Temporal and spatial properties of fluctuations below a supercritical primary bifurcation to traveling oblique-roll electroconvection

2002 ◽  
Vol 65 (5) ◽  
Author(s):  
Michael A. Scherer ◽  
Guenter Ahlers
Author(s):  
R. C. Bulow ◽  
C. L. Johnson ◽  
B. G. Bills ◽  
P. M. Shearer

2020 ◽  
Vol 12 (1) ◽  
pp. 171
Author(s):  
Maria Lanfredi ◽  
Rosa Coluzzi ◽  
Vito Imbrenda ◽  
Maria Macchiato ◽  
Tiziana Simoniello

Seasonality is a fundamental feature of environmental systems which critically depend on the climate annual cycle. The regularity of the precipitation regime, in particular, is a basic factor to sustain equilibrium conditions. An incomplete or biased understanding of precipitation seasonality, in terms of temporal and spatial properties, could severely limit our ability to respond to climate risk, especially in areas with limited water resources or fragile ecosystems. Here, we analyze precipitation data from the Climate Hazards Group Infrared Precipitation with Stations (CHIRPS) at 0.050 resolution to study the spatial features of the precipitation seasonality across different climate zones in Central-Southern Europe during the period 1981–2018. A cluster analysis of the average annual precipitation cycle shows that seasonality under the current climate can be synthesized in the form of a progressive deformation process of the annual cycle, which starts from the northernmost areas with maximum values in summer and ends in the south, where maximum values are recorded in winter. Our analysis is useful to detect local season-dependent changes, enhancing our understanding of the geography of climate change. As an example of application to this issue, we discuss the seasonality analysis in a simulated scenario based on IPCC projections.


2018 ◽  
Author(s):  
Maria Laura Filippetti ◽  
Louise P. Kirsch ◽  
Laura Crucianelli ◽  
Aikaterini Fotopoulou

AbstractOur sense of body ownership relies on integrating different sensations according to their temporal and spatial congruency. Nevertheless, there is ongoing controversy about the role of affective congruency during multisensory integration, i.e. whether the stimuli to be perceived by the different sensory channels are congruent or incongruent in terms of their affective quality. In the present study, we applied a widely used multisensory integration paradigm, the Rubber Hand Illusion, to investigate the role of affective, top-down aspects of sensory congruency between visual and tactile modalities in the sense of body ownership. In Experiment 1 (N = 36), we touched participants with either soft or rough fabrics in their unseen hand, while they watched a rubber hand been touched synchronously with the same fabric or with a ‘hidden’ fabric of ‘uncertain roughness’. In Experiment 2 (N = 50), we used the same paradigm as in Experiment 1, but replaced the ‘uncertainty’ condition with an ‘incongruent’ one, in which participants saw the rubber hand being touched with a fabric of incongruent roughness and hence opposite valence. We found that certainty (Experiment 1) and congruency (Experiment 2) between the felt and vicariously perceived tactile affectivity led to higher subjective embodiment compared to uncertainty and incongruency, respectively, irrespective of any valence effect. Our results suggest that congruency in the affective top-down aspects of sensory stimulation is important to the multisensory integration process leading to embodiment, over and above temporal and spatial properties.


Psychology ◽  
2013 ◽  
Vol 04 (08) ◽  
pp. 663-668 ◽  
Author(s):  
Holger Hoffmann ◽  
Harald C. Traue ◽  
Kerstin Limbrecht-Ecklundt ◽  
Steffen Walter ◽  
Henrik Kessler

2005 ◽  
Vol 288 (6) ◽  
pp. R1756-R1766 ◽  
Author(s):  
Holly A. Shiels ◽  
Ed White

Confocal microscopy was used to investigate the temporal and spatial properties of Ca2+ transients and Ca2+ sparks in ventricular myocytes of the rainbow trout ( Oncorhynchus mykiss). Confocal imaging confirmed the absence of T tubules and the long (∼160 μm), thin (∼8 μm) morphology of trout myocytes. Line scan imaging of Ca2+ transients evoked by electrical stimulation in cells loaded with fluo 4 revealed spatial inhomogeneities in the temporal properties of Ca2+ transients across the width of the myocytes. The Ca2+ wavefront initiated faster, rose faster, and reached larger peak amplitudes in the periphery of the myocyte compared with the center. These differences were exacerbated by stimulation with the L-type Ca2+ channel agonist (−)BAY K 8644 or by sarcoplasmic reticulum (SR) inhibition with ryanodine and thapsigargin. Results reveal that the shape of the trout myocyte allows for rapid diffusion of Ca2+ from the cell periphery to the cell center, with SR Ca2+ release contributing to the cytosolic Ca2+ rise in a time-dependent manner. Spontaneous Ca2+ sparks were exceedingly rare in trout myocytes under control conditions (1 sparking cell from 238 cells examined). This is in marked contrast to the rat where a total of 56 spontaneous Ca2+ sparks were observed in 9 of 11 myocytes examined. Ca2+ sparklike events were observed in a very small number of trout myocytes (15 sparks from 9 of 378 cells examined) after stimulation with either (−)BAY K 8644 or high Ca2+ (6 mM). Reducing temperature to 15°C in intact myocytes or permeabilizing myocytes to adjust intracellular conditions to favor Ca2+ spark detection was without significant effects. Possible reasons for the rarity of Ca2+ sparks in a cardiac myocyte with an active SR are discussed.


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
Chung-Shing Hu ◽  
Yu-Feng Chung ◽  
Cheng-Chang Yeh ◽  
Ching-Hsing Luo

Conventionally, a pulse taking platform is based on a single sensor, which initiates a feasible method of quantitative pulse diagnosis. The aim of this paper is to implement a pulse taking platform with a tactile array sensor. Three-dimensional wrist pulse signals are constructed, and the length, width, ascending slope, and descending slope are defined following the surface of the wrist pulse. And the pressure waveform of the wrist pulse obtained through proposed pulse-taking platform has the same performance as the single sensor. Finally, the results of a paired samplest-test reveal that the repeatability of the proposal platform is consistent with clinical experience. On the other hand, the results of ANOVA indicate that differences exist among different pulse taking depths, and this result is consistent with clinical experience in traditional Chinese medicine pulse diagnosis (TCMPD). Hence, the proposed pulse taking platform with an array sensor is feasible for quantification in TCMPD.


Sign in / Sign up

Export Citation Format

Share Document