Use of 3D Planning and Patient-specific Guides for Proximal Humerus Corrective Osteotomy Associated With Shoulder Prosthesis Implantation in Proximal Humeral Varus Malunion

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Raffaele Russo ◽  
Andrea Cozzolino ◽  
Antonio Guastafierro ◽  
Giuseppe Della Rotonda ◽  
Stefano Viglione ◽  
...  
2018 ◽  
Vol 159 (45) ◽  
pp. 1838-1843
Author(s):  
Attila Szatmári ◽  
Balázs Benedek ◽  
Tamás Perlaky ◽  
Krisztián Szalay ◽  
Imre Sallai ◽  
...  

Abstract: Introduction: Several methods (bone graft, endoprosthesis) are used to reconstruct proximal humerus resections due to primary and metastatic tumours. One of the new procedures is the replacement of the joint surfaces and the removed proximal humerus end with reverse shoulder prosthesis, optionally supplemented with bone implantation (composite procedure) in the hope of achieving better shoulder function. Aim: The aim of this study was to compare the shoulder function of the patient group operated by the above procedure with reverse prosthesis to a patient group operated by indication of degenerative shoulder disease (rotator cuff arthropathy). Method: The study involved 23 patients (13 men, 10 women) who were operated between 2012 and 2016 in our institution. Among them, 15 had rotator cuff arthropathy indication of reverse prosthesis, while in 8 cases, resection of the humerus and prosthesis implantation were performed due to tumour lesions. The average age of our patients was 62.5 years (17–82) and the average follow-up was 23.5 months (5–57). We performed physical examination, X-ray pictures on their operated arm, and data were recorded and analysed based on functional score systems. Results: The level of postoperative pain was almost the same in the two groups, but only the rotator cuff arthropathy group needed pain medications. In line with our expectations, we received slightly lower values by each of the three scoring systems in case of tumorous patients. The tumorous patients were satisfied with the results achieved. Conclusions: Following proximal humerus resections, reversed prosthesis implantation with occasional bone allografts is a reliable method of reconstruction, which approaches available functions and reliability as compared to non-tumour-indicating patients. Orv Hetil. 2018; 159(45): 1838–1843.


Author(s):  
Sascha Beck ◽  
Theodor Patsalis ◽  
André Busch ◽  
Florian Dittrich ◽  
Alexander Wegner ◽  
...  

Abstract Introduction Stemmed humeral implants have represented the gold standard in total shoulder arthroplasty (TSA) for decades. Like many other joints, the latest trends in TSA designs aim at bone preservation. Current studies have demonstrated that native proximal humeral bone stresses are most closely mimicked by stemless implants. Nevertheless, there are concerns about the long-term performance of stemless designs. The aim of the present study was to evaluate the long-term radiographic changes at the proximal humerus in anatomical stemless press-fit TSA. Materials and Methods Between 2008 and 2010, 48 shoulders in 43 patients were resurfaced using an anatomic stemless shoulder prosthesis (TESS, Biomet). Thirty shoulders in twenty-five patients who were aged 65.7 ± 9.9 (34 to 82) years were available for clinical and radiographic review at a mean follow-up of 94.0 ± 8.9 (78 to 110) months. Results Radiographic changes of the proximal humerus due to stress shielding were found in 38.4% of the stemless TESS implants. Mild stress shielding accounted for 80% of the observed radiographic changes. Radiographs exhibited stable fixation of the stemless humeral press-fit implant at early and late follow-up. In contrast, radiolucent lines at the glenoid implant were found in 96.1% of the cases. Irrespective of the degree of radiographic changes, clinical scores (VAS, Quick-DASH, Constant score) significantly improved at follow-up. Conclusions The anatomic stemless press-fit implant seems to be favorable in terms of implant-related stress shielding. Clinical outcome was not affected by radiographic changes, demonstrating an 8-year clinical performance that seems to be comparable to conventional stemmed TSA.


2017 ◽  
Vol 26 (11) ◽  
pp. e357-e363 ◽  
Author(s):  
Maximiliano Ranalletta ◽  
Agustin Bertona ◽  
Juan M. Rios ◽  
Luciano A. Rossi ◽  
Ignacio Tanoira ◽  
...  

2018 ◽  
Vol 24 (1) ◽  
pp. 12-17 ◽  
Author(s):  
Lau Chi-Kay ◽  
Chui King-him ◽  
Lee Kin-bong ◽  
Li Wilson

Post-traumatic limb deformity is often multiplanar and thus is a difficult pathology to deal with surgically. Precise preoperative planning and accurate intraoperative execution are two main important steps that lead to satisfactory outcome. Computer-assisted planning and three-dimensional-printed patient-specific instrumental guides provide excellent aid to the two steps, respectively. We report a case of posttraumatic lower limb deformity in a patient who underwent closing wedge corrective osteotomy with the aid of the aforementioned new technologies.


2021 ◽  
Vol 8 ◽  
Author(s):  
Babak Saravi ◽  
Gernot Lang ◽  
Rebecca Steger ◽  
Andreas Vollmer ◽  
Jörn Zwingmann

Malunions of the upper extremity can result in severe functional problems and increase the risk of osteoarthritis. The surgical reconstruction of complex malunions can be technically challenging. Recent advances in computer-assisted orthopedic surgery provide an innovative solution for complex three-dimensional (3-D) reconstructions. This study aims to evaluate the clinical applicability of 3-D computer-assisted planning and surgery for upper extremity malunions. Hence, we provide a summary of evidence on this topic and highlight recent advances in this field. Further, we provide a practical implementation of this therapeutic approach based on three cases of malunited forearm fractures treated with corrective osteotomy using preoperative three-dimensional simulation and patient-specific surgical guides. All three cases, one female (56 years old) and two males (18 and 26 years old), had painful restrictions in range of motion (ROM) due to forearm malunions and took part in clinical and radiologic assessments. Postoperative evaluation of patient outcomes showed a substantial increase in range of motion, reduction of preoperatively reported pain, and an overall improvement of patients' satisfaction. The therapeutic approach used in these cases resulted in an excellent anatomical and functional reconstruction and was assessed as precise, safe, and reliable. Based on current evidence and our results, the 3-D preoperative planning technique could be the new gold standard in the treatment of complex upper extremity malunions in the future.


2019 ◽  
Vol 34 (4) ◽  
pp. 989-996
Author(s):  
Ivaylo Mitkovski

The proximal humerus is the third most common fracture location in elderly patients after the proximal femoral bone and the distal radial bone. In order to restore the anatomy and bring it as close to normal as possible, blood reposition with internal fixation is a method of choice for unstable fractures. However, surgical treatment is difficult and problematic because of disturbed approach to the fracture and the large fragmentation of pieces. A proximal shoulder bone fracture, which disturbs blood supply of the humeral head, may require placement of prosthesis. Hemiarthroplasty is a logical attitude in such cases, but analysis of functional results and complications has identified a certain number of risk factors limiting indications. Strict analysis of patient characteristics and of fracture type is an essential prerequisite to deciding against treatment by immobilization or osteosynthesis. Results in hemiarthroplasty are primarily dependent on respecting the rules of the art, which aim at stable anatomic osteosynthesis of the surrounding structures so as to restore normal shoulder function. The critical steps are the adjustment of implant height and retroversion, reduction and fixation of tuberosities and good management of the postoperative course. The recent development of fracture-dedicated shoulder implants should improve results. In elderly patients, when local conditions are unsuitable to hemiarthroplasty, a reverse prosthesis may be used, with an adapted surgical technique. Whatever the type of prosthesis, implantation for proximal humerus fracture is a demanding operation with definitive impact on the functional evolution of the shoulder. Following reports of results for shoulder prosthesis in proximal humerus fracture from 1970, several attempts were made to reproduce the encouraging initial findings. Most found good results in terms of pain, but much less satisfactory functional outcome. Analyzing the causes of failure identified risk factors and enabled solutions to be suggested. Among these, one of the first was to select indications, eliminating baseline situations of poor prognosis. Following good results reported in arthropathy involving rotator cuff tear and in revision of hemiarthroplasty for fracture, reverse prostheses were recommended as an alternative attitude in case of proximal humerus fracture in elderly subjects. This particular indication is currently under assessment.This article presents results of a 3-year experience in shoulder endoprothesis after fracture of proximal humerus in elderly patients at Orthopaedics and Traumatology Department, St. Anna General Active Treatment Hospital – Varna, between 2016 and 2018. In this time period, 79 shoulder endoprothesis have been implanted, 68 of which have been actively and carefully observed in the first 12 months of the post-surgery recovery. For the treatment of functional results was utilized Constant Shoulder Score (CSS) that aided following patients’ condition, pain levels, as well as functioning and shoulder movements. Results suggest that in the time span of one year, 51% of the patients show excellent overall recovery state and 38% are in good overall recovery state. These fine results of post-surgery shoulder functioning are in large part due to precise surgery techniques and detailed pre-surgical diagnosis and planning.


Sign in / Sign up

Export Citation Format

Share Document