Notice of Retraction: Research on Heat Transfer Enhancement of Lubricating-Oil Cooler with Mixing Integral Pin-Fin Tubes and Plain Tubes

Author(s):  
Guang-lin Niu ◽  
Chang-qi Yan ◽  
Shuai Shi
2011 ◽  
Vol 134 (1) ◽  
Author(s):  
Hafiz Muhammad Ali ◽  
Adrian Briggs

This paper presents a fundamental study into the underlying mechanisms influencing heat transfer during condensation on enhanced surfaces. New experimental data are reported for condensation of ethylene glycol at near atmospheric pressure and low velocity on 11 different 3-dimensional pin-fin tubes tested individually. Enhancements of the vapor-side, heat-transfer coefficients were found between 3 and 5.5 when compared to a plain tube at the same vapor-side temperature difference. Heat-transfer enhancement was found to be strongly dependent on the active surface area of the tubes, i.e., on the surface area of the parts of the tube and pin surface not covered by condensate retained by surface tension. For all the tubes, vapor-side, heat-transfer enhancements were found to be approximately twice the corresponding active-area enhancements. The best performing pin-fin tube gave a heat-transfer enhancement of 5.5; 17% higher than obtained from “optimised” two-dimensional fin-tubes reported in the literature and about 24% higher than the “equivalent” two-dimensional integral-fin tube (i.e., with the same fin-root diameter, longitudinal fin spacing and thickness, and fin height). The effects of surface area and surface tension induced enhancement and retention are discussed in the light of the new data and those of previous investigations.


Author(s):  
Hafiz Muhammad Ali ◽  
Hassan Ali ◽  
Adrian Briggs

New experimental data are reported for condensation of ethylene glycol at near atmospheric pressure and low velocity on six three-dimensional pin-fin tubes. Enhancements of the vapour-side, heat-transfer coefficients were found between 3 to 5.5 when compared to a plain tube at the same vapour-side temperature difference. Heat-transfer enhancement was found to be strongly dependent on the active surface area i.e. on the proportion of the tube and pin surface not covered by condensate retained by surface tension. For all the tubes, vapour-side, heat-transfer enhancements were found to be approximately 3 times the corresponding active-area enhancements. The best performing pin-fin tube gave a heat-transfer enhancement of up to 5.5; 17% higher than those obtained from ‘optimised’ two-dimensional fin-tubes reported in the literature and about 24% higher than the ‘equivalent’ two-dimensional integral-fin tube (i.e. with same fin root diameter, longitudinal fin spacing and thickness and fin height).


Fluids ◽  
2021 ◽  
Vol 6 (1) ◽  
pp. 25
Author(s):  
Iris Gerken ◽  
Thomas Wetzel ◽  
Jürgen J. Brandner

Micro heat exchangers have been revealed to be efficient devices for improved heat transfer due to short heat transfer distances and increased surface-to-volume ratios. Further augmentation of the heat transfer behaviour within microstructured devices can be achieved with heat transfer enhancement techniques, and more precisely for this study, with passive enhancement techniques. Pin fin geometries influence the flow path and, therefore, were chosen as the option for further improvement of the heat transfer performance. The augmentation of heat transfer with micro heat exchangers was performed with the consideration of an improved heat transfer behaviour, and with additional pressure losses due to the change of flow path (pin fin geometries). To capture the impact of the heat transfer, as well as the impact of additional pressure losses, an assessment method should be considered. The overall exergy loss method can be applied to micro heat exchangers, and serves as a simple assessment for characterization. Experimental investigations with micro heat exchanger structures were performed to evaluate the assessment method and its importance. The heat transfer enhancement was experimentally investigated with microstructured pin fin geometries to understand the impact on pressure loss behaviour with air.


Author(s):  
Wei Li ◽  
Dan Huang ◽  
Zan Wu ◽  
Hong-Xia Li ◽  
Zhao-Yan Zhang ◽  
...  

An experimental investigation was performed for convective condensation of R410A inside four micro-fin tubes with the same outside diameter (OD) 5 mm and helix angle 18°. Data are for mass fluxes ranging from about 180 to 650 kg/m2s. The nominal saturation temperature is 320 K, with inlet and outlet qualities of 0.8 and 0.1, respectively. The results suggest that Tube 4 has the best thermal performance for its largest condensation heat transfer coefficient and relatively low pressure drop penalty. Condensation heat transfer coefficient decreases at first and then increases or flattens out gradually as G decreases. This complex mass-flux effect may be explained by the complex interactions between micro-fins and fluid. The heat transfer enhancement mechanism is mainly due to the surface area increase over the plain tube at large mass fluxes, while liquid drainage and interfacial turbulence play important roles in heat transfer enhancement at low mass fluxes. In addition, the experimental data was analyzed using seven existing pressure-drop and four heat-transfer models to verify their respective accuracies.


1999 ◽  
Vol 121 (4) ◽  
pp. 972-977 ◽  
Author(s):  
F.-C. Chou ◽  
J. R. Lukes ◽  
C.-L. Tien

The current literature contains many studies of microchannel and micro-pin-fin heat exchangers, but none of them consider the size effect on the thermal conductivity of channel and fin walls. The present study analyzes the effect of size (i.e., the microscale effect) on the microfin performance, particularly in the cryogenic regime where the microscale effect is often appreciable. The size effect reduces the thermal conductivity of microchannel and microfin walls and thus reduces the heat transfer rate. For this reason, heat transfer enhancement by microfins becomes even more important than for macroscale fins. The need for better understanding of heat transfer enhancement by microfins motivates the current study, which resolves three basic issues. First, it is found that the heat, flow choking can occur even in the case of simple plate fins or pin fins in the microscale regime, although choking is usually caused by the accommodation of a cluster of fins at the fin tip. Second, this paper shows that the use of micro-plate-fin arrays yields a higher heat transfer enhancement ratio than the use of the micro-pin-fin arrays due to the stronger reduction of thermal conductivity in micro-pin-fins. The third issue is how the size effect influences the fin thickness optimization. For convenience in design applications, an equation for the optimum fin thickness is established which generalizes the case without the size effect as first reported by Tuckerman and Pease.


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Sin Chien Siw ◽  
Minking K. Chyu ◽  
Tom I.-P. Shih ◽  
Mary Anne Alvin

Heat transfer and pressure characteristics in a rectangular channel with pin-fin arrays of partial detachment from one of the endwalls have been experimentally studied. The overall channel geometry (W = 76.2 mm, E = 25.4 mm) simulates an internal cooling passage of wide aspect ratio (3:1) in a gas turbine airfoil. With a given pin diameter, D = 6.35 mm = ¼E, three different pin-fin height-to-diameter ratios, H/D = 4, 3, and 2, were examined. Each of these three cases corresponds to a specific pin array geometry of detachment spacing (C) between the pin tip and one of the endwalls, i.e., C/D = 0, 1, 2, respectively. The Reynolds number, based on the hydraulic diameter of the unobstructed cross-section and the mean bulk velocity, ranges from 10,000 to 25,000. The experiment employs a hybrid technique based on transient liquid crystal imaging to obtain the distributions of the local heat transfer coefficient over all of the participating surfaces, including the endwalls and all the pin elements. Experimental results reveal that the presence of a detached space between the pin tip and the endwall has a significant effect on the convective heat transfer and pressure loss in the channel. The presence of pin-to-endwall spacing promotes wall-flow interaction, generates additional separated shear layers, and augments turbulent transport. In general, an increase in detached spacing, or C/D, leads to lower heat transfer enhancement and pressure drop. However, C/D = 1, i.e., H/D = 3, of a staggered array configuration exhibits the highest heat transfer enhancement, followed by the cases of C/D = 0 and C/D = 2, i.e., H/D = 4 or 2, respectively.


Sign in / Sign up

Export Citation Format

Share Document