indoor radon dose varied widely, ranging from 1.3 to 32% geographically. This study indicated that on average, thoron contributes 4% of the radiation dose due to total indoor radon exposure (222Rn and 220Rn) in Canada.


2012 ◽  
Vol 36 (1) ◽  
pp. e26-e32 ◽  
Author(s):  
Bárbara Veloso ◽  
José Rocha Nogueira ◽  
Margarida Fonseca Cardoso

Sign in / Sign up

Export Citation Format

Share Document