scholarly journals Modafinil and γ-hydroxybutyrate have sleep state-specific pharmacological actions on hypocretin-1 physiology in a primate model of human sleep

2009 ◽  
Vol 20 (7) ◽  
pp. 643-652 ◽  
Author(s):  
Jamie M. Zeitzer ◽  
Christine L. Buckmaster ◽  
Hans-Peter Landolt ◽  
David M. Lyons ◽  
Emmanuel Mignot
Author(s):  
Yuki Wakuda ◽  
◽  
Akiko Noda ◽  
Yasuhisa Hasegawa ◽  
Fumihito Arai ◽  
...  

This research aimed to observe human biological rhythm and adjust the human sleep wake pattern based on controlling wakeup timing using low stress system. An ordinary alarm clock operates according to preset time. Biological rhythm determines the human sleep cycle, which affects sleep depth and wakeup timing, which in turn resets the daily rhythm that affects human’s behavior, life-cycle pattern, life-style related disease. We developed a wearable biological rhythm based awakening controller (BRAC) that determines the biological rhythm in the sleep state (sleep cycle) and stimulates the user at a suitable time to enable the person to wakeup refreshed. The proposed system BRAC gauges human’s sleep quality and rhythms from peak to peak interval time of fingertip-pulse waves, that are measured more easily than polysomnography (PSG). In this paper, we detail the method of sleep cycle estimation using a wearable sensor device as the first feature of BRAC, then, in experiments, evaluate the performance of sleep cycle estimation based on a comparison of the BRAC-sleep cycle and the PSG-determined sleep stage.


Author(s):  
A. Singh ◽  
A. Dykeman ◽  
J. Jarrelf ◽  
D. C. Villeneuve

Hexachlorobenzene (HCB), a persistent and mobile organochlorine pesticide, occurs in environment. HCB has been shown to be present in human follicular fluid. An objective of the present report, which is part of a comprehensive study on reproductive toxicity of HCB, was to determine the cytologic effects of the compound on ovarian follicles in a primate model.Materials and Methods. Eight Cynomolgus monkeys were housed under controlled conditions at Animal facility of Health and Welfare, Ottawa. Animals were orally administered gelatin capsules containing HCB mixed with glucose in daily dosages of 0.0 or 10 mg/kg b.w. for 90 days; the former was the control group. On the menstrual period following completion of dosing, the monkeys underwent an induction cycle of superovulation. At necropsy, one-half of an ovary from each animal was diced into ca. 2- to 3-mm cubed specimens that were fixed by immersion in 2.5% glutaraldehyde in 0.1 M cacodylate buffer (pH 7.3). Subsequent procedures followed to obtain thin sections that were examined in a Hitachi H-7000 electron microscope have been described earlier.


2001 ◽  
Vol 120 (5) ◽  
pp. A167-A167
Author(s):  
R ZIMMER ◽  
P THOMAS ◽  
N CLAPP ◽  
C STANNERS ◽  
M TOBI ◽  
...  

1971 ◽  
Vol 127 (3) ◽  
pp. 484a-492
Author(s):  
M. W. Johns
Keyword(s):  

Diabetes ◽  
2018 ◽  
Vol 67 (Supplement 1) ◽  
pp. 222-OR
Author(s):  
MICHAEL J. NASH ◽  
TAYLOR K. SODERBORG ◽  
RACHEL C. JANSSEN ◽  
ERIC M. PIETRAS ◽  
JACOB E. FRIEDMAN

2004 ◽  
pp. 373-380 ◽  
Author(s):  
Timothy D. Solberg ◽  
Steven J. Goetsch ◽  
Michael T. Selch ◽  
William Melega ◽  
Goran Lacan ◽  
...  

Object. The purpose of this work was to investigate the targeting and dosimetric characteristics of a linear accelerator (LINAC) system dedicated for stereotactic radiosurgery compared with those of a commercial gamma knife (GK) unit. Methods. A phantom was rigidly affixed within a Leksell stereotactic frame and axial computerized tomography scans were obtained using an appropriate stereotactic localization device. Treatment plans were performed, film was inserted into a recessed area, and the phantom was positioned and treated according to each treatment plan. In the case of the LINAC system, four 140° arcs, spanning ± 60° of couch rotation, were used. In the case of the GK unit, all 201 sources were left unplugged. Radiation was delivered using 3- and 8-mm LINAC collimators and 4- and 8-mm collimators of the GK unit. Targeting ability was investigated independently on the dedicated LINAC by using a primate model. Measured 50% spot widths for multisource, single-shot radiation exceeded nominal values in all cases by 38 to 70% for the GK unit and 11 to 33% for the LINAC system. Measured offsets were indicative of submillimeter targeting precision on both devices. In primate studies, the appearance of an magnetic resonance imaging—enhancing lesion coincided with the intended target. Conclusions. Radiosurgery performed using the 3-mm collimator of the dedicated LINAC exhibited characteristics that compared favorably with those of a dedicated GK unit. Overall targeting accuracy in the submillimeter range can be achieved, and dose distributions with sharp falloff can be expected for both devices.


Sign in / Sign up

Export Citation Format

Share Document