scholarly journals The influence of artificial nucleus pulposus replacement on stress distribution in the cartilaginous endplate in a 3-dimensional finite element model of the lumbar intervertebral disc

Medicine ◽  
2017 ◽  
Vol 96 (50) ◽  
pp. e9149 ◽  
Author(s):  
Yu Wang ◽  
Xiao-Dong Yi ◽  
Chun-De Li
2003 ◽  
Vol 15 (02) ◽  
pp. 82-85 ◽  
Author(s):  
SHYH-CHOUR HUANG ◽  
CHANG-FENG TSAI

This paper presents results from using a 3-dimensional finite element model to assess the stress distribution in the bone, in the implant and in the abutment as a function of the implant's diameter and length. Increasing implant diameter and length increases the stability of the implant system. By using a finite element analysis, we show that implant length does not decrease the stress distribution of either the implant or the bone. Alternatively, however implant diameter increases reduce the stresses. For the latter case, the contact area between implant and bone is increased thus the stress concentration effect is decreased. Also, with increased implant diameter the bone loss is decreased and as a consequence the success rate is improved.


PLoS ONE ◽  
2017 ◽  
Vol 12 (5) ◽  
pp. e0177088 ◽  
Author(s):  
Gloria Casaroli ◽  
Fabio Galbusera ◽  
René Jonas ◽  
Benedikt Schlager ◽  
Hans-Joachim Wilke ◽  
...  

2009 ◽  
Vol 131 (12) ◽  
Author(s):  
Feng Xie ◽  
Liu Yang ◽  
Lin Guo ◽  
Zhi-jun Wang ◽  
Gang Dai

To establish a finite element model that reflects the geometric characteristics of the normal anterior cruciate ligament (ACL), explore the approaches to model knee joint ligaments and analyze the mechanics of the model. A healthy knee joint specimen was subjected to three-dimensional laser scanning, and then a three-dimensional finite element model for the normal ACL was established using three-dimensional finite element software. Based on the model, the loads of the ACL were simulated to analyze the stress-strain relationship and stress distribution of the ACL. Using the ABAQUS software, a three-dimensional finite element model was established. The whole model contained 22,125 nodes and 46,411 units. In terms of geometric similarity and mesh precision, this model was superior to previous finite element models for the ACL. Through the introduction of material properties, boundary conditions, and loads, finite elements were analyzed and computed successfully. The relationship between overall nodal forces and the displacement of the ACL under anterior loads of the tibia was determined. In addition, the nephogram of the ACL stress spatial distribution was obtained. A vivid, three-dimensional model of the knee joint was established rapidly by using reverse engineering technology and laser scanning. The three-dimensional finite element method can be used for the ACL biomechanics research. The method accurately simulated the ACL stress distribution with the tibia under anterior loads, and the computational results were of clinical significance.


Sign in / Sign up

Export Citation Format

Share Document